文献速递骨肌技术与安全USMR

一种新的简化综合性血友病关节超声方案:通用简化超声(US-US)方案

A new and simplified comprehensive ultrasound protocol of haemophilic joints: the Universal Simplified Ultrasound (US-US) protocol.
PubMed 文献 · Clin Radiol · 2019-08-29

研究对20个关节分别采用TVC-US、HEAD-US和新开发的US-US三种超声方案评估滑膜肥厚、含铁血黄素沉积、积液、骨侵蚀和软骨丢失,并以MRI为参考比较信度和诊断效能。US-US与TVC-US及MRI的一致性优于HEAD-US,且观察者间一致性良好。

要点

  • US-US方案评估滑膜肥厚与TVC-US一致性极佳(KS=1),HEAD-US仅为中等(KS=0.65)。
  • US-US评估骨侵蚀和软骨丢失与TVC-US及MRI一致性极佳(KS=1),HEAD-US较差(KS=0)。
  • US-US方案观察者间一致性良好(KS=1),可用于血友病关节病的超声评估。

核心结论

  • US-US方案的准确性与TVC-US方案及MRI相当,在评估血友病关节病方面优于HEAD-US方案。

研究设计与样本

  • 对20个血友病关节分别用TVC-US、HEAD-US和US-US三种超声方案评估,并以MRI为参考标准比较各方案的信度和诊断效能。

诊断标准与关键数值

  • 滑膜肥厚:TVC-US与US-US的kappa显著性(KS)为1,HEAD-US与US-US的KS为0.65。
  • 积液:TVC-US与US-US的KS为0.7,HEAD-US与US-US的KS为0.6。
  • 骨侵蚀和软骨丢失:TVC-US与US-US及MRI的KS为1,HEAD-US的KS为0。
  • US-US方案的观察者间一致性KS为1。

临床应用与阅片要点

  • US-US方案可用于血友病关节病的超声评估,其与TVC-US及MRI的一致性优于HEAD-US。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To present a new protocol to optimise ultrasound (US) assessment of haemophilic arthropathy.

MATERIALS AND METHODS: Ultrasound of haemophilic arthropathy joints was performed using three different ultrasound protocols, namely, the Toronto-Vellore Comprehensive Ultrasound (TVC-US) protocol, the Haemophilia Early Arthropathy Detection with Ultrasound (HEAD-US), and the newly developed Universal Simplified Ultrasound (US-US) protocol. Synovial hypertrophy, haemosiderin deposition, effusion, erosion, and cartilage loss were evaluated in 20 joints. The reliability and diagnostic efficiency of these protocols was compared using magnetic resonance imaging (MRI).

RESULTS: The correlation between the TVC-US and US-US protocols for synovial hypertrophy was excellent: kappa significance (KS) was 1, but was substantial (KS=0.65) with the HEAD-US protocol. For effusion, both the TVC-US and the HEAD-US protocols had substantial correlation with the US-US protocol (KS=0.7 and 0.6 respectively). The correlation for erosion and cartilage loss was excellent between the TVC-US and the US-US with MRI (KS=1), but poor (KS=0) with the HEAD-US protocol. The US-US protocol also had good interobserver agreement (KS=1).

CONCLUSION: The accuracy of the US-US protocol is comparable to the TVC-US protocol and MRI and is superior to the HEAD-US protocol in the assessment of haemophilic arthropathy.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Kandagaddala M, Sundaramoorthy M, Keshava SN, et al. A new and simplified comprehensive ultrasound protocol of haemophilic joints: the Universal Simplified Ultrasound (US-US) protocol. Clin Radiol. 2019. PMID: 31474302. doi:10.1016/j.crad.2019.07.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。