文献速递儿科影像技术与安全DR

法国儿童影像患者剂量多中心调查及更新诊断参考水平的建议:第2部分——平片摄影与诊断性透视

Multicentre survey on patient dose in paediatric imaging and proposal for updated diagnostic reference levels for France. Part 2: plain radiography and diagnostic fluoroscopy.
PubMed 文献 · Eur Radiol · 2019-09-16

法国放射学会、儿童影像学会与IRSN联合开展多中心调查,收集2015—2016年16个影像科室0—15岁儿童的平片摄影与诊断性透视剂量报告,以各操作、各年龄组中位值的第3四分位数提出新诊断参考水平,发现透视剂量机构间差异明显,原有平片国家诊断参考水平已过时。

要点

  • 平片摄影原有国家诊断参考水平已过时,本次结果已被法国当局用于更新。
  • 诊断性透视患者暴露在机构间差异明显,即使在习惯儿科操作的科室间亦如此。
  • 新诊断参考水平按每项操作和每个年龄组分别提出,以中位值分布的第3四分位数计算。

核心结论

  • 适用于平片摄影的国家诊断参考水平已过时,法国当局已据本研究结果更新;诊断性透视剂量差异大,新国家诊断参考水平有助于优化诊断实践。

研究设计与样本

  • 法国放射学会、儿童影像学会与IRSN开展的多中心剂量调查,自愿参加,16个影像科室,收集2015—2016年0—15岁儿童四项平片摄影和三项诊断性透视操作的剂量报告,每项操作每中心每年龄组至少记录10例患者的空气比释动能-面积乘积(PKA)。

诊断标准与关键数值

  • 新诊断参考水平按每项操作和每个年龄组提出,以各中心中位值分布的第3四分位数计算;共获得2249例平片摄影检查和1235例诊断性透视操作的剂量结果。

临床应用与阅片要点

  • 作者认为新国家诊断参考水平将有助于优化诊断实践,并指出诊断性透视中即使习惯儿科操作的科室间剂量差异也较大。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To report on a dose survey conducted by the French societies of radiology and paediatric imaging (SFR and SFIPP) and the French public service expert in nuclear and radiological risks (IRSN), and to suggest new diagnostic reference levels (DRLs) for paediatric plain radiography and diagnostic fluoroscopy.

METHODS: Dose reports concerning four radiography procedures and three diagnostic fluoroscopy procedures performed in 2015-2016 on children aged 0-15 years were collected from 16 imaging departments on a voluntary basis. Air kerma-area product (PKA) was recorded for at least 10 patients per procedure, per centre and per age group. New DRLs were calculated as the 3rd quartiles of the distributions of the median values.

RESULTS: Results from 2249 radiography examinations and 1235 diagnostic fluoroscopy procedures were obtained. A noticeable variability in patient exposure between facilities was observed in diagnostic fluoroscopy and to a lesser extent in plain radiography. DRLs are proposed for each procedure and each age group.

CONCLUSIONS: This study showed that the applicable national DRLs in plain radiography were obsolete and its results have been recently used by the French authorities to update them. In diagnostic fluoroscopy, large differences of doses were observed, even among departments accustomed to paediatric procedures. The new national DRLs will be useful for optimising diagnostic practice.

KEY POINTS: • New national diagnostic reference levels (DRLs) are proposed for several paediatric procedures in plain radiography and diagnostic fluoroscopy. • Even between departments accustomed to paediatric procedures, substantial differences of practice were observed, especially in diagnostic fluoroscopy.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Célier D, Roch P, Etard C, et al. Multicentre survey on patient dose in paediatric imaging and proposal for updated diagnostic reference levels for France. Part 2: plain radiography and diagnostic fluoroscopy. Eur Radiol. 2019. PMID: 31529249. doi:10.1007/s00330-019-06406-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。