基于MRI影像组学、遗传和临床风险因素的机器学习技术改进高级别胶质瘤生存预测
研究纳入147例高级别胶质瘤患者(训练队列112例,独立测试队列35例),从CE-T1WI和T2FLAIR图像的肿瘤区和瘤周水肿区提取影像组学特征。由11个特征构建的影像组学标签将患者分为低危和高危组,联合影像组学标签、IDH和年龄的列线图进一步提高了总生存预测效能(训练队列C指数0.764,测试队列0.758)。
要点
- 由11个影像组学特征构建的标签可将高级别胶质瘤分为低危和高危组,训练队列C指数0.707,测试队列0.711。
- 多因素Cox回归显示影像组学标签(HR 2.18,P=0.005)、IDH(HR 0.490,P=0.007)和年龄(HR 1.039,P=0.005)为独立风险因素。
- 联合上述独立风险因素的列线图预测总生存的C指数在训练队列为0.764、测试队列为0.758。
核心结论
- 影像组学标签是高级别胶质瘤的新预后生物标志物;整合影像组学标签、IDH和年龄的列线图提高了总生存估计效能,可能成为胶质瘤治疗指南的新补充。
研究设计与样本
- 研究纳入147例有MRI图像、遗传数据和临床数据的高级别胶质瘤病例,其中112例为训练队列、35例为独立测试队列;从CE-T1WI和T2FLAIR图像的肿瘤区和瘤周水肿区提取影像组学特征,采用Kaplan-Meier生存分析和log rank检验探索关联,并以多因素Cox回归构建列线图。
诊断标准与关键数值
- 由11个影像组学特征构建的影像组学标签将患者分为低危和高危组,预测总生存的C指数在训练队列为0.707、测试队列为0.711;多因素Cox回归确定影像组学标签(HR 2.18,P=0.005)、IDH(HR 0.490,P=0.007)和年龄(HR 1.039,P=0.005)为独立风险因素;联合列线图预测总生存的C指数在训练队列为0.764、测试队列为0.758。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To develop a radiomic signature to predict overall survival (OS) for high-grade glioma (HGG), and construct a nomogram by combining selected radiomic, genetic and clinical risk factors to further improve the performance of the risk model.
MATERIALS AND METHODS: 147 cases of HGG with MRI images, genetic data, clinical data were studied, wherein 112 patients were used as training cohort, and 35 patients were as independent test cohort. Radiomics features were extracted from tumor area and peritumoral edema area on CE-T1WI and T2FLAIR images. Association between radiomics signature, genetic, clinical risk factors and OS was explored by Kaplan-Meier survival analysis and log rank test. The multivariate Cox regression analysis was trained with radiomic features along with selected genetic and clinical risk factors, which was presented as a nomogram.
RESULTS: The radiomic signature constructed by 11 radiomics features stratified patients into low- and high-risk groups, and the C-Index for OS prediction was 0.707 and 0.711 in training and test cohorts, respectively. The multivariable Cox regression analysis identified radiomics signature (hazard ratio (HR): 2.18, P = 0.005), IDH (HR: 0.490, P = 0.007) and age (HR: 1.039, P = 0.005) as independent risk factors. A nomogram combining these independent risk factors further improved the performance for OS estimation (C-index = 0.764 and 0.758 in training and test cohorts, respectively).
CONCLUSION: The radiomics signature is a new prognostic biomarker for HGG. A nomogram incorporating radiomics signature, IDH and age improved the performance of OS estimation, which might be a new complement to the treatment guidelines of glioma.
引用
- Tan Y, Mu W, Wang XC, et al. Improving survival prediction of high-grade glioma via machine learning techniques based on MRI radiomic, genetic and clinical risk factors. Eur J Radiol. 2019. PMID: 31606714. doi:10.1016/j.ejrad.2019.07.010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。