文献速递腹部MR

基于摄像头的呼吸触发可改善三维磁共振胰胆管成像的图像质量

Camera-based respiratory triggering improves the image quality of 3D magnetic resonance cholangiopancreatography.
PubMed 文献 · Eur J Radiol · 2019-09-23

在28例患者中于同一成像时段内先后采集传统呼吸绑带触发(BRT)与摄像头呼吸触发(CRT)三维MRCP,由2名放射科医师回顾性4分法评分并做ROI与线剖面定量分析。CRT在图像质量、背景抑制、模糊及胰胆管树结构辨识度上评分均显著优于BRT,对比度与管壁线剖面斜率亦显著更高,摄像头呼吸信号曲线信噪比更高、触发错误更少。

要点

  • 摄像头呼吸触发(CRT)三维MRCP的图像质量、背景抑制、模糊及胰胆管树结构辨识度评分显著优于呼吸绑带触发(BRT)。
  • CRT的胆总管与邻近组织对比度为0.94±0.03,高于BRT的0.93±0.03(配对t检验P=0.0017)。
  • CRT的胆总管管壁线剖面斜率为42.23±8.74%最大强度/mm,高于BRT的36.06±8.96%最大强度/mm(配对t检验P<0.0001)。

核心结论

  • 与常规呼吸绑带触发相比,基于摄像头的呼吸触发可显著改善3T三维MRCP的图像质量。

研究设计与样本

  • 在28例患者中于同一成像时段内先后采集传统呼吸绑带触发(BRT)与摄像头呼吸触发(CRT)两套三维MRCP数据,由2名放射科医师回顾性以4分法评分,并采用ROI分析与线剖面定量评价。

关键影像表现/征象

  • CRT在图像质量、背景抑制、模糊及胰胆管树结构辨识度方面的评分显著优于BRT。
  • CRT的胆总管与邻近组织对比度为0.94±0.03,BRT为0.93±0.03,配对t检验P=0.0017。
  • CRT的胆总管管壁线剖面斜率为42.23±8.74%最大强度/mm,BRT为36.06±8.96%最大强度/mm,配对t检验P<0.0001。

诊断标准与关键数值

  • 图像质量、模糊、运动伪影及胰胆管树结构辨识度采用4分法评分。
  • 对比度经感兴趣区(ROI)分析测量胆总管与邻近组织间的对比比值。
  • 模糊与运动伪影通过线剖面量化胆总管管壁处的信号强度增高。

临床应用与阅片要点

  • 两种触发的总扫描时间均为72秒。
  • 摄像头导出的呼吸信号曲线较呼吸绑带导出的曲线信噪比更高、信号幅度标准差更低、错误触发更少。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the performance of a novel camera-based breathing navigation system in respiratory-triggered (CRT) 3D-magnetic resonance cholangiopancreatography (MRCP) at 3T MRI.

METHODS: Two 3D-MRCP data sets were acquired subsequently within one imaging session with traditional respiratory belt- (BRT) or camera- (CRT) based triggering in 28 patients. Overall image quality, blurring, motion artifacts and discernibility of the pancreaticobiliary tree (PBT) structures were scored on a 4-point scale retrospectively by 2 radiologists. The contrast ratio between the common bile duct and its adjacent tissue was measured by region-of-interest (ROI) analysis. The signal intensity increase at the duct boundaries was quantified by line profiles to objectify blurring and motion artifacts. The extracted respiratory signal curves were analyzed for signal quality and trigger timing.

RESULTS: Total scan time was 72 s for both acquisitions. CRT yielded significantly better ratings in image quality, background suppression, blurring and discernibility of PBT structures compared to BRT. Contrast ratios were significantly higher in CRT (0.94 ± 0.03) than in BRT (0.93 ± 0.03) exams; paired t test P = 0.0017. Line profile slopes through the common bile duct revealed significantly higher values in CRT (42.23 ± 8.74% of maximum intensity/mm) compared to BRT (36.06 ± 8.96% of maximum intensity/mm; paired t test P < 0.0001). Camera-derived respiratory signal curves showed a higher SNR, lower standard deviation of the signal amplitude and less incorrect triggering than the respiratory belt-derived respiratory signal curves.

CONCLUSION: Camera-based respiratory triggering significantly improves image quality of 3D-MRCP compared to conventional respiratory belt triggering.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Harder F, Lohöfer FK, Kaissis GA, et al. Camera-based respiratory triggering improves the image quality of 3D magnetic resonance cholangiopancreatography. Eur J Radiol. 2019. PMID: 31585303. doi:10.1016/j.ejrad.2019.108675

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。