DWI与ADC对绝经后患者骨质疏松诊断的敏感度和特异度评估
前瞻性纳入60例绝经后女性,对L2–L4共180个椎体行DEXA与MRI检查,按骨密度分为正常52个、骨量减少92个、骨质疏松36个椎体。骨质疏松组ADC值135.67±44.10×10⁻⁶ mm²/s显著低于正常组561.85±190.37×10⁻⁶ mm²/s(P=0.0001),ADC与BMD正相关(r=0.748,P=0.0001),ROC曲线下面积0.912(P=0.001);以400 mm²/s为阈值诊断骨质疏松的敏感度90.90%、特异度83.34%、准确率88.89%、阳性预测值93.75%、阴性预测值76.93%。
要点
- 骨质疏松椎体ADC值显著低于正常椎体,ADC与BMD呈正相关(r=0.748)。
- 以ADC 400 mm²/s为阈值诊断骨质疏松,敏感度90.90%、特异度83.34%、准确率88.89%。
- DWI可对绝经后女性骨髓改变及骨质疏松进行定量评估。
核心结论
- 女性ADC值与BMD呈正相关,DWI可对绝经后女性骨髓改变及骨质疏松进行定量评估。
研究设计与样本
- 前瞻性研究,纳入60例绝经后女性(平均年龄60.2±6.11岁),对L2–L4共180个腰椎行DEXA与MRI检查。
- 依据DEXA骨密度测量将椎体分为正常组52个、骨量减少组92个、骨质疏松组36个。
- 对椎体行DWI检查评估表观扩散系数(ADC),比较三组ADC值并与BMD做相关性分析,采用ROC分析评估诊断效能。
关键影像表现/征象
- 骨质疏松组ADC值135.67±44.10×10⁻⁶ mm²/s显著低于正常组561.85±190.37×10⁻⁶ mm²/s(P=0.0001)。
诊断标准与关键数值
- ADC与BMD呈正相关(r=0.748,P=0.0001)。
- ROC分析中DWI的曲线下面积为0.912(P=0.001)。
- 以400 mm²/s为诊断骨质疏松的阈值,敏感度90.90%、特异度83.34%、准确率88.89%、阳性预测值93.75%、阴性预测值76.93%。
临床应用与阅片要点
- ADC值可与BMD联合用于绝经后女性椎体骨髓改变及骨质疏松的定量评估。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: In this study, we prospectively investigated the diagnostic capability of diffusion-weighted magnetic resonance imaging (DWI) in assessing vertebral marrow changes in postmenopausal women with osteoporosis.
MATERIALS AND METHODS: Sixty postmenopausal women (mean age 60.2 ± 6.11 years) underwent both dual-energy X-ray absorptiometry (DEXA) of the spine and MRI. Results were acquired from each patient's L2 to L4, for a total of 180 lumbar vertebrae. Based on bone mineral density (BMD) measurements obtained from DEXA, the vertebrae were divided into three groups as follows: normal (n = 52), osteopenic (n = 92), and osteoporotic (n = 36). DWI of the vertebral body was performed to assess the apparent diffusion coefficient (ADC). The ADC outcomes were compared among the three groups and correlated with BMD.
RESULTS: ADC values (× 10-6 mm2/s) were significantly lower in the osteoporotic group (135.67 ± 44.10) in comparison to the normal group (561.85 ± 190.37) (P = 0.0001). The results showed a positive correlation between ADC and BMD values (r = 0.748, P = 0.0001). In receiver operating characteristic (ROC) analysis, the area under the curve for DWI was 0.912 (P = 0.001). A cut-off value of 400 mm2/s for the diagnosis of osteoporosis; had sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of 90.90%, 83.34%, 88.89%, 93.75%, and 76.93%, respectively.
CONCLUSION: ADC values correlated positively with BMD in women. DWI can allow quantitative evaluation of bone marrow changes and osteoporosis in postmenopausal women.
引用
- Momeni M, Asadzadeh M, Mowla K, et al. Sensitivity and specificity assessment of DWI and ADC for the diagnosis of osteoporosis in postmenopausal patients. Radiol Med. 2019. PMID: 31531809. doi:10.1007/s11547-019-01080-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。