文献速递腹部泌尿生殖介入CTMR

关于用于MR引导在线自适应放疗的体素合成CT的准确性研究

On the accuracy of bulk synthetic CT for MR-guided online adaptive radiotherapy.
PubMed 文献 · Radiol Med · 2019-10-08

本研究对26例腹部和盆腔病变患者,将计划CT分割为空气、肺、脂肪、软组织和骨五个密度层级,分别用ICRU46推荐值和患者特异性中位相对电子密度值生成两种合成CT(sCTICRU与sCTtailor),并与计划CT比较剂量计算准确性。结果显示sCT与计划CT剂量吻合良好,sCTtailor的gamma通过率(1%/1mm)为93.7%±5.3%,高于sCTICRU的91.2%±6.9%;作者结论认为体素sCT在磁场存在下仍能保证高剂量计算准确性,适用于MRgRT,且使用患者特异性相对电子密度值可进一步提高准确性。

要点

  • 体素合成CT在磁场存在下仍能保证高水平的剂量计算准确性,适用于MR引导放疗。
  • 使用患者特异性相对电子密度值可提高合成CT的剂量计算准确性。
  • gamma通过率(1%/1mm)sCTtailor为93.7%±5.3%,sCTICRU为91.2%±6.9%。

核心结论

  • 体素合成CT在磁场存在下仍能保证高水平的剂量计算准确性,适用于MR引导在线自适应放疗;使用患者特异性相对电子密度值可提高该准确性。

研究设计与样本

  • 研究纳入26例腹部和盆腔病变患者,采集计划CT并分割为空气、肺、脂肪、软组织和骨五个密度层级,分别以ICRU46推荐相对电子密度值和患者特异性中位相对电子密度值生成sCTICRU和sCTtailor两种合成CT,在同一治疗计划下与计划CT比较剂量计算准确性。

诊断标准与关键数值

  • 剂量计算准确性以gamma分析和剂量体积直方图参数评价;gamma通过率(1%/1mm)sCTICRU为91.2%±6.9%,sCTtailor为93.7%±5.3%;V95(PTV)估计平均差异sCTtailor为0.2%、sCTICRU为1.2%(相对于计划CT值)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: MR-guided radiotherapy (MRgRT) relies on the daily assignment of a relative electron density (RED) map to allow the fraction specific dose calculation. One approach to assign the RED map consists of segmenting the daily magnetic resonance image into five different density levels and assigning a RED bulk value to each level to generate a synthetic CT (sCT). The aim of this study is to evaluate the dose calculation accuracy of this approach for applications in MRgRT.

METHODS: A planning CT (pCT) was acquired for 26 patients with abdominal and pelvic lesions and segmented in five levels similar to an online approach: air, lung, fat, soft tissue and bone. For each patient, the median RED value was calculated for fat, soft tissue and bone. Two sCTs were generated assigning different bulk values to the segmented levels on pCT: The sCTICRU uses the RED values recommended by ICRU46, and the sCTtailor uses the median patient-specific RED values. The same treatment plan was calculated on two the sCTs and the pCT. The dose calculation accuracy was investigated in terms of gamma analysis and dose volume histogram parameters.

RESULTS: Good agreement was found between dose calculated on sCTs and pCT (gamma passing rate 1%/1 mm equal to 91.2% ± 6.9% for sCTICRU and 93.7% ± 5.3% b or sCTtailor). The mean difference in estimating V95 (PTV) was equal to 0.2% using sCTtailor and 1.2% using sCTICRU, respect to pCT values CONCLUSIONS: The bulk sCT guarantees a high level of dose calculation accuracy also in presence of magnetic field, making this approach suitable to MRgRT. This accuracy can be improved by using patient-specific RED values.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Cusumano D, Placidi L, Teodoli S, et al. On the accuracy of bulk synthetic CT for MR-guided online adaptive radiotherapy. Radiol Med. 2019. PMID: 31591701. doi:10.1007/s11547-019-01090-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。