常规胸部CT测量三尖瓣环直径可检出显著三尖瓣反流
回顾性分析674例在CT前后24小时内接受超声心动图检查者的非心电门控胸部增强CT,测量三尖瓣环直径并以超声为参考标准。以≥41 mm为阈值预测中度及以上三尖瓣反流,AUC为0.92,特异度96.5%、敏感度75.7%,阴性预测值95.5%。作者认为阈值以上应建议进一步超声心动图评估。
要点
- 常规胸部增强CT上三尖瓣环直径≥41 mm预测中度及以上三尖瓣反流,特异度96.5%、敏感度75.7%。
- 显著三尖瓣反流总体患病率15.0%,男性10.7%、女性19.8%。
- 测量值低于阈值时阴性预测值达95.5%,可有效排除显著三尖瓣反流。
核心结论
- 以≥41 mm为阈值,常规胸部CT测量三尖瓣环直径可预测中度及以上三尖瓣反流,特异度96.5%、敏感度75.7%。
- 低于阈值的测量值阴性预测值为95.5%。
- 三尖瓣环直径可在常规胸部增强CT图像上测量,当高于阈值时作者建议进一步行超声心动图评估。
研究设计与样本
- 回顾性研究,纳入674例在CT前后24小时内接受超声心动图检查者。
- 采用非心电门控胸部增强CT图像,回顾性测量三尖瓣环直径。
- 以超声心动图报告为参考标准,采用定性、定量与客观指标相结合的多参数方法对三尖瓣反流分级。
- 三尖瓣反流分级为「中度」或「重度」视为显著,分级为「无反流」「微量」「极轻度」或「轻度」视为不显著。
关键影像表现/征象
- 在常规非心电门控胸部增强CT图像上可测量三尖瓣环直径。
诊断标准与关键数值
- 以CT三尖瓣环直径≥41 mm为阈值预测中度及以上三尖瓣反流,AUC为0.92(95%CI 0.89-0.96)。
- 阈值≥41 mm时特异度96.5%(95%CI 95.0-97.9%)、敏感度75.7%(95%CI 67.6-83.8%)。
- 阈值≥41 mm时阳性预测值80.2%、阴性预测值95.5%。
临床应用与阅片要点
- 在常规胸部增强CT上测量三尖瓣环直径,≥41 mm时作者建议进一步行超声心动图评估。
- 测量值低于41 mm时阴性预测值95.5%,可提示显著三尖瓣反流可能性低。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The objective of this study was to determine if moderate to severe tricuspid regurgitation (TR) can be predicted on routine non-ECG-gated CT images of the chest with contrast agent. MATERIALS AND METHODS. Non-ECG-gated CT images of the chest in 674 people who had undergone echocardiography within 24 hours of CT were retrospectively reviewed. CT images were reviewed, and measurements of the tricuspid annular diameter were recorded. Echocardiogram reports were independently reviewed, and the presence and severity of TR was recorded. TR was graded in a multiparametric approach using a combination of qualitative, quantitative, and objective measures. TR grades of either "moderate" or "severe" were considered significant, and grades reported as "no regurgitation," "trace," "trivial," or "mild" were considered insignificant. RESULTS. The overall prevalence of significant (moderate or severe) TR was 15.0% (10.7% prevalence in men and 19.8% in women). Using ≥ 41 mm as a cut point on CT, the prediction accuracy reached an AUC of 0.92 (95% CI, 0.89-0.96). Specificity was 96.5% (95% CI, 95.0-97.9%), sensitivity was 75.7% (95% CI, 67.6-83.8%), positive predictive value was 80.2%, and negative predictive value was 95.5%. CONCLUSION. Using a cut point of ≥ 41 mm, measurement of the tricuspid valve annulus on routine CT of the chest can predict moderate to severe TR with a specificity of 96.5% and sensitivity of 75.7%. Measurements below threshold had a 95.5% negative predictive value. Tricuspid annular diameter can be measured on routine contrast-enhanced CT images of the chest, and, when above threshold, further evaluation with echocardiography should be recommended.
引用
- Hassani C, Ng B, Cen S, et al. Tricuspid Annular Diameter Measurement on Routine Chest CT Can Detect Significant Tricuspid Regurgitation. AJR Am J Roentgenol. 2019. PMID: 31573854. doi:10.2214/AJR.19.21602
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。