泰迪熊比例模拟磁共振扫描仪对儿童及家长焦虑水平的影响
一项为期1年的前瞻性前后对照研究,在大学医院儿科放射科安装模拟MR扫描仪前后,评估91名4–16岁儿童及家长在非全麻MRI中的焦虑水平(视觉模拟量表0–100)。安装后儿童在准备室认为环境更放松的比例为50% vs 20%(P=0.004),解释后儿童焦虑显著降低(尤其女孩),家长焦虑在检查结束时显著降低,运动伪影率更低(1.7% vs 4.7%,P=0.04)。
要点
- 模拟MR扫描仪安装后,儿童认为准备室环境更放松的比例为50% vs 20%(P=0.004)。
- 安装后儿童在解释后焦虑水平显著降低,尤其女孩;家长焦虑在检查结束时显著降低。
- 安装后运动伪影率更低(1.7% vs 4.7%,P=0.04)。
核心结论
- 模拟扫描仪是提高解释效率、降低儿童焦虑和减少儿科MRI运动伪影的有效工具。
研究设计与样本
- 为期1年的前瞻性前后对照研究,在大学医院儿科放射科安装模拟MR扫描仪前后进行。
- 共纳入91名儿童及其家长,儿童中位年龄8岁(标准差=2)。
- 焦虑由4–16岁儿童及家长在三个时间点用视觉模拟量表自评(0=完全放松,100=极度紧张):候诊室、MRI技师解释后的准备室、MR采集图像出具时。
- 两组比较:一组有模拟MR扫描仪,另一组无;采用方差分析(ANOVA)和Fisher精确检验,并研究运动伪影。
关键影像表现/征象
- 模拟扫描仪安装后,儿童认为准备室氛围显著更放松的比例为50% vs 20%(P=0.004)。
- 模拟扫描仪安装后,儿童在解释后焦虑水平显著降低,尤其女孩;家长焦虑水平不变。
- 检查结束时家长焦虑水平显著降低。
- 运动伪影率更低(1.7% vs 4.7%,P=0.04)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Pediatric magnetic resonance imaging (MRI) can be stressful. Mock MR scanners have been proven to be effective in avoiding the use of general anesthesia.
OBJECTIVES: We prospectively evaluated the impact of a teddy bear-scale model of a mock MR scanner on the anxiety experienced by parents and their children during MRI without general anesthesia .
MATERIALS AND METHODS: A 1-year prospective study before and after the installation of a mock scanner in a Pediatric Radiology Department of a university hospital. Anxiety levels were self-estimated by children ages 4 to 16 years and by the parents with a visual analogue scale (from 0, completely relaxed, to 100, extremely stressed) at three moments: in the waiting room, in the preparation room after an explanation by the MRI technologists, and at the issue of the MR acquisition images. Two groups were tested: one with a mock MR scanner, the other without. Analysis of variance (ANOVA) and Fisher exact tests were performed. Motion artifacts were studied.
RESULTS: Ninety-one children and their parents were included. The median age was 8 years (standard deviation [SD]=2). In the post mock period, the ambiance of the preparation room was considered by children as significantly more relaxing in 50% vs. 20% (P=0.004) and the anxiety level of children was significantly lower after the explanation, particularly in girls, but unchanged for their parents. The anxiety levels at the end of the examination were significantly lower for parents. The motion artifacts rate was lower (1.7% vs. 4.7%, P=0.04).
CONCLUSION: A mock scanner was an efficient tool to improve efficiency of the explanation and to decrease anxiety in children and motion artifacts in pediatric MRI.
引用
- Morel B, Andersson F, Samalbide M, et al. Impact on child and parent anxiety level of a teddy bear-scale mock magnetic resonance scanner. Pediatr Radiol. 2019. PMID: 31501961. doi:10.1007/s00247-019-04514-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。