血流动力学显著型颈动脉狭窄中的螺旋血流
研究用双功能超声检查23例患者共25处血流动力学显著(65.0%,范围63.0%-69.0%)的颈内动脉狭窄,观察螺旋血流的特征。结果显示螺旋血流在狭窄后段最常见(68%),狭窄最窄处为48%,狭窄前段仅16%;狭窄最窄处轴向分量时间平均最大流速为88.5 cm/s(25th-75th百分位数73.8-127.8 cm/s),旋转分量为33.1 cm/s(22.7-40.9 cm/s),螺旋路径综合流速为92.2 cm/s(75.7-144.2 cm/s)。结论认为多普勒超声可检出动脉粥样硬化性狭窄中的螺旋血流,且其检出率在通过狭窄段时增加。
要点
- 螺旋血流在颈内动脉狭窄后段最常见(68%),狭窄最窄处为48%,狭窄前段仅16%。
- 狭窄最窄处轴向分量时间平均最大流速为88.5 cm/s(25th-75th百分位数73.8-127.8 cm/s),旋转分量为33.1 cm/s(22.7-40.9 cm/s)。
- 螺旋路径综合流速为92.2 cm/s(75.7-144.2 cm/s)。
核心结论
- 多普勒超声可检出动脉粥样硬化性狭窄中的螺旋血流,且其检出率在通过颈内动脉狭窄段时增加。
研究设计与样本
- 研究纳入23例患者共25处血流动力学显著(65.0%,范围63.0%-69.0%)的颈内动脉狭窄,采用双功能超声检查;狭窄严重程度按欧洲颈动脉外科试验分级方法经B型超声横断面扫描计算;旋转分量在彩色血流成像中于血管最窄处及狭窄前、后段横断面扫描评估;螺旋血流定量评估基于纵向和横向血管腔的脉冲波多普勒成像。
关键影像表现/征象
- 螺旋血流在颈内动脉狭窄后段最常见(68%),表现为单涡流(52%)或双涡流(16%)。
- 狭窄最窄处螺旋血流检出率为48%(单涡流44%,双涡流4%)。
- 狭窄前段螺旋血流检出率仅16%(单涡流8%,双涡流8%)。
诊断标准与关键数值
- 狭窄严重程度采用欧洲颈动脉外科试验分级方法,经B型超声横断面扫描计算。
- 螺旋血流在彩色血流成像中通过横断面扫描血管最窄处及狭窄前、后段评估旋转分量。
- 螺旋血流定量评估基于纵向和横向血管腔的脉冲波多普勒成像。
- 狭窄最窄处轴向分量时间平均最大流速为88.5 cm/s(25th-75th百分位数73.8-127.8 cm/s),旋转分量为33.1 cm/s(22.7-40.9 cm/s)。
- 螺旋路径综合流速为92.2 cm/s(75.7-144.2 cm/s)。
临床应用与阅片要点
- 原文结论指出多普勒超声可检出动脉粥样硬化性狭窄中的螺旋血流,且其检出率在通过颈内动脉狭窄段时增加。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To define helical blood flow (HBF) characteristics in hemodynamically significant atherosclerotic stenosis of the internal carotid artery (ICA) by means of duplex scanning.
METHODS: Twenty-five hemodynamically significant (65.0% [range, 63.0%-69.0%]) carotid stenoses were examined in 23 patients. The severity of the stenosis was calculated by the European Carotid Surgery Trial grading method by transverse section scanning in the B-mode. Rotational components were estimated in color flow mapping by transverse-section scanning of a vessel at the most narrowed site, as well as in the prestenotic and poststenotic segments. A quantitative evaluation of HBF was performed on the basis of pulsed wave Doppler imaging of longitudinal and transverse sections of the arterial lumen.
RESULTS: Helical blood flow was most often (68%) registered in the poststenotic segment of the ICA as a single vortex (52%) or double vortices (16%). At the most narrowed site, HBF was registered in 48% of the cases (44% single vortex and 4% double vortices), whereas in the prestenotic segment of the blood vessel, it was registered in only 16% of the cases (8% single vortex and 8% double vortices). The time-averaged maximum blood flow velocities at the most narrowed site were 88.5 cm/s (25th-75th percentiles, 73.8-127.8 cm/s) for the axial component and 33.1 cm/s (22.7-40.9 cm/s) for the rotational component. The calculated summary velocity of motion of the blood particles in helical paths was 92.2 cm/s (75.7-144.2 cm/s).
CONCLUSIONS: It has been shown that HBF can be registered by Doppler ultrasound in atherosclerotic stenosis, and its registration rate increases while passing through the narrowed segment of the ICA.
引用
- Kirsanov RI, Kulikov VP. Helical Blood Flow in Hemodynamically Significant Carotid Stenosis. J Ultrasound Med. 2019. PMID: 31502308. doi:10.1002/jum.15131
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。