文献速递心血管外周血管MRCT

4D flow MRI检测B型主动脉夹层内膜片破口及其血流动力学评估:与传统MRI和CTA的比较

Detection and Hemodynamic Evaluation of Flap Fenestrations in Type B Aortic Dissection with 4D Flow MRI: Comparison with Conventional MRI and CTA.
PubMed 文献 · Radiol Cardiothorac Imaging · 2019-04-25

回顾性纳入19例B型主动脉夹层患者,比较4D flow MRI、临床MRI/MRA与临床CTA对内膜片破口的检出及血流方向评估。4D flow检出破口数相对MRI/MRA略多,相对CTA相近,MRI/MRA相对CTA略少,差异均无统计学意义。多数破口呈双相血流(收缩期流入假腔、舒张期流出)。

要点

  • 4D flow MRI可检出B型主动脉夹层的小内膜片破口,并提供整个心动周期的血流方向信息。
  • 4D flow与CTA检出破口数相近,MRI/MRA检出相对CTA略少,差异均无统计学意义。
  • 多数破口表现为双相血流:收缩期流入假腔、舒张期流出。

核心结论

  • 4D flow MRI能检出B型主动脉夹层患者的小内膜片破口,并相对CTA和传统MRI提供破口处整个心动周期的额外血流信息。

研究设计与样本

  • 回顾性识别19例B型主动脉夹层患者(年龄57±5岁),均接受包含4D flow MRI的胸部标准诊疗MRI/MRA。
  • 19例中14例在MRI/MRA研究前2年内接受CTA且期间无手术。
  • 由两名放射科医师独立阅片,记录破口(含入口和出口撕裂)数目、位置及血流方向。
  • 采用Wilcoxon符号秩检验比较各技术间检出率的差异。

关键影像表现/征象

  • 多数破口在整个心动周期呈双相血流,即收缩期血流流入假腔、舒张期流出(阅片者1:18/33,阅片者2:16/30)。

诊断标准与关键数值

  • 4D flow相对MRI/MRA检出破口数:阅片者1增加3个(10%),阅片者2增加5个(20%)。
  • 4D flow相对CTA检出破口数:阅片者1增加1个(4%),阅片者2减少3个(-12%)。
  • MRI/MRA相对CTA检出破口数:阅片者1减少6个(-24%),阅片者2减少5个(-19%)。
  • 上述技术间检出率差异均无统计学意义。
  • 联合4D flow与MRI/MRA可检出更多破口。

临床应用与阅片要点

  • 阅片时可关注4D flow显示的破口处血流方向,以补充CTA和传统MRI对破口血流的评估。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The purpose of this study was to compare dissection flap fenestration visualization between 4D flow MRI, clinical MRI/MRA, and clinical CTA studies and describe the presence of hemodynamically active fenestration flow using 4D flow.

MATERIALS AND METHODS: Nineteen patients with type B dissection (age: 57±5 years) who had undergone standard of-care MRI/MRA of the chest including 4D flow MRI were retrospectively identified. Fourteen of the 19 patients also had CTA performed within 2 years of the MRI/MRA study with no interval surgery. Image review was performed independently by two radiologists. The number of fenestrations (including entry and exit tears), location, and flow directionality were recorded. Differences in the rate of detection between techniques was assessed using a Wilcoxon signed rank test.

RESULTS: 4D flow detected more fenestrations relative to MRI/MRA [rev 1: +3 (10%), rev 2: +5 (20%)]. There were similar numbers of fenestrations detected by 4D flow relative to CTA [rev 1: +1 (4%), rev 2: -3 (-12%)]. MRI/MRA detected fewer fenestration relative to CTA in this cohort [rev 1: -6 (-24%), rev 2: -5 (-19%)]. No differences were significant. Combining 4D flow and MRI/MRA resulted in additional fenestration detection. Most fenestrations demonstrated biphasic flow over the cardiac cycle (flow entering false lumen in systole and exiting during diastole, rev 1:18/33, rev 2: 16/30).

CONCLUSIONS: 4D flow MRI can detect small flap fenestration in type B dissection patients while providing additional information about flow through fenestrations throughout the cardiac cycle relative to CTA and conventional MRI.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Allen BD, Aouad PJ, Burris NS, et al. Detection and Hemodynamic Evaluation of Flap Fenestrations in Type B Aortic Dissection with 4D Flow MRI: Comparison with Conventional MRI and CTA. Radiol Cardiothorac Imaging. 2019. PMID: 31598608. doi:10.1148/ryct.2019180009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。