基于卷积神经网络模型比较CT与MRI图像预测软组织肉瘤分级和肺转移
回顾性分析51例软组织肉瘤患者的CT、T1W和抑脂T2W MRI图像,按5:2:3分为训练、验证和测试组,用CNN模型预测肿瘤分级和肺转移。测试集上FST2W预测分级和肺转移的准确率分别为0.89和0.93,AUC分别为0.97和0.96,表现最佳。作者认为MRI和CT结合CNN模型有助于预测软组织肉瘤分级和肺转移。
要点
- FST2W预测软组织肉瘤分级的准确率0.89、AUC 0.97,优于T1W、CT及两者融合。
- FST2W预测肺转移的准确率0.93、AUC 0.96,优于T1W、CT及两者融合。
- T1W与FST2W融合预测分级准确率0.85、AUC 0.94,低于单用FST2W。
核心结论
- MRI和CT图像结合CNN模型可用于预测软组织肉瘤分级和肺转移,从而为患者诊断和治疗提供帮助。
- FST2W MRI在预测软组织肉瘤分级和肺转移方面表现最佳。
研究设计与样本
- 回顾性分析51例诊断为软组织肉瘤患者的MRI和CT图像。
- 按疾病分级分为高级别组28例、中级别组15例、低级别组8例;32例有肺转移,19例无肺转移。
- 数据按5:2:3比例分为训练组、验证组和测试组。
- 基于CT、T1W MRI和抑脂T2W MRI图像构建卷积神经网络模型,用测试集ROC曲线和准确率评估模型性能。
诊断标准与关键数值
- 软组织肉瘤分级预测:测试集准确率T1W 0.86、FST2W 0.89、CT 0.86、T1W与FST2W融合0.85;AUC分别为0.96、0.97、0.97、0.94。
- 肺转移预测:测试集准确率T1W 0.92、FST2W 0.93、CT 0.88、T1W与FST2W融合0.91;AUC分别为0.97、0.96、0.95、0.95。
临床应用与阅片要点
- 作者认为MRI和CT图像结合CNN模型可用于预测软组织肉瘤分级和肺转移,为患者诊断和治疗提供帮助。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To realise the automated prediction of soft-tissue sarcoma (STS) grading and lung metastasis based on computed tomography (CT), T1-weighted (T1W) magnetic resonance imaging (MRI), and fat-suppressed T2-weighted MRI (FST2W) via the convolutional neural networks (CNN) model.
MATERIALS AND METHODS: MRI and CT images of 51 patients diagnosed with STS were analysed retrospectively. The patients could be divided into three groups based on disease grading: high-grade group (n=28), intermediate-grade group (n=15), low-grade group (n=8). Among these patients, 32 had lung metastasis, while the remaining 19 had no lung metastasis. The data were divided into the training, validation, and testing groups according to the ratio of 5:2:3. The receiver operating characteristic (ROC) curves and accuracy values were acquired using the testing dataset to evaluate the performance of the CNN model.
RESULTS: For STS grading, the accuracy of the T1W, FST2W, CT, and the fusion of T1W and FST2W testing data were 0.86, 0.89, 0.86, and 0.85, respectively. In addition, Area Under Curve (AUC) were 0.96, 0.97, 0.97, and 0.94 respectively. For the prediction of lung metastasis, the accuracy of the T1W, FST2W, CT, and the fusion of T1W and FST2W test data were 0.92, 0.93, 0.88, and 0.91, respectively. The corresponding AUC values were 0.97, 0.96, 0.95, and 0.95, respectively. FST2W MRI performed best for predicting STS grading and lung metastasis.
CONCLUSION: MRI and CT images combined with the CNN model can be useful for making predictions regarding STS grading and lung metastasis, thus providing help for patient diagnosis and treatment.
引用
- Zhang L, Ren Z. Comparison of CT and MRI images for the prediction of soft-tissue sarcoma grading and lung metastasis via a convolutional neural networks model. Clin Radiol. 2019. PMID: 31575409. doi:10.1016/j.crad.2019.08.008