文献速递神经技术与安全CTMR

多序列MRI引导的深度特征融合模型用于CT图像中术后胶质瘤分割

Postoperative glioma segmentation in CT image using deep feature fusion model guided by multi-sequence MRIs.
PubMed 文献 · Eur Radiol · 2019-10-24

本研究开发了由多序列MRI引导的深度特征融合模型(DFFM),用于在CT图像上自动分割术后胶质瘤,共纳入59例术后胶质瘤(II级24例、III级18例、IV级17例)的CT和多序列MRI数据集。DFFM的Dice系数为0.836,显著高于仅用单CT训练的U-Net(0.713)和堆叠CT与多序列MRI训练的U-Net(0.818)(p < 0.01)。DFFM能实现准确的自动分割,可能有助于改进和促进放疗计划制定。

要点

  • DFFM在CT上自动分割术后胶质瘤的Dice系数为0.836,高于对照模型。
  • 多序列MRI引导可提升CT上深度学习分割术后胶质瘤的效果。
  • 该模型可能有助于在术后胶质瘤放疗计划中勾画GTV。

核心结论

  • DFFM能由多序列MRI引导,在CT图像上准确自动分割术后胶质瘤,可能改进和促进放疗计划制定。

研究设计与样本

  • 研究为开发深度特征融合模型(DFFM)的多序列MRI引导卷积神经网络(CNN),共纳入59例术后胶质瘤(II级24例、III级18例、IV级17例)的CT和多序列MRI(T1/T2加权FLAIR、T1加权增强、T2加权)数据集,以手动分割为参考,使用Dice系数(DSC)、精确率和召回率评价重叠度,采用Wilcoxon符号秩检验进行统计分析。

诊断标准与关键数值

  • DFFM的DSC为0.836,显著高于单CT训练的U-Net的0.713和堆叠CT与多序列MRI训练的U-Net的0.818(p < 0.01)。
  • 精确率表现与DSC相似。
  • DSC和精确率在不同级别间无显著统计学差异(p > 0.01)。

临床应用与阅片要点

  • 作者认为该模型可能有助于在术后胶质瘤放疗计划中勾画GTV。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Computed tomography (CT) and magnetic resonance imaging (MRI) are the most commonly selected methods for imaging gliomas. Clinically, radiotherapists always delineate the CT glioma region with reference to multi-modal MR image information. On this basis, we develop a deep feature fusion model (DFFM) guided by multi-sequence MRIs for postoperative glioma segmentation in CT images.

METHODS: DFFM is a multi-sequence MRI-guided convolutional neural network (CNN) that iteratively learns the deep features from CT images and multi-sequence MR images simultaneously by utilizing a multi-channel CNN architecture, and then combines these two deep features together to produce the segmentation result. The whole network is optimized together via a standard back-propagation. A total of 59 CT and MRI datasets (T1/T2-weighted FLAIR, T1-weighted contrast-enhanced, T2-weighted) of postoperative gliomas as tumor grade II (n = 24), grade III (n = 18), or grade IV (n = 17) were included. Dice coefficient (DSC), precision, and recall were used to measure the overlap between automated segmentation results and manual segmentation. The Wilcoxon signed-rank test was used for statistical analysis.

RESULTS: DFFM showed a significantly (p < 0.01) higher DSC of 0.836 than U-Net trained by single CT images and U-Net trained by stacking the CT and multi-sequence MR images, which yielded 0.713 DSC and 0.818 DSC, respectively. The precision values showed similar behavior as DSC. Moreover, DSC and precision values have no significant statistical difference (p > 0.01) with difference grades.

CONCLUSIONS: DFFM enables the accurate automated segmentation of CT postoperative gliomas of profit guided by multi-sequence MR images and may thus improve and facilitate radiotherapy planning.

KEY POINTS: • A fully automated deep learning method was developed to segment postoperative gliomas on CT images guided by multi-sequence MRIs. • CT and multi-sequence MR image integration allows for improvements in deep learning postoperative glioma segmentation method. • This deep feature fusion model produces reliable segmentation results and could be useful in delineating GTV in postoperative glioma radiotherapy planning.

来源:Eur Radiol,查看原文。版权归原作者所有。