文献速递骨肌MRDR

DWI与ADC对绝经后患者骨质疏松诊断的敏感度和特异度评估

Sensitivity and specificity assessment of DWI and ADC for the diagnosis of osteoporosis in postmenopausal patients.
PubMed 文献 · Radiol Med · 2019-09-17

前瞻性纳入60例绝经后女性,对L2–L4共180个椎体行DEXA与MRI检查,按骨密度分为正常52个、骨量减少92个、骨质疏松36个椎体。骨质疏松组ADC值135.67±44.10×10⁻⁶ mm²/s显著低于正常组561.85±190.37×10⁻⁶ mm²/s(P=0.0001),ADC与BMD正相关(r=0.748,P=0.0001),ROC曲线下面积0.912(P=0.001);以400 mm²/s为阈值诊断骨质疏松的敏感度90.90%、特异度83.34%、准确率88.89%、阳性预测值93.75%、阴性预测值76.93%。

要点

  • 骨质疏松椎体ADC值显著低于正常椎体,ADC与BMD呈正相关(r=0.748)。
  • 以ADC 400 mm²/s为阈值诊断骨质疏松,敏感度90.90%、特异度83.34%、准确率88.89%。
  • DWI可对绝经后女性骨髓改变及骨质疏松进行定量评估。

核心结论

  • 女性ADC值与BMD呈正相关,DWI可对绝经后女性骨髓改变及骨质疏松进行定量评估。

研究设计与样本

  • 前瞻性研究,纳入60例绝经后女性(平均年龄60.2±6.11岁),对L2–L4共180个腰椎行DEXA与MRI检查。
  • 依据DEXA骨密度测量将椎体分为正常组52个、骨量减少组92个、骨质疏松组36个。
  • 对椎体行DWI检查评估表观扩散系数(ADC),比较三组ADC值并与BMD做相关性分析,采用ROC分析评估诊断效能。

关键影像表现/征象

  • 骨质疏松组ADC值135.67±44.10×10⁻⁶ mm²/s显著低于正常组561.85±190.37×10⁻⁶ mm²/s(P=0.0001)。

诊断标准与关键数值

  • ADC与BMD呈正相关(r=0.748,P=0.0001)。
  • ROC分析中DWI的曲线下面积为0.912(P=0.001)。
  • 以400 mm²/s为诊断骨质疏松的阈值,敏感度90.90%、特异度83.34%、准确率88.89%、阳性预测值93.75%、阴性预测值76.93%。

临床应用与阅片要点

  • ADC值可与BMD联合用于绝经后女性椎体骨髓改变及骨质疏松的定量评估。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: In this study, we prospectively investigated the diagnostic capability of diffusion-weighted magnetic resonance imaging (DWI) in assessing vertebral marrow changes in postmenopausal women with osteoporosis.

MATERIALS AND METHODS: Sixty postmenopausal women (mean age 60.2 ± 6.11 years) underwent both dual-energy X-ray absorptiometry (DEXA) of the spine and MRI. Results were acquired from each patient's L2 to L4, for a total of 180 lumbar vertebrae. Based on bone mineral density (BMD) measurements obtained from DEXA, the vertebrae were divided into three groups as follows: normal (n = 52), osteopenic (n = 92), and osteoporotic (n = 36). DWI of the vertebral body was performed to assess the apparent diffusion coefficient (ADC). The ADC outcomes were compared among the three groups and correlated with BMD.

RESULTS: ADC values (× 10-6 mm2/s) were significantly lower in the osteoporotic group (135.67 ± 44.10) in comparison to the normal group (561.85 ± 190.37) (P = 0.0001). The results showed a positive correlation between ADC and BMD values (r = 0.748, P = 0.0001). In receiver operating characteristic (ROC) analysis, the area under the curve for DWI was 0.912 (P = 0.001). A cut-off value of 400 mm2/s for the diagnosis of osteoporosis; had sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of 90.90%, 83.34%, 88.89%, 93.75%, and 76.93%, respectively.

CONCLUSION: ADC values correlated positively with BMD in women. DWI can allow quantitative evaluation of bone marrow changes and osteoporosis in postmenopausal women.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Momeni M, Asadzadeh M, Mowla K, et al. Sensitivity and specificity assessment of DWI and ADC for the diagnosis of osteoporosis in postmenopausal patients. Radiol Med. 2019. PMID: 31531809. doi:10.1007/s11547-019-01080-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。