使用超高分辨率CT直接评估慢性阻塞性肺疾病的外周气道
研究利用体模确定超高分辨率CT可测量管腔的下限,并分析110例男性COPD患者的第3至6级气道。结果显示第6级气道多数内径小于2 mm,其管腔面积总和与气流受限关系最密切,提示该指标可作为反映COPD气流受限的CT生物标志物。
要点
- 超高分辨率CT可准确测量直径1-2 mm的外周气道,体模中直径≥1.3 mm管腔面积误差在±10%以内。
- 第6级RB1和RB10气道中分别有70%和62%内径小于2 mm,第6级气道数目随气流受限加重而减少。
- 第3至6级气道中,第6级气道管腔面积总和对气流受限影响最大。
核心结论
- 超高分辨率CT能够准确、直接地评估直径1-2 mm的外周气道;第6级气道内径常小于2 mm,其管腔面积总和可作为反映COPD气流受限的有用CT生物标志物。
研究设计与样本
- 体模实验结合COPD患者横断面分析;纳入110例男性COPD患者,行超高分辨率CT(1024×1024矩阵、0.25 mm层厚)及肺功能检查。
关键影像表现/征象
- 第6级RB1和RB10气道中分别有70%和62%内径小于2 mm。
- 第6级RB1和RB10气道数目随气流受限严重程度增加而减少。
诊断标准与关键数值
- 体模中直径≥1.3 mm管腔面积测量误差在±10%以内,直径1.0 mm管腔面积误差为-24%。
- 第3至6级气道中,第6级气道管腔面积总和对气流受限影响最大。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Disease in small airways <2 mm in diameter is a major pathology of chronic obstructive pulmonary disease (COPD). However, compared to airways <1 mm in diameter, the pathophysiological role of airways 1-2 mm in diameter remains unclear. This study analysed phantom and human COPD data to test the hypothesis that ultra-high-resolution computed tomography (U-HRCT) can accurately measure peripheral airways that are difficult to measure with conventional CT.
METHOD: The lower limit of lumen sizes measurable on U-HRCT was determined using phantom tubes. In the cross-sectional data of 110 males with COPD who underwent U-HRCT (1024 × 1024 matrix, 0.25 mm slice thickness) and spirometry, all 3rd (segmental) to 6th generation airways of the right apical and basal posterior bronchus (RB1 and RB10) were analysed.
RESULTS: The errors in measuring the lumen area (LA) of phantom tubes ≥1.3 and 1.0 mm in diameter were within ±10 and -24%, respectively. The internal diameters for 70 and 62% of the 6th generation RB1 and RB10 airways were <2 mm. The numbers of 6th generation RB1 and RB10 airways decreased as the airflow limitation severity increased. Among the mean LA and sum of LA(sum-LA) of the 3rd to 6th generation airways, the sum-LA of the 6th generation had the largest impact on airflow limitation.
CONCLUSIONS: U-HRCT enables accurate and direct evaluation of peripheral airways 1-2 mm in diameter. The 6th generation airways are commonly <2 mm in diameter, and the sum-LA can be a useful CT biomarker that reflects airflow limitation in COPD.
引用
- Tanabe N, Shima H, Sato S, et al. Direct evaluation of peripheral airways using ultra-high-resolution CT in chronic obstructive pulmonary disease. Eur J Radiol. 2019. PMID: 31574362. doi:10.1016/j.ejrad.2019.108687
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。