基于患者特异性集总参数模型的现场冠状动脉CT血管成像衍生血流储备分数的诊断效能
本回顾性可行性研究纳入57例患者共77支血管,评估基于患者特异性集总参数模型的原型现场CT血流储备分数(CT FFR)算法对侵入性FFR定义的功能性显著狭窄的检出效能,并与冠状动脉CT血管成像(CCTA)解剖学狭窄程度评估比较。CT FFR的AUC为0.87,优于狭窄程度评估的AUC 0.70(ΔAUC 0.17,P<.01),诊断效能更优。
要点
- CT FFR以≤0.80为阈值诊断功能性显著狭窄的AUC为0.87,优于CCTA狭窄程度评估的AUC 0.70。
- CT FFR的敏感度为89.2%(33/37),特异度为77.5%(31/40),准确度为83.1%(64/77)。
- CCTA狭窄程度≥50%的敏感度为89.2%(33/37),特异度为42.5%(17/40),准确度为64.9%(50/77)。
核心结论
- 在疑似或已知冠状动脉疾病患者中,现场CT FFR对功能性显著冠状动脉狭窄的诊断效能优于CCTA狭窄程度评估。
研究设计与样本
- 回顾性可行性研究,纳入57例患者共77支血管,其中42例(74%)为男性,平均年龄58.5岁±9.2(标准差)。
- 患者均在侵入性FFR测量前60天内接受临床指征的CCTA检查,以侵入性FFR≤0.80定义功能性显著狭窄,按血管水平分析。
诊断标准与关键数值
- CT FFR以≤0.80为阈值:敏感度89.2%(33/37),特异度77.5%(31/40),阳性预测值78.6%(33/42),阴性预测值88.6%(31/35),准确度83.1%(64/77)。
- CCTA狭窄程度以≥50%为阈值:敏感度89.2%(33/37),特异度42.5%(17/40),阳性预测值58.9%(33/56),阴性预测值81.0%(17/21),准确度64.9%(50/77)。
- CT FFR诊断功能性显著狭窄的AUC为0.87,CCTA狭窄程度评估的AUC为0.70,ΔAUC 0.17,P<.01。
临床应用与阅片要点
- 现场CT FFR可基于患者特异性集总参数模型在CCTA基础上无创评估功能性显著狭窄,其诊断效能优于单纯狭窄程度评估。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the diagnostic performance of a prototype on-site coronary CT angiography-derived fractional flow reserve (CT FFR) algorithm, based on patient-specific lumped parameter models, for the detection of functionally significant stenosis defined by invasive FFR, and to compare the performance to anatomic evaluation of stenosis degree.
MATERIALS AND METHODS: In this retrospective feasibility study, 77 vessels in 57 patients (42 of 57 [74%]) men; mean age, 58.5 years ± 9.2 [standard deviation]) who underwent clinically indicated coronary CT angiography within 60 days prior to an invasive FFR measurement were analyzed. Invasive FFR less than or equal to 0.80 was used to indicate a functionally significant stenosis. Diagnostic performance of CT FFR was evaluated and compared with evaluation of stenosis degree. Analysis was performed on a per-vessel basis.
RESULTS: Invasive FFR revealed functionally significant stenoses in 37 vessels (48%). CT FFR showed a significantly increased ability to indicate functionally significant stenosis (area under the receiver operating characteristic curve [AUC], 0.87) compared with degree of stenosis at coronary CT angiography (AUC, 0.70; ΔAUC 0.17; P < .01). Using a cutoff of less than or equal to 0.80 for CT FFR and greater than or equal to 50% degree of stenosis at coronary CT angiography to indicate a significant stenosis, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 33 of 37 (89.2%), 31 of 40 (77.5%), 33 of 42 (78.6%), 31 of 35 (88.6%), and 64 of 77 (83.1%), respectively, for CT FFR, and 33 of 37 (89.2%), 17 of 40 (42.5%), 33 of 56 (58.9%), 17 of 21 (81.0%), and 50 of 77 (64.9%), respectively, for degree of stenosis at coronary CT angiography.
CONCLUSION: Diagnostic performance of on-site CT FFR was superior to stenosis evaluation at coronary CT angiography for identification of functionally significant coronary artery stenosis in patients suspected of having or known to have coronary artery disease.© RSNA, 2019See also commentary by Schoepf et al.
引用
- van Hamersvelt RW, Voskuil M, de Jong PA, et al. Diagnostic Performance of On-Site Coronary CT Angiography-derived Fractional Flow Reserve Based on Patient-specific Lumped Parameter Models. Radiol Cardiothorac Imaging. 2019. PMID: 33778519. doi:10.1148/ryct.2019190036
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。