文献速递腹部技术与安全USMR

一种新的多模型机器学习框架利用不同厂商的超声弹性成像系统提高肝纤维化分级

A New Multimodel Machine Learning Framework to Improve Hepatic Fibrosis Grading Using Ultrasound Elastography Systems from Different Vendors.
PubMed 文献 · Ultrasound Med Biol · 2019-10-11

研究纳入144例接受pSWE(Siemens)与MRE的患者和60例接受2-DSWE(Philips)与MRE的患者,用10次SWV测量训练四种机器学习算法并以MRE为标准,发现SVM对显著纤维化(≥F2)的二分分级AUC在pSWE为0.96、2-DSWE为0.99,优于中位SWV(0.76、0.84)。

要点

  • 基于10次SWV测量的SVM多厂商模型对肝纤维化二分分级(<F2 vs ≥F2)AUC达pSWE 0.96、2-DSWE 0.99。
  • 中位SWV单独用于二分分级的AUC为pSWE 0.76、2-DSWE 0.84,诊断性能中等。
  • 机器学习算法以MRE为参考标准训练,采用二折交叉验证评估。

核心结论

  • 多厂商机器学习算法SVM可利用超声弹性成像以优异的诊断性能对肝纤维化进行二分分级,与MRE相当。

研究设计与样本

  • 研究纳入两组肝病患者:144例接受pSWE(Siemens)和MRE,60例接受2-DSWE(Philips)和MRE;以10次SWV测量为输入训练四种机器学习算法,以MRE为参考标准,采用二折交叉验证验证结果。

诊断标准与关键数值

  • 以MRE为参考区分非显著纤维化(<F2)与显著纤维化(≥F2);中位SWV的AUC为pSWE 0.76、2-DSWE 0.84;SVM的AUC为pSWE 0.96、2-DSWE 0.99。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

The purpose of the work described here was to determine if the diagnostic performance of point and 2-D shear wave elastography (pSWE; 2-DSWE) using shear wave velocity (SWV) with a new machine learning (ML) technique applied to systems from different vendors is comparable to that of magnetic resonance elastography (MRE) in distinguishing non-significant (<F2) from significant (≥F2) fibrosis. We included two patient groups with liver disease: (i) 144 patients undergoing pSWE (Siemens) and MRE; and (ii) 60 patients undergoing 2-DSWE (Philips) and MRE. Four ML algorithms using 10 SWV measurements as inputs were trained with MRE. Results were validated using twofold cross-validation. The performance of median SWV in binary grading of fibrosis was moderate for pSWE (area under the curve [AUC]: 0.76) and 2-DSWE (0.84); the ML algorithm support vector machine (SVM) performed particularly well (pSWE: 0.96, 2-DSWE: 0.99). The results suggest that the multivendor ML-based algorithm SVM can binarily grade liver fibrosis using ultrasound elastography with excellent diagnostic performance, comparable to that of MRE.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Durot I, Akhbardeh A, Sagreiya H, et al. A New Multimodel Machine Learning Framework to Improve Hepatic Fibrosis Grading Using Ultrasound Elastography Systems from Different Vendors. Ultrasound Med Biol. 2019. PMID: 31611074. doi:10.1016/j.ultrasmedbio.2019.09.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。