文献速递腹部介入DSA

透视下挽救性支架置入治疗内镜支架置入失败的梗阻性结直肠恶性肿瘤

Fluoroscopic Rescue of Failed Endoscopic Stent Placement for Obstructing Colorectal Malignancy.
PubMed 文献 · AJR Am J Roentgenol · 2019-10-15

本研究回顾性分析2004年至2017年间41例内镜支架置入失败的恶性结直肠梗阻患者,转而行透视下支架置入。技术成功率为92.7%(38/41),临床成功率为97.4%(37/38),主要并发症发生率为7.9%(3/38)。作者结论认为透视下结直肠支架置入在多数内镜操作失败的患者中技术可行且临床有效。

要点

  • 内镜支架置入失败后,透视下支架置入技术成功率为92.7%(38/41)。
  • 技术成功者中临床成功率为97.4%(37/38)。
  • 主要并发症发生率为7.9%(3/38),包括结肠穿孔2例和肛门疼痛1例。

核心结论

  • 透视下结直肠支架置入在内镜操作失败的多数患者中技术可行且临床有效。

研究设计与样本

  • 回顾性分析,2004年1月至2017年12月间41例恶性结直肠梗阻且内镜支架置入失败后转行透视下支架置入的患者,其中姑息性治疗35例、作为手术桥接6例。

诊断标准与关键数值

  • 技术成功定义为透视下支架置入成功,38/41例(92.7%)技术成功。
  • 临床成功定义为技术成功者中梗阻症状缓解,37/38例(97.4%)临床成功。
  • 技术失败原因包括完全梗阻1例、乙状结肠冗长1例和结肠穿孔1例。
  • 主要并发症包括结肠穿孔2例和肛门疼痛1例,共3/38例(7.9%)。
  • 6例作为手术桥接的患者均顺利接受择期结肠切除术(100%)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. This study evaluated the technical feasibility and clinical effectiveness of fluoroscopic stent placement in malignant colorectal obstructions after failed endoscopic stent placement. MATERIALS AND METHODS. Between January 2004 and December 2017, 41 patients with malignant colorectal obstructions were referred for fluoroscopic stent placement after failed endoscopy. The procedures were performed for palliation (n = 35) or as a bridge to surgery (n = 6). The technical and clinical success, complications, stent patency duration, and patient survival were retrospectively analyzed. RESULTS. Fluoroscopic stent placement was technically successful in 38 patients (92.7%). The causes of technical failure were complete obstruction (n = 1), redundant sigmoid colon (n = 1), and colon perforation (n = 1). Clinical success was achieved in 37 patients with technical success (97.4%). Major complications occurred in three patients (7.9%) and included colon perforation (n = 2) and anal pain (n = 1). The six patients with stenting as a bridge to surgery underwent elective colectomy uneventfully (100%). In 32 patients with technically successful palliative stenting, the median primary stent patency duration and patient survival were 353 days (95% CI, 162-353 days) and 335 days (95% CI, 116-335 days), respectively. CONCLUSION. Fluoroscopic colorectal stent placement is technically feasible and clinically effective in most patients with failed endoscopic procedures.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Kim DR, Yoon CJ, Lee JH, et al. Fluoroscopic Rescue of Failed Endoscopic Stent Placement for Obstructing Colorectal Malignancy. AJR Am J Roentgenol. 2019. PMID: 31613658. doi:10.2214/AJR.19.21744

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。