使用新型双机器人X射线系统的踝关节三维锥形束CT:图像质量与辐射剂量评估
研究对16例尸体踝关节分别采用新型双机器人X射线系统的标准剂量(FD)和低剂量(LD)锥形束CT(CBCT)协议,并与临床多排CT(MSCT)协议对比。三位放射科医生评估图像质量、噪声和伪影。MSCT整体图像质量优于CBCT,但两种CBCT协议在多数研究中提供很好图像质量,适合临床踝关节成像,且辐射剂量最多比MSCT低五倍。
要点
- MSCT整体图像质量优于LD CBCT,两位读者也认为优于FD CBCT。
- FD和LD CBCT的软组织噪声和伪影均比MSCT更严重。
- FD和LD CBCT的CTDIvol均显著低于临床MSCT。
核心结论
- 尽管MSCT整体图像质量优于双机器人X射线系统的CBCT模式,但两种锥形束协议在多数研究中提供很好图像质量,适合临床踝关节成像。
- 标准剂量和尤其低剂量CBCT研究的辐射剂量最多比MSCT成像低五倍。
研究设计与样本
- 研究类型为采用尸体踝关节的影像质量与辐射剂量对比研究。
- 样本量为16例尸体踝关节。
- 设备与序列:新型双机器人X射线系统的CBCT模式(标准剂量FD和低剂量LD协议),对比临床协议的多排CT(MSCT)。
- 由三位放射科医生采用五分Likert量表评估骨与软组织的图像质量、噪声和伪影(1=图像质量差、噪声或伪影强;5=图像质量极好、噪声或伪影极小)。
- 辐射剂量比较采用容积CT剂量指数(CTDIvol)。
诊断标准与关键数值
- 整体图像质量被读者1/2/3描述为很好或极好的比例:LD为62.5/87.5/56.3%,FD为87.5/87.5/81.3%,MSCT为100/87.5/87.5%。
- 读者一致认为MSCT图像质量优于LD(读者1/2/3;p≤0.008),两位读者也发现MSCT优于FD(读者1/3;p≤0.034)。
- 软组织噪声和伪影在FD更强(所有p≤0.002),在LD也更强(所有p≤0.001);骨内伪影和噪声在LD更严重(所有p<0.001),在FD也更严重(所有p≤0.003)。
- CTDIvol:无剂量调制的临床MSCT扫描为15.0±0.0 mGy,高于FD的5.3±1.0 mGy和LD的2.9±0.6 mGy(两者p<0.001)。
临床应用与阅片要点
- 两种CBCT协议在多数研究中提供很好图像质量,适合临床踝关节成像。
- 标准剂量和尤其低剂量CBCT研究的辐射剂量最多比MSCT成像低五倍。
- 需注意FD和LD CBCT的软组织噪声和伪影比MSCT更严重,骨内伪影和噪声在LD和FD也更严重。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate image quality (IQ) and radiation dose in cone-beam computed tomography (CBCT) of the ankle using a novel twin robotic X-ray system.
METHOD: We examined 16 cadaveric ankles with standard-dose (FD) and low-dose (LD) protocols using the new system's CBCT mode. For comparison, we performed multi-slice CT imaging (MSCT) with a clinical protocol. Three radiologists assessed IQ, noise and artifacts in bone and soft tissue on a five-point Likert scale (1= poor IQ; strong noise or artifacts; 5= excellent IQ; minimal noise or artifacts). Volume CT dose indices (CTDIvol) were calculated for radiation dose comparison between CBCT and MSCT.
RESULTS: Overall IQ was described as very good or excellent by reader 1/2/3 in 62.5/87.5/56.3% of LD, 87.5/87.5/81.3% of FD and 100/87.5/87.5% of MSCT studies. Readers agreed that IQ was better in MSCT than LD (R1/R2/R3; p ≤ 0.008), two also found advantages of MSCT over FD (R1/R3; p ≤ 0.034). Soft tissue noise and artifacts were stronger in FD (all p ≤ 0.002) and LD (all p ≤ 0.001). In bone, artifacts and noise were also more severe in LD (all p < 0.001) and FD (all p ≤ 0.003). CTDIvol for clinical MSCT scans without dose modulation (15.0 ± 0.0 mGy) were higher than for FD (5.3 ± 1.0 mGy) and LD studies (2.9 ± 0.6 mGy; both p < 0.001).
CONCLUSIONS: Despite MSCT providing better overall IQ than the twin robotic X-ray system's CBCT mode, both cone-beam protocols offer very good IQ in most studies and are suitable for clinical ankle imaging. Standard-dose and especially low-dose CBCT studies deliver up to five times less radiation dose than MSCT imaging.
引用
- Grunz JP, Kunz AS, Gietzen CH, et al. 3D cone-beam CT of the ankle using a novel twin robotic X-ray system: Assessment of image quality and radiation dose. Eur J Radiol. 2019. PMID: 31520930. doi:10.1016/j.ejrad.2019.108659
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。