文献速递神经外周血管CT

CT血管造影侧支循环状态与CT灌注组织存活性的关系

Relationship between CT angiography-derived collateral status and CT perfusion-derived tissue viability.
PubMed 文献 · Clin Radiol · 2019-09-05

本研究纳入大脑中动脉M1/M2段和/或颈内动脉闭塞且发病12小时内的患者,用CTA最大密度投影图像对侧支循环进行0-3级分级,用CTP定义梗死核心(rCBF<30%或Tmax>10/12/14秒)和缺血半暗带(Tmax>6秒)。52例符合标准患者中,侧支分级与rCBF<30%定义的梗死核心(ρ=-0.814)及基于rCBF<30%与Tmax>6秒的错配比(ρ=0.945)相关性最好。

要点

  • 侧支循环良好者梗死核心更小、错配比更高。
  • rCBF<30%定义的梗死核心与侧支分级相关性优于Tmax阈值定义。
  • rCBF<30%与Tmax>6秒定义的错配比与侧支分级相关性最佳。

核心结论

  • 侧支循环良好的患者梗死核心更小、错配比更高;rCBF<30%定义的梗死体积及rCBF<30%与Tmax>6秒定义的错配比似乎与急性缺血性卒中患者的侧支循环相关性更好。

研究设计与样本

  • 纳入大脑中动脉M1/M2段和/或颈内动脉闭塞且发病12小时内的患者共83例,其中52例符合纳入标准;在CTA最大密度投影图像上对侧支循环进行0-3级分级,以CTP定义梗死核心和缺血半暗带。

关键影像表现/征象

  • 侧支循环分级与rCBF<30%定义的梗死核心呈负相关(ρ=-0.814,p<0.01)。
  • 基于rCBF<30%与Tmax>6秒定义的错配比与侧支循环分级呈正相关(ρ=0.945,p<0.01)。
  • rCBF<30%定义的梗死核心与侧支分级的相关性优于Tmax>10秒、>12秒或>14秒定义的梗死核心。

诊断标准与关键数值

  • 侧支循环在CTA最大密度投影图像上分为0-3级。
  • 梗死核心定义为rCBF<30%或Tmax>10秒、>12秒或>14秒的区域。
  • 缺血半暗带定义为Tmax>6秒的区域。

临床应用与阅片要点

  • 阅片时可结合CTA侧支分级与CTP参数评估梗死核心和错配比。
  • rCBF<30%定义的梗死核心及rCBF<30%与Tmax>6秒定义的错配比似乎与侧支循环相关性更好。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To explore the relationship between computed tomography (CT) angiography (CTA)-derived collateral status and CT perfusion (CTP)-derived tissue viability.

MATERIALS AND METHODS: Patients having middle cerebral artery (MCA) M1/M2 segment and/or internal carotid artery (ICA) occlusion and within 12 hours of onset were included. Collateral was graded from 0 to 3 on maximum intensity projection (MIP) images of CTA. The area with relative cerebral blood flow (rCBF) <30% or time-to-maximum (Tmax) >10 or >12 or >14 seconds was defined as the infarct core, and Tmax >6 seconds as the penumbra. Kruskal-Wallis and Spearman's correlation tests were performed to assess the correlation between collateral grade and infarct size or mismatch ratio.

RESULTS: Eighty-three patients were enrolled and 52 of them met the inclusion criteria. Infarct size defined by rCBF <30% or Tmax >10 or >12 or >14 seconds and mismatch ratios were significantly different among the four groups. The correlation between collateral grades and infarct core using rCBF <30% (ρ=-0.814, p<0.01) was better than that defined by Tmax >10s, >12s or >14s. Mismatch ratio for the infarct core defined by rCBF <30% (ρ=0.945, p<0.01) had the best correlation with collateral grades.

CONCLUSION: Patients with good collaterals show a smaller infarct core and higher mismatch ratio. Infarct size defined by rCBF <30% and mismatch ratio defined by rCBF <30% and Tmax >6 seconds appear to be more correlated with collaterals in AIS patients.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Xia Q, Wang X, Zhang Z, et al. Relationship between CT angiography-derived collateral status and CT perfusion-derived tissue viability. Clin Radiol. 2019. PMID: 31495547. doi:10.1016/j.crad.2019.07.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。