低管电压冠状动脉CT血管成像的假阴性:冠状动脉CT血管成像中高血管内衰减可掩盖钙化斑块

False-Negative Low Tube Voltage Coronary CT Angiography: High Intravascular Attenuation at Coronary CT Angiography Can Mask Calcified Plaques.
PubMed 文献 · Radiol Cardiothorac Imaging · 2019-10-31

该回顾性研究从急诊科冠状动脉CT血管成像登记处抽样264例患者,以冠状动脉CT血管成像联合冠状动脉钙化扫描为参考标准,评估单独冠状动脉CT血管成像对斑块的检出效能。结果显示低管电压组漏诊斑块比例显著高于标准管电压组,且低管电压组更常见钙化斑块呈等密度于管腔内对比剂衰减而漏诊。

要点

  • 单独冠状动脉CT血管成像阅片时,低管电压组漏诊斑块比例显著高于标准管电压组。
  • 低管电压组因漏诊斑块导致CAD-RADS分类错误的比例显著高于标准管电压组。
  • 低管电压组中钙化斑块呈等密度于管腔内对比剂衰减的比例显著高于标准管电压组。

核心结论

  • 低管电压冠状动脉CT血管成像检查若不联合冠状动脉钙化扫描,可能漏诊冠状动脉斑块。

研究设计与样本

  • 回顾性抽样急诊科冠状动脉CT血管成像登记处数据,样本量264例,所有患者先以120 kV行非对比冠状动脉钙化评分扫描再行冠状动脉CT血管成像。

关键影像表现/征象

  • 低管电压组钙化斑块呈等密度于管腔内对比剂衰减的比例为20%(32/159),标准管电压组为7.6%(8/105),P = .005。
  • 单独冠状动脉CT血管成像阅片时,低管电压组漏诊斑块比例为41%(85/206),标准管电压组为5%(12/249),P < .001。
  • 漏诊斑块导致CAD-RADS分类错误在低管电压组为8.8%(14/159),标准管电压组为2%(2/105),P = .01。
  • CAD-RADS分类错误通常见于低斑块负荷,中位冠状动脉钙化评分为1,范围1-4。

诊断标准与关键数值

  • 以冠状动脉CT血管成像联合冠状动脉钙化扫描为参考标准评估单独冠状动脉CT血管成像的斑块检出和CAD-RADS分类效能。
  • 共识别455个斑块,分布于118例患者(低管电压组70/159,标准管电压组48/105)。
  • 单独冠状动脉CT血管成像阅片漏诊97/455(21%)个斑块,导致16/264(6%)例CAD-RADS分类错误(误判为CAD-RADS 0而非CAD-RADS 1或2)。

临床应用与阅片要点

  • 低管电压冠状动脉CT血管成像阅片时需注意钙化斑块可能呈等密度于管腔内对比剂衰减而漏诊。
  • 对于低斑块负荷患者,单独冠状动脉CT血管成像可能将CAD-RADS 1或2误判为CAD-RADS 0。
  • 结合冠状动脉钙化扫描可提高低管电压冠状动脉CT血管成像对斑块的检出和CAD-RADS分类准确性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To determine the impact of low tube voltage coronary CT angiography on detection of subclinical atherosclerosis.

MATERIALS AND METHODS: Retrospective sampling of an emergency department coronary CT angiography registry was performed. All patients in the registry underwent a noncontrast coronary artery calcium (CAC) scoring scan at 120 kV before coronary CT angiography. The study sample (n = 264) constituted patients with subclinical atherosclerosis (Coronary Artery Disease Reporting and Data System™ [CAD-RADS] 1 or 2) randomly mixed one-to-one with patients without atherosclerosis (CAD-RADS 0). The patients with coronary CT angiography performed at 70-90 kV were considered the low tube voltage group (n = 159) and patients with coronary CT angiography performed at 100-120 kV were considered the standard tube voltage group (n = 105). The number of coronary plaques and overall CAD-RADS classification (per patient) were evaluated twice: initially, by reading coronary CT angiography alone, and then, by coronary CT angiography in combination with a CAC scan. Considering the combined reading (CT angiography plus CAC scan) as the reference standard, the performance of coronary CT angiography alone was assessed for plaque detection and appropriate CAD-RADS (per patient) classification. The comparisons were made between the low tube voltage and standard tube voltage groups by using a Fisher exact test and χ2 test for proportions and a Mann-Whitney test and Kruskal-Wallis test for means.

RESULTS: In total, 455 plaques were identified in 118 patients (70 of 159 patients in the low tube voltage group; 48 of 105 in the standard tube voltage group). When reading coronary CT angiographic images alone, 97 of 455 (21%) plaques were missed that led to an incorrect CAD-RADS classification in 16 of 264 (6%) studies (interpreted as CAD-RADS 0 instead of CAD-RADS 1 or 2). Missed plaques were significantly more frequent in the low tube voltage group versus the standard tube voltage group (41% [85 of 206] vs 5% [12 of 249], respectively; P < .001). Incorrect CAD-RADS classification was also seen more commonly in the low tube voltage group (8.8% [14 of 159] vs 2% [two of 105]; P = .01), typically at low plaque burden (median CAC score, 1; range, 1-4). Calcified plaques that appeared isodense to luminal contrast material attenuation were seen more frequently in the low tube voltage group compared with the standard tube voltage group (20% [32 of 159] vs 7.6% [eight of 105], respectively; P = .005).

CONCLUSION: Coronary artery plaques may be missed at low tube voltage coronary CT angiographic examination performed without a concomitant CAC scan.© RSNA, 2019Supplemental material is available for this article.See also the commentary by Truong in this issue.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Baliyan V, Scholtz JE, Kordbacheh H, et al. False-Negative Low Tube Voltage Coronary CT Angiography: High Intravascular Attenuation at Coronary CT Angiography Can Mask Calcified Plaques. Radiol Cardiothorac Imaging. 2019. PMID: 33778520. doi:10.1148/ryct.2019190039

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。