基于CT的气道流模型评估慢性阻塞性肺疾病通气功能的初步研究
前瞻性纳入9例GOLD II-IV期COPD患者,用基于CT的全尺度气道网络(FAN)流模型计算肺通气分布,并与超极化氙129 MRI及锝99m-DTPA气溶胶SPECT通气显像比较。FAN模型通气与两种功能成像均呈强正相关(ρ=0.67与ρ=0.65,P<.001),提示该模型可提供区域肺通气信息。
要点
- FAN模型通气和129Xe MRI相关ρ=0.67(P<.001),和V-SPECT相关ρ=0.65(P<.001)。
- 肺叶通气比例与129Xe MRI相关ρ=0.67、与V-SPECT相关ρ=0.59(均P<.001)。
- FAN与129Xe MRI及V-SPECT的通气直方图χ2距离分别为0.16±0.08和0.28±0.14。
核心结论
- 基于CT的全尺度气道网络流模型可提供COPD的区域肺通气信息,并与超极化氙129 MRI及锝99m-DTPA气溶胶SPECT通气显像相关。
研究设计与样本
- 前瞻性研究,2017年5月至8月纳入9例GOLD II-IV期COPD患者(7男,平均年龄65岁±5;2女,平均年龄63岁±7),用FAN流模型计算肺通气,并与屏气时间序列129Xe MRI及V-SPECT功能成像数据比较。
诊断标准与关键数值
- FAN模型通气与129Xe MRI图像相关ρ=0.67(P<.001),与V-SPECT相关ρ=0.65(P<.001)。
- FAN与129Xe MRI及FAN与V-SPECT在感兴趣区通气直方图的χ2距离分别为0.16±0.08和0.28±0.14。
- FAN模型肺叶通气比例与129Xe MRI线性相关ρ=0.67(P<.001),与V-SPECT线性相关ρ=0.59(P<.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background The lack of functional information in thoracic CT remains a limitation of its use in the clinical management of chronic obstructive pulmonary disease (COPD). Purpose To compare the distribution of pulmonary ventilation assessed by a CT-based full-scale airway network (FAN) flow model with hyperpolarized xenon 129 (129Xe) MRI (hereafter, 129Xe MRI) and technetium 99m-diethylenetriaminepentaacetic acid aerosol SPECT ventilation imaging (hereafter, V-SPECT) in participants with COPD. Materials and Methods In this prospective study performed between May and August 2017, pulmonary ventilation in participants with COPD was computed by using the FAN flow model. The modeled pulmonary ventilation was compared with functional imaging data from breath-hold time-series 129Xe MRI and V-SPECT. FAN-derived ventilation images on the coronal plane and volumes of interest were compared with functional lung images. Percentage lobar ventilation estimated by the FAN model was compared with that measured at 129Xe MRI and V-SPECT. The statistical significance of ventilation distribution between FAN and functional images was demonstrated with the Spearman correlation coefficient and χ2 distance. Results For this study, nine participants (seven men [mean age, 65 years ± 5 {standard deviation}] and two women [mean age, 63 years ± 7]) with COPD that was Global Initiative for Chronic Obstructive Lung Disease stage II-IV were enrolled. FAN-modeled ventilation profile showed strong positive correlation with images from 129Xe MRI (ρ = 0.67; P < .001) and V-SPECT (ρ = 0.65; P < .001). The χ2 distances of the ventilation histograms in the volumes of interest between the FAN and 129Xe MRI and FAN and V-SPECT were 0.16 ± 0.08 and 0.28 ± 0.14, respectively. The ratios of lobar ventilations in the models were linearly correlated to images from 129Xe MRI (ρ = 0.67; P < .001) and V-SPECT (ρ = 0.59; P < .001). Conclusion A CT-based full-scale airway network flow model provided regional pulmonary ventilation information for chronic obstructive pulmonary disease and correlates with hyperpolarized xenon 129 MRI and technetium 99m-diethylenetriaminepentaacetic acid aerosol SPECT ventilation imaging. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Schiebler and Parraga in this issue.
引用
- Kim M, Doganay O, Matin TN, et al. CT-based Airway Flow Model to Assess Ventilation in Chronic Obstructive Pulmonary Disease: A Pilot Study. Radiology. 2019. PMID: 31617794. doi:10.1148/radiol.2019190395
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。