文献速递骨肌MRUS

磁共振成像与自由手三维超声对自由跟腱形态及三维几何的估测相似

Magnetic Resonance Imaging and Freehand 3-D Ultrasound Provide Similar Estimates of Free Achilles Tendon Shape and 3-D Geometry.
PubMed 文献 · Ultrasound Med Biol · 2019-08-27

本研究纳入14名精英/次精英中距离跑者,比较磁共振成像(MRI)与自由手三维超声(3-DUS)重建自由跟腱形态与三维几何的相似性。两种方法在跟腱体积、长度和平均横截面积上一致性良好,沿腱长各位置横截面积无显著差异,作者认为二者可能等效。

要点

  • 自由手3-DUS与MRI重建的自由跟腱形态相似,Jaccard指数0.76±0.05、Hausdorff距离2.70±0.70 mm、RMSE 0.61±0.10 mm。
  • 3-DUS较MRI高估体积30.6±15.8 mm3(1.1%±0.6%)、长度0.3±0.7 mm(0.6%±1.9%)、平均横截面积0.3±1.42 mm2(0.4%±2.0%)。
  • 沿腱长各位置横截面积在两种成像方法间无显著差异。

核心结论

  • MRI与自由手3-DUS可能被视为估测自由跟腱形态和三维几何的等效方法,3-DUS因可在实验室环境及等长负荷下评估而成为有吸引力的替代选择。

研究设计与样本

  • 研究纳入14名精英/次精英中距离跑者,分别在两次独立成像 session 采集跟腱MRI与3-DUS,所有三维重建采用相同方法,以Bland-Altman分析评估体积、长度和平均横截面积的一致性。

关键影像表现/征象

  • 自由跟腱形态相似性:Jaccard指数0.76±0.05,Hausdorff距离2.70±0.70 mm,RMSE 0.61±0.10 mm。
  • 与MRI相比,3-DUS高估体积30.6±15.8 mm3(1.1%±0.6%)、长度0.3±0.7 mm(0.6%±1.9%)、平均横截面积0.3±1.42 mm2(0.4%±2.0%)。
  • 沿腱长各位置横截面积在两种成像方法间无显著差异。

诊断标准与关键数值

  • 体积一致性界限:-0.4至61.7 mm3(-0.2%至2.3%)。
  • 长度一致性界限:-1.0至1.5 mm(-3.2%至4.5%)。
  • 平均横截面积一致性界限:-2.5至3.1 mm2(-3.5%至4.3%)。

临床应用与阅片要点

  • 作者认为MRI与自由手3-DUS可能为估测自由跟腱形态和三维几何的等效方法。
  • 作者认为3-DUS可在实验室环境及等长负荷下评估跟腱三维形态与几何,是未来研究中评估自由跟腱宏观结构的有吸引力替代选择。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

The purpose of this study was to assess the similarity of free Achilles tendon shape and 3-D geometry between magnetic resonance imaging (MRI) and freehand 3-D ultrasound (3-DUS) imaging methods. Fourteen elite/sub-elite middle-distance runners participated in the study. MRI and 3-DUS scans of the Achilles tendon were acquired on two separate imaging sessions, and all 3-D reconstructions were performed using identical methods. Shape similarity of free Achilles tendon reconstructed from MRI and 3-DUS data was assessed using Jaccard index, Hausdorff distance and root mean square error (RMSE). The Jaccard index, Hausdorff distance and RMSE values were 0.76 ± 0.05, 2.70 ± 0.70 and 0.61 ± 0.10 mm, respectively. The level of agreement between MRI and 3-DUS for free Achilles tendon volume, length and average cross-sectional area (CSA) was assessed using Bland-Altman analysis. Compared to MRI, freehand 3-DUS overestimated volume, length and average CSA by 30.6 ± 15.8 mm3 (1.1% ± 0.6%), 0.3 ± 0.7 mm (0.6% ± 1.9%) and 0.3 ± 1.42 mm2 (0.4% ± 2.0%), respectively. The upper and lower limits of agreement between MRI and 3-DUS for volume, length and average CSA were -0.4 to 61.7 mm3 (-0.2% to 2.3%), -1.0 to 1.5 mm (-3.2% to 4.5%) and -2.5 to 3.1 mm2 (-3.5% to 4.3%), respectively. There were no significant differences between imaging methods in CSA along the length of the tendon. In conclusion, MRI and freehand 3-DUS may be considered equivalent methods for estimating shape and 3-D geometry of the free Achilles tendon. These findings, together with the practical benefits of being able to assess 3-D Achilles tendon shape and geometry in a laboratory environment and under isometric loading, make 3-DUS an attractive alternative to MRI for assessing 3-D free Achilles tendon macro-structure in future studies.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Devaprakash D, Lloyd DG, Barrett RS, et al. Magnetic Resonance Imaging and Freehand 3-D Ultrasound Provide Similar Estimates of Free Achilles Tendon Shape and 3-D Geometry. Ultrasound Med Biol. 2019. PMID: 31471069. doi:10.1016/j.ultrasmedbio.2019.07.679

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。