文献速递腹部CT

新型双层光谱探测器CT单能重建改善胃癌可视化并提高病灶显示与浸润深度诊断效能

Improved Visualization of Gastric Cancer and Increased Diagnostic Performance in Lesion Depiction and Depth Identification Using Monoenergetic Reconstructions from a Novel Dual-Layer Spectral Detector CT.
PubMed 文献 · Acad Radiol · 2019-09-30

研究回顾性纳入82例胃癌患者,在双层光谱探测器CT门静脉期比较40–70 keV虚拟单能图像与120 kVp常规多能图像,40 keV的对比噪声比和主观图像质量最高。手术组41例中,40 keV单能图像对T分期诊断准确率显著高于120 kVp图像(78.11% vs 41.5%),pT1患者准确率提高53.8%(61.5% vs 7.7%)。

要点

  • 40 keV虚拟单能图像胃癌对比噪声比10.4±4.6,显著高于120 kVp多能图像的3.5±1.5(p<0.001)。
  • 40 keV单能图像胃癌T分期准确率78.11%,显著高于120 kVp多能图像的41.5%(p<0.001)。
  • pT1胃癌中40 keV单能图像诊断准确率61.5%,较120 kVp多能图像的7.7%提高53.8%(p=0.016)。

核心结论

  • 40 keV虚拟单能图像在客观和主观图像质量上均表现最佳,可改善胃癌病灶显示并提高T分期准确率。

研究设计与样本

  • 回顾性研究,共纳入82例胃癌患者,其中41例未手术者用于图像质量评估,另41例手术者用于诊断效能比较。
  • 使用新型双层光谱探测器CT门静脉期重建40–70 keV(间隔10 keV)虚拟单能图像与120 kVp常规多能图像。
  • 客观图像质量以胃癌对比噪声比评估,主观图像质量采用5点Likert量表比较。

关键影像表现/征象

  • 40 keV虚拟单能图像胃癌对比噪声比10.4±4.6,为所有虚拟单能图像中最高。
  • 40 keV虚拟单能图像胃癌主观图像质量评分4.92±0.26,高于120 kVp多能图像的4.15±0.82(p<0.001)。

诊断标准与关键数值

  • 40 keV虚拟单能图像胃癌检出率92.7%,120 kVp多能图像为82.9%(p=0.125)。
  • 40 keV虚拟单能图像T分期诊断准确率78.11%,120 kVp多能图像为41.5%(p<0.001)。
  • pT1胃癌中40 keV虚拟单能图像诊断准确率61.5%,120 kVp多能图像为7.7%(p=0.016)。

临床应用与阅片要点

  • 在双层光谱探测器CT门静脉期重建40 keV虚拟单能图像,可提高胃癌病灶对比噪声比和主观图像质量。
  • 40 keV虚拟单能图像有助于提高胃癌T分期诊断准确率,尤其在pT1患者中诊断准确率提升更明显。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To determine the optimal keV for the visualization of gastric cancer and to investigate its value in depicting lesions and in identifying depth invasion using virtual monoenergetic images (VMIs) on a novel dual-layer spectral detector CT.

MATERIALS AND METHODS: Eighty-two gastric cancer patients were retrospectively enrolled, and 41 patients who did not undergo surgery were evaluated for image quality in VMIs at different keVs (40 keV-70 keV with 10 keV increments) and in conventional 120 kVp polyenergetic images (PEIs) reconstructed from the portal venous phase. Objective image quality was assessed by the contrast-to-noise ratio of the gastric cancer, while subjective performance was compared using a 5-point Likert scale. Another 41 patients who underwent surgery were examined to compare the diagnostic performance of the VMIs taken at the optimal keV and that of the 120 kVp-PEIs.

RESULTS: The contrast-to-noise ratio of gastric cancer at 40 keV (10.4 ± 4.6) was the highest among all the VMIs and was significantly superior to that of the 120 kVp-PEIs (3.5 ± 1.5, p < 0.001). Gastric-specific image quality was rated highest for the 40 keV-VMIs (4.92 ± 0.26), which was significantly superior to that of the 120 kVp-PEIs (4.15 ± 0.82, p < 0.001). In the diagnostic group, there were 13 pT1, 10 pT2, 9 pT3, and 9 pT4 gastric cancer patients. Compared with the 120 kVp-PEIs, the VMIs at 40 keV tended to have a higher detection rate of gastric cancer (82.9% vs. 92.7%, respectively, p = 0.125) and a significantly improved diagnostic accuracy in the T stage (from 41.5% to 78.11%, respectively) (p < 0.001), particularly in pT1 patients, whose diagnostic accuracy was improved by 53.8% (7.7% vs. 61.5%, respectively, p = 0.016).

CONCLUSION: VMIs at 40 keV performed the best, both objectively and subjectively, for gastric cancer, leading to improved lesion depiction and higher T stage accuracy.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Liu JJ, Liu W, Jin ZY, et al. Improved Visualization of Gastric Cancer and Increased Diagnostic Performance in Lesion Depiction and Depth Identification Using Monoenergetic Reconstructions from a Novel Dual-Layer Spectral Detector CT. Acad Radiol. 2019. PMID: 31582193. doi:10.1016/j.acra.2019.09.004