新型双层光谱探测器CT单能重建改善胃癌可视化并提高病灶显示与浸润深度诊断效能
研究回顾性纳入82例胃癌患者,在双层光谱探测器CT门静脉期比较40–70 keV虚拟单能图像与120 kVp常规多能图像,40 keV的对比噪声比和主观图像质量最高。手术组41例中,40 keV单能图像对T分期诊断准确率显著高于120 kVp图像(78.11% vs 41.5%),pT1患者准确率提高53.8%(61.5% vs 7.7%)。
要点
- 40 keV虚拟单能图像胃癌对比噪声比10.4±4.6,显著高于120 kVp多能图像的3.5±1.5(p<0.001)。
- 40 keV单能图像胃癌T分期准确率78.11%,显著高于120 kVp多能图像的41.5%(p<0.001)。
- pT1胃癌中40 keV单能图像诊断准确率61.5%,较120 kVp多能图像的7.7%提高53.8%(p=0.016)。
核心结论
- 40 keV虚拟单能图像在客观和主观图像质量上均表现最佳,可改善胃癌病灶显示并提高T分期准确率。
研究设计与样本
- 回顾性研究,共纳入82例胃癌患者,其中41例未手术者用于图像质量评估,另41例手术者用于诊断效能比较。
- 使用新型双层光谱探测器CT门静脉期重建40–70 keV(间隔10 keV)虚拟单能图像与120 kVp常规多能图像。
- 客观图像质量以胃癌对比噪声比评估,主观图像质量采用5点Likert量表比较。
关键影像表现/征象
- 40 keV虚拟单能图像胃癌对比噪声比10.4±4.6,为所有虚拟单能图像中最高。
- 40 keV虚拟单能图像胃癌主观图像质量评分4.92±0.26,高于120 kVp多能图像的4.15±0.82(p<0.001)。
诊断标准与关键数值
- 40 keV虚拟单能图像胃癌检出率92.7%,120 kVp多能图像为82.9%(p=0.125)。
- 40 keV虚拟单能图像T分期诊断准确率78.11%,120 kVp多能图像为41.5%(p<0.001)。
- pT1胃癌中40 keV虚拟单能图像诊断准确率61.5%,120 kVp多能图像为7.7%(p=0.016)。
临床应用与阅片要点
- 在双层光谱探测器CT门静脉期重建40 keV虚拟单能图像,可提高胃癌病灶对比噪声比和主观图像质量。
- 40 keV虚拟单能图像有助于提高胃癌T分期诊断准确率,尤其在pT1患者中诊断准确率提升更明显。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To determine the optimal keV for the visualization of gastric cancer and to investigate its value in depicting lesions and in identifying depth invasion using virtual monoenergetic images (VMIs) on a novel dual-layer spectral detector CT.
MATERIALS AND METHODS: Eighty-two gastric cancer patients were retrospectively enrolled, and 41 patients who did not undergo surgery were evaluated for image quality in VMIs at different keVs (40 keV-70 keV with 10 keV increments) and in conventional 120 kVp polyenergetic images (PEIs) reconstructed from the portal venous phase. Objective image quality was assessed by the contrast-to-noise ratio of the gastric cancer, while subjective performance was compared using a 5-point Likert scale. Another 41 patients who underwent surgery were examined to compare the diagnostic performance of the VMIs taken at the optimal keV and that of the 120 kVp-PEIs.
RESULTS: The contrast-to-noise ratio of gastric cancer at 40 keV (10.4 ± 4.6) was the highest among all the VMIs and was significantly superior to that of the 120 kVp-PEIs (3.5 ± 1.5, p < 0.001). Gastric-specific image quality was rated highest for the 40 keV-VMIs (4.92 ± 0.26), which was significantly superior to that of the 120 kVp-PEIs (4.15 ± 0.82, p < 0.001). In the diagnostic group, there were 13 pT1, 10 pT2, 9 pT3, and 9 pT4 gastric cancer patients. Compared with the 120 kVp-PEIs, the VMIs at 40 keV tended to have a higher detection rate of gastric cancer (82.9% vs. 92.7%, respectively, p = 0.125) and a significantly improved diagnostic accuracy in the T stage (from 41.5% to 78.11%, respectively) (p < 0.001), particularly in pT1 patients, whose diagnostic accuracy was improved by 53.8% (7.7% vs. 61.5%, respectively, p = 0.016).
CONCLUSION: VMIs at 40 keV performed the best, both objectively and subjectively, for gastric cancer, leading to improved lesion depiction and higher T stage accuracy.
引用
- Liu JJ, Liu W, Jin ZY, et al. Improved Visualization of Gastric Cancer and Increased Diagnostic Performance in Lesion Depiction and Depth Identification Using Monoenergetic Reconstructions from a Novel Dual-Layer Spectral Detector CT. Acad Radiol. 2019. PMID: 31582193. doi:10.1016/j.acra.2019.09.004