研究纳入39例慢性肝病患者的44个肝病灶,由两名放射科医生独立使用LI-RADS量表、另两名使用Likert量表分析MRI图像,以组织病理学或4年MRI随访为参考标准。LI-RADS量表准确率80%、敏感度72%、特异度93%、阳性预测值93%、阴性预测值70%,Likert量表分别为79%、73%、87%、89%、70%;AUC分别为85%和83%。两量表性能无统计学显著差异,但作者建议使用LI-RADS量表,因其显得更客观和一致。

要点

  • LI-RADS v.2018量表在慢性肝病肝结节MRI特征分析中准确率80%、敏感度72%、特异度93%。
  • LI-RADS量表观察者间一致性强(k=0.89),Likert量表为中等(k=0.69)。
  • 两量表性能无统计学显著差异,但作者建议使用LI-RADS量表,因其显得更客观和一致。

核心结论

  • 两量表性能无统计学显著差异,但作者建议使用LI-RADS量表,因其显得更客观和一致。

研究设计与样本

  • 共39例慢性肝病患者因44个肝病灶的特征分析接受MR检查,图像由两名放射科医生独立使用LI-RADS量表分析、另两名使用Likert量表分析,参考标准为组织病理学评估或4年MRI随访,并进行了受试者工作特征分析。

诊断标准与关键数值

  • LI-RADS量表准确率80%、敏感度72%、特异度93%、阳性预测值93%、阴性预测值70%,AUC为85%。
  • Likert量表准确率79%、敏感度73%、特异度87%、阳性预测值89%、阴性预测值70%,AUC为83%。
  • LI-RADS评估者间一致性强(k=0.89),Likert评估者间一致性中等(k=0.69)。

临床应用与阅片要点

  • 作者建议使用LI-RADS量表,因其显得更客观和一致。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the performance of the LI-RADS v.2018 scale by comparing it with the Likert scale, in the characterization of liver lesions.

METHODS: A total of 39 patients with chronic liver disease underwent MR examination for characterization of 44 liver lesions. Images were independently analyzed by two radiologists using the LI-RADS scale and by another two radiologists using the Likert scale. The reference standard used was either histopathological evaluation or a 4-year MRI follow-up. Receiver operating characteristic analysis was performed.

RESULTS: The LI-RADS scale obtained an accuracy of 80%, a sensitivity of 72%, a specificity of 93%, a positive predictive value (PPV) of 93% and a negative predictive value (NPV) of 70%, while the Likert scale achieved an accuracy of 79%, a sensitivity of 73%, a specificity of 87%, a PPV of 89% and a NPV of 70%. The area under the curve (AUC) was 85% for the LI-RADS scale and 83% for the Likert scale. The inter-observer agreement was strong (k = 0.89) between the LI-RADS evaluators and moderate (k = 0.69) between the Likert evaluators.

CONCLUSIONS: There was no statistically significant difference between the performances of the two scales; nevertheless, we suggest that the LI-RADS scale be used, as it appeared more objective and consistent.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Esposito A, Buscarino V, Raciti D, et al. Characterization of liver nodules in patients with chronic liver disease by MRI: performance of the Liver Imaging Reporting and Data System (LI-RADS v.2018) scale and its comparison with the Likert scale. Radiol Med. 2019. PMID: 31587182. doi:10.1007/s11547-019-01092-y