文献速递甲状腺与浅表US

超声引导下粗针穿刺活检技术用于中低度可疑甲状腺结节:哪种方法诊断更有效?

Ultrasound-Guided Core Needle Biopsy Techniques for Intermediate or Low Suspicion Thyroid Nodules: Which Method is Effective for Diagnosis?
PubMed 文献 · Korean J Radiol · 2019-01-01

该回顾性研究比较了两种超声引导下粗针穿刺活检技术对中低度可疑甲状腺结节的诊断效能,共纳入140个结节。第一种技术获取两份含结节组织、结节边缘及周围正常实质的标本(边缘靶向),第二种技术分别从边缘靶向和结节内靶向各取一份标本。第一种技术在预测肿瘤和恶性肿瘤的准确率及恶性肿瘤的阴性预测值上均显著高于第二种技术。

要点

  • 对中低度可疑甲状腺结节,两份标本均取边缘靶向的粗针穿刺活检诊断效能更高。
  • 边缘靶向技术预测肿瘤准确率100% vs 结节内+边缘靶向93.3%(p=0.032)。
  • 边缘靶向技术预测恶性肿瘤准确率88.8% vs 75.0%(p=0.033),阴性预测值87.5% vs 72.7%(p=0.035)。

核心结论

  • 对于中低度可疑甲状腺结节,超声引导下粗针穿刺活检获取两份边缘靶向标本在诊断肿瘤或恶性肿瘤方面比分别取边缘和结节内靶向标本更有效。

研究设计与样本

  • 回顾性研究,2015年8月至2016年12月连续对248个甲状腺结节交替应用两种活检技术,最终纳入140个中低度可疑甲状腺结节;第一种技术取两份含结节组织、结节边缘及周围正常实质的标本(边缘靶向),第二种技术取两份标本分别来自边缘靶向和结节内靶向;比较两种技术预测肿瘤和恶性肿瘤的诊断效能。

诊断标准与关键数值

  • 第一种技术(边缘靶向)预测肿瘤准确率100%,第二种技术(边缘+结节内靶向)93.3%(p=0.032);预测恶性肿瘤准确率第一种88.8% vs 第二种75.0%(p=0.033);预测恶性肿瘤阴性预测值第一种87.5% vs 第二种72.7%(p=0.035)。

临床应用与阅片要点

  • 在中低度可疑甲状腺结节进行超声引导下粗针穿刺活检时,采用两份标本均包含结节边缘及周围正常实质的取材方式可能提高诊断准确率。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To retrospectively compare the diagnostic performances of two different ultrasound (US)-guided core needle biopsy (CNB) techniques for intermediate or low suspicion thyroid nodules.

MATERIALS AND METHODS: Between August 2015 and December 2016, two different biopsy techniques were alternatively applied for 248 consecutive thyroid nodules, of which, 140 intermediate or low suspicion thyroid nodules were included in this study. In the first technique, two specimens included nodular tissue, nodular margin, and surrounding normal parenchyma (i.e., marginal target). In the second technique, two specimens were obtained from two different target areas, one for the marginal target and another for the intranodular target. The diagnostic performances of the two techniques to predict neoplasm and malignancy were compared.

RESULTS: CNB was performed on 80 intermediate or low suspicion nodules (57.1%) using the first technique and on 60 (42.9%) using the second technique. The accuracy of the first technique for predicting neoplasm or malignancy was significantly higher than that of the second technique (100% vs. 93.3%, p = 0.032 for predicting neoplasm; 88.8% vs. 75.0%, p = 0.033 for predicting malignancy). The negative predictive value of the first technique for predicting malignancy was also significantly higher than that of the second technique (87.5% vs. 72.7%, p = 0.035).

CONCLUSION: For intermediate or low suspicion thyroid nodules, US-guided CNB to obtain two specimens with marginal targets is more effective for diagnosing neoplasm or malignancy than is CNB for respective marginal and intranodular targets.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Hahn SY, Shin JH, Oh YL, et al. Ultrasound-Guided Core Needle Biopsy Techniques for Intermediate or Low Suspicion Thyroid Nodules: Which Method is Effective for Diagnosis? Korean J Radiol. 2019. PMID: 31544370. doi:10.3348/kjr.2018.0841

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。