PET-MR成像与MR纹理分析在胰腺囊性病变诊断中的应用:一项前瞻性初步研究
研究前瞻性纳入40例连续患者,于治疗前行18F-FDG PET-MR检查,从T2FS和ADC图提取30个纹理参数并测量SUVmax和SUVmean,比较良恶性胰腺囊性病变。恶性囊性病变FDG摄取显著更高,SUVmean的AUC为0.892,代谢与纹理特征联合模型AUC提升至0.961。作者认为PET-MR在鉴别良恶性胰腺囊性病变方面较传统PET相关成像无明显优势,但联合诊断模型表现满意。
要点
- 恶性胰腺囊性病变的SUVmax(p=0.002)和SUVmean(p<0.001)均显著高于良性病变。
- T2FS图像空间缩放因子3-6mm的标准差在恶性囊性病变中显著更低(p<0.01)。
- ADC图像空间缩放因子2-4mm的偏度在恶性囊性病变中显著更低(p<0.01)。
核心结论
- 作者认为PET-MR在鉴别良恶性胰腺囊性病变方面较传统PET相关成像无明显优势。
- 基于代谢与纹理参数联合的诊断模型表现出满意的诊断性能,AUC为0.961。
研究设计与样本
- 前瞻性初步研究,连续纳入40例患者。
- 所有患者于治疗前行同步PET-MR检查以诊断胰腺囊肿。
- 从手动勾画的轴位T2加权脂肪抑制(T2FS)图像和表观扩散系数(ADC)图像分别提取30个纹理参数。
- 在PET-MR图像上测量胰腺囊肿的最大和平均标准化摄取值(SUVmax和SUVmean)。
- 采用Mann-Whitney检验比较良恶性组间的纹理参数和代谢参数。
关键影像表现/征象
- 恶性胰腺囊性病变的FDG摄取显著高于良性病变(SUVmax p=0.002,SUVmean p<0.001)。
- 恶性囊肿在T2FS图像上空间缩放因子3-6mm的标准差显著更低(p<0.01)。
- 恶性囊肿在ADC图像上空间缩放因子2-4mm的偏度显著更低(p<0.01)。
诊断标准与关键数值
- SUVmean的AUC为0.892,敏感度88.9%、特异度87.1%、准确率87.6%。
- 代谢与纹理特征联合诊断模型的AUC为0.961,敏感度88.9%、特异度96.8%、准确率95.0%。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Our aim was to evaluate the capability of textural and metabolic parameters measured at pretreatment 18F-fluorodeoxyglucose Positron emission tomography (PET)-MR in differentiating malignant from benign pancreatic cystic lesions.
MATERIALS AND METHOD: Forty consecutive patients were prospectively enrolled in this study. They underwent simultaneous PET-MR for the diagnosis of pancreatic cysts. Thirty texture parameters were extracted from manually contoured axial T2-weighted imaging with fat suppression (T2FS) and apparent diffusion coefficient images, respectively. Maximal and mean standardized uptake values (SUVmax and SUVmean, respectively) of pancreatic cysts were measured at PET-MR imaging. The Mann-Whitney test was used to compare both textural and metabolic parameters between benign and malignant group.
RESULTS: FDG uptake was significantly higher in patients with malignant pancreatic cysts (SUVmaxp = 0.002, SUVmeanp < 0.001). Malignant cysts showed significantly lower standard deviation for spatial scaling factor at 3-6mm on T2FS images and lower skewness for spatial scaling factor at 2-4mm on apparent diffusion coefficient images (p < 0.01). SUVmean had the highest Area under the curve of 0.892 on receiver-operating characteristic analysis with a sensitivity, specificity, and accuracy of 88.9%, 87.1%, and 87.6%, respectively. When metabolic and textural features were combined into a single diagnostic model, the AUC increased to 0.961, with a sensitivity, specificity, and accuracy of 88.9%, 96.8%, and 95.0%, respectively.
CONCLUSION: Our study implied that PET-MR showed no obvious advantages over traditional PET-related imaging in differentiating malignant from benign pancreatic cystic lesions. Diagnostic model based on the combination of metabolic and textural parameters showed satisfactory performance.
引用
- Cheng SH, Liu D, Hou B, et al. PET-MR Imaging and MR Texture Analysis in the Diagnosis of Pancreatic Cysts: A Prospective Preliminary Study. Acad Radiol. 2019. PMID: 31606313. doi:10.1016/j.acra.2019.09.001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。