颈动脉校正血流时间与峰值血流速度呼吸变异预测成人择期手术全麻诱导后低血压:一项前瞻性观察性研究
该前瞻性观察性研究纳入112例择期全麻手术成人患者,于诱导前10分钟用超声测量颈总动脉校正血流时间(cFT)和颈动脉峰值血流速度变异(ðVpeak),评估其预测全麻诱导后低血压的效用。cFT预测诱导后低血压的AUC为0.91,最佳截断值≤330.2毫秒,敏感度85.7%、特异度96.8%;ðVpeak预测能力较差,AUC为0.68,最佳截断值18.8%,敏感度61.9%、特异度67.4%。
要点
- 颈总动脉cFT≤330.2毫秒预测全麻诱导后低血压的AUC为0.91,敏感度85.7%、特异度96.8%。
- ðVpeak预测诱导后低血压的AUC为0.68,最佳截断值18.8%,敏感度61.9%、特异度67.4%。
- cFT与诱导后2分钟和3分钟收缩压下降百分比及1、2、3分钟平均动脉压下降百分比显著相关。
核心结论
- 颈总动脉cFT是全麻诱导后低血压的合理预测指标,ðVpeak预测能力较差;需进一步研究确定其在高危患者中的作用及测量者间和测量者内变异性。
研究设计与样本
- 前瞻性观察性研究,纳入112例择期全麻手术成人患者,禁食至少6至8小时,于全麻诱导前10分钟用超声测量颈总动脉cFT和ðVpeak,随后用丙泊酚行全麻,收集血流动力学数据至诱导后3分钟。
关键影像表现/征象
- cFT与诱导后2分钟(P<.0001)和3分钟(P<.0001)收缩压下降百分比显著相关。
- cFT与诱导后1分钟(P=.0006)、2分钟(P<.0001)和3分钟(P<.0001)平均动脉压下降百分比显著相关。
诊断标准与关键数值
- cFT预测全麻诱导后低血压的AUC为0.91,最佳截断值≤330.2毫秒,敏感度85.7%、特异度96.8%。
- ðVpeak预测全麻诱导后低血压的AUC为0.68,最佳截断值18.8%,敏感度61.9%、特异度67.4%。
临床应用与阅片要点
- 择期全麻手术成人患者诱导前10分钟可测量颈总动脉cFT,cFT≤330.2毫秒提示诱导后低血压风险较高。
局限性
- 需进一步研究确定cFT在高危患者(如老年人群和心血管疾病患者)中的作用。
- 需进一步研究确定cFT和ðVpeak测量的测量者间和测量者内变异性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Hypotension is common after induction of general anesthesia, and intraoperative hypotension is associated with postoperative end-organ injury such as acute kidney injury and myocardial ischemia. This study was designed to determine the utility of the carotid corrected flow time (cFT) and carotid artery peak blood flow velocity variation (ðVpeak ) for prediction of hypotension after induction of general anesthesia.
METHODS: Adult patients (n = 112) undergoing any elective surgery under general anesthesia who fasted for at least 6 to 8 hours were recruited in this prospective observational study. The common carotid artery cFT and ðVpeak were measured with ultrasound 10 minutes before induction of general anesthesia. After that, general anesthesia with propofol was used, and hemodynamic data were collected until 3 minutes after induction of anesthesia.
RESULTS: The carotid cFT was significantly correlated with percentages of the fall in the systolic blood pressure at 2 minutes (P < .0001) and 3 minutes (P < .0001) and percentages of the fall in the mean arterial pressure at 1 minute (P = .0006), 2 minutes (P < .0001), and 3 minutes (P < .0001). The cFT was a predictor of hypotension after induction of general anesthesia, with an area under the receiver operating characteristic curve of 0.91. The best cutoff value obtained from this study was 330.2 milliseconds or less, which predicted postinduction hypotension with sensitivity and specificity of 85.7% and 96.8%, respectively. The ðVpeak was an inferior predictor of postinduction hypotension, with an area under the receiver operating characteristic curve of 0.68. The optimum cutoff value was 18.8%, with sensitivity and specificity of 61.9% and 67.4%.
CONCLUSIONS: The cFT measured in the common carotid artery is a reasonable predictor of hypotension after induction of general anesthesia in American Society of Anesthesiologists physical status I and II patients. Further studies are required to identify its role in high-risk patients such as older groups and patients with cardiovascular diseases and also to identify interobserver and intraobserver variability of cFT and ðVpeak measurements.
引用
- Maitra S, Baidya DK, Anand RK, et al. Carotid Artery Corrected Flow Time and Respiratory Variations of Peak Blood Flow Velocity for Prediction of Hypotension After Induction of General Anesthesia in Adult Patients Undergoing Elective Surgery: A Prospective Observational Study. J Ultrasound Med. 2019. PMID: 31647132. doi:10.1002/jum.15151