指南与共识头颈技术与安全CT

基于动态多图谱选择的头颈部CT图像共识分割

Dynamic multiatlas selection-based consensus segmentation of head and neck structures from CT images.
指南 / 共识 · Med Phys · 2019-10-31

研究开发了动态多图谱选择方法用于头颈部危及器官的自动分割,通过图像级全局加权投票(GWV)或结构级结构加权投票(SWV)选择图谱并加权融合,在内部数据集45例和外部数据集32例头颈CT上与专家勾画比较,SWV和GWV的Dice相似系数均显著优于单最佳图谱和大数投票法(P<0.001)。

要点

  • SWV法对下颌骨DSC为0.85、口腔为0.88、脊髓为0.84,脑干和腮腺均为0.76。
  • SWV对下颌下腺DSC为0.60,优于GWV的0.52(P=0.019)。
  • 共识图可与分割结果联合显示图谱间的体素级一致性,便于人工复核。

核心结论

  • SWV和GWV方法生成的自动分割比单最佳图谱和大数投票法更准确,共识图可在人工复核时可视化危及器官内图谱间的体素级一致性。

研究设计与样本

  • 方法学研究,使用77例头颈CT图像,包括纪念斯隆-凯特琳癌症中心内部数据集45例和外部数据集32例,以专家勾画为参考标准,采用Dice相似系数、Hausdorff距离、Hausdorff距离第95百分位数、最大表面距离中位数和体积比误差进行评价,DSC比较采用Wilcoxon秩和检验。

诊断标准与关键数值

  • SWV法DSC:口腔0.88、下颌骨0.85、脊髓0.84、脑干0.76、腮腺0.76、喉0.71、下颌下腺0.60。
  • SWV与GWV在下颌下腺的DSC分别为0.60和0.52(P=0.019),SWV更优。
  • SWV和GWV对所有危及器官的DSC均显著优于单最佳图谱(P<0.001)和大数投票法(P<0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Manual delineation of head and neck (H&N) organ-at-risk (OAR) structures for radiation therapy planning is time consuming and highly variable. Therefore, we developed a dynamic multiatlas selection-based approach for fast and reproducible segmentation.

METHODS: Our approach dynamically selects and weights the appropriate number of atlases for weighted label fusion and generates segmentations and consensus maps indicating voxel-wise agreement between different atlases. Atlases were selected for a target as those exceeding an alignment weight called dynamic atlas attention index. Alignment weights were computed at the image level and called global weighted voting (GWV) or at the structure level and called structure weighted voting (SWV) by using a normalized metric computed as the sum of squared distances of computed tomography (CT)-radiodensity and modality-independent neighborhood descriptors (extracting edge information). Performance comparisons were performed using 77 H&N CT images from an internal Memorial Sloan-Kettering Cancer Center dataset (N = 45) and an external dataset (N = 32) using Dice similarity coefficient (DSC), Hausdorff distance (HD), 95th percentile of HD, median of maximum surface distance, and volume ratio error against expert delineation. Pairwise DSC accuracy comparisons of proposed (GWV, SWV) vs single best atlas (BA) or majority voting (MV) methods were performed using Wilcoxon rank-sum tests.

RESULTS: Both SWV and GWV methods produced significantly better segmentation accuracy than BA (P < 0.001) and MV (P < 0.001) for all OARs within both datasets. SWV generated the most accurate segmentations with DSC of: 0.88 for oral cavity, 0.85 for mandible, 0.84 for cord, 0.76 for brainstem and parotids, 0.71 for larynx, and 0.60 for submandibular glands. SWV's accuracy exceeded GWV's for submandibular glands (DSC = 0.60 vs 0.52, P = 0.019).

CONCLUSIONS: The contributed SWV and GWV methods generated more accurate automated segmentations than the other two multiatlas-based segmentation techniques. The consensus maps could be combined with segmentations to visualize voxel-wise consensus between atlases within OARs during manual review.

来源:Med Phys,查看原文。版权归原作者所有。

引用

  1. Haq R, Berry SL, Deasy JO, et al. Dynamic multiatlas selection-based consensus segmentation of head and neck structures from CT images. Med Phys. 2019. PMID: 31587300. doi:10.1002/mp.13854

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。