文献速递腹部技术与安全CT

CT碘对比剂较低剂量与注射速度同急性超敏反应的关系:一项观察性研究

Relationship between Lower Dose and Injection Speed of Iodinated Contrast Material for CT and Acute Hypersensitivity Reactions: An Observational Study.
PubMed 文献 · Radiology · 2019-10-15

该回顾性研究纳入2016年8月至2017年1月(对照期)及2017年8月至2018年1月(干预期)在门诊行非离子型碘对比剂增强腹部CT的成人,比较两期急性超敏反应率。干预期采用100 kVp、1.5 mL/kg(最大130 mL)、注射速度2.5或3 mL/sec,对照期采用120 kVp、2 mL/kg(最大150 mL)、注射速度3或4 mL/sec。干预期急性超敏反应率为1.42%(376/26491),低于对照期的1.86%(468/25119),多变量校正相对危险度为0.85(95%CI:0.74,0.99;P=.03)。

要点

  • 干预期急性超敏反应率为1.42%(376/26491次检查),对照期为1.86%(468/25119次检查)。
  • 多变量校正相对危险度为0.85(95%CI:0.74,0.99;P=.03),提示降低对比剂剂量与注射速度与较低急性超敏反应率相关。
  • 干预方案为100 kVp、1.5 mL/kg(最大130 mL)、注射速度2.5或3 mL/sec,对照方案为120 kVp、2 mL/kg(最大150 mL)、注射速度3或4 mL/sec。

核心结论

  • 降低CT碘对比剂的剂量和注射速度与较低的急性超敏反应率相关(多变量校正相对危险度0.85,95%CI:0.74,0.99;P=.03)。

研究设计与样本

  • 回顾性观察性研究,纳入2016年8月至2017年1月(对照期)和2017年8月至2018年1月(干预期)在门诊行非离子型碘对比剂增强腹部CT的成人(年龄≥18岁)。
  • 对照期共21947名成人(平均年龄59岁±12;女性8797名[40%])完成25119次CT检查。
  • 干预期共23019名成人(平均年龄59岁±12;女性9538名[41%])完成26491次CT检查。
  • 对照期CT参数:管电压120 kVp,对比剂剂量2 mL/kg(最大150 mL),注射速度3或4 mL/sec。
  • 干预期CT参数:管电压100 kVp,对比剂剂量1.5 mL/kg(最大130 mL),注射速度2.5或3 mL/sec。

诊断标准与关键数值

  • 急性超敏反应率:干预期为1.42%(376/26491次检查;95%CI:1.28%,1.57%),对照期为1.86%(468/25119次检查;95%CI:1.70%,2.04%)。
  • 多变量校正相对危险度为0.85(95%CI:0.74,0.99;P=.03),干预期相对于对照期。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BackgroundThere are few data on the relationship between acute hypersensitivity reactions and the dose and injection rate of iodinated contrast material for CT.PurposeTo determine the relationship between lower dose and injection speed of iodinated contrast material for CT and the rate of acute hypersensitivity reactions.Materials and MethodsThis retrospective study included adults (age ≥18 years) undergoing nonionic iodinated contrast material-enhanced abdominal CT between August 2016 and January 2017 (control period) and between August 2017 and January 2018 (intervention period); all examinations were conducted in an outpatient setting. Compared with CT during the control period, CT during the intervention period involved a reduced dose of contrast material achieved by lowering the CT tube voltage. CT examinations in the control period were performed with 120 kVp, a contrast material dose of 2 mL/kg (maximum, 150 mL), and an injection speed of 3 or 4 mL/sec. CT examinations in the intervention period were performed with 100 kVp, a contrast material dose of 1.5 mL/kg (maximum, 130 mL), and an injection speed of 2.5 or 3 mL/sec. Per-examination rates of acute hypersensitivity reactions to iodinated contrast material were compared between the control and intervention periods with use of a multivariable Poisson regression model, the parameters of which were estimated by using generalized estimating equations with an independence correlation structure.ResultsA total of 21947 adults (mean age ± standard deviation, 59 years ± 12; 8797 women [40%]) underwent 25119 CT examinations during the control period; 23019 adults (mean age, 59 years ± 12; 9538 women [41%]) underwent 26491 CT examinations during the intervention period. The rate of acute hypersensitivity reactions was 1.42% (376 of 26491 examinations; 95% confidence interval [CI]: 1.28%, 1.57%) in the intervention period and 1.86% (468 of 25119 examinations; 95% CI: 1.70%, 2.04%) in the control period, with a multivariable-adjusted relative risk of 0.85 (95% CI: 0.74, 0.99; P = .03).ConclusionReduction in the dose and injection speed of iodinated contrast material for CT was associated with a lower rate of acute hypersensitivity reactions to iodinated contrast material.© RSNA, 2019Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Park HJ, Son JH, Kim TB, et al. Relationship between Lower Dose and Injection Speed of Iodinated Contrast Material for CT and Acute Hypersensitivity Reactions: An Observational Study. Radiology. 2019. PMID: 31617789. doi:10.1148/radiol.2019190829

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。