乳腺X线摄影阅片者能否快速有效地学会解读首次增强后减影(FAST)MRI:一项单中心数据解读研究
研究评估NHS乳腺筛查项目的8名乳腺X线摄影阅片者(4名兼读乳腺MRI为第1组,4名不读为第2组)经中位4小时32分钟结构化培训后,前瞻性解读125例FAST MRI(250侧乳腺:194侧正常、56侧癌),共2000次判读。第2组准确率85%(95%CI 82-87%)较第1组90%(95%CI 88-92%)低5%;两组组内阅片者间一致性良好(第1组κ=0.66,95%CI 0.61-0.71;第2组κ=0.63,95%CI 0.58-0.68)。结论认为简短结构化培训可使多专业乳腺X线摄影阅片者达到与擅长乳腺MRI解读的顾问放射科医师相似的FAST MRI解读准确率。
要点
- FAST MRI判读采用NHSBSP MRI报告分类,4类和5类视为提示癌症。
- 第2组准确率85%(847/1000;95%CI 82-87%),第1组90%(898/1000;95%CI 88-92%),第2组低5%。
- 第1组阅片者间一致性κ=0.66(95%CI 0.61-0.71),第2组κ=0.63(95%CI 0.58-0.68)。
核心结论
- 简短结构化培训使多专业乳腺X线摄影阅片者解读FAST MRI的准确率与擅长乳腺MRI解读的顾问放射科医师相似。
- FAST MRI从培训劳动力角度看,在NHSBSP内用于筛查可能可行。
研究设计与样本
- 单中心数据解读研究,纳入8名NHSBSP乳腺X线摄影阅片者,其中4名兼读乳腺MRI(第1组)、4名不读(第2组)。
- 阅片者接受结构化FAST MRI阅片培训,中位4小时32分钟。
- 前瞻性解读125例FAST MRI(250侧乳腺:194侧正常、56侧癌),来自2015年连续筛查MRI序列并富集额外癌症病例,共产生2000次判读。
- 阅片者对其他阅片者意见和临床信息设盲;参考标准为组织学或2年随访。
诊断标准与关键数值
- 判读分类遵循NHSBSP MRI报告分类,4类和5类视为提示癌症。
- 第2组准确率85%(847/1000;95%CI 82-87%),较第1组90%(898/1000;95%CI 88-92%)低5%。
- 第1组阅片者间一致性κ=0.66(95%CI 0.61-0.71),第2组κ=0.63(95%CI 0.58-0.68)。
- 每例FAST MRI判读中位时间:第1组34秒(范围3-351秒),第2组77秒(范围11-321秒)。
临床应用与阅片要点
- NHSBSP乳腺X线摄影阅片者经简短结构化培训后可用于FAST MRI判读。
- 第2组判读准确率较第1组低5%,阅片者间一致性两组均为良好。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess whether NHS breast screening programme (NHSBSP) mammogram readers could effectively interpret first post-contrast acquisition subtracted (FAST) MRI, for intended use in screening for breast cancer.
METHODS: Eight NHSBSP mammogram readers from a single centre (four who also read breast MRI (Group 1) and four who do not (Group 2)) were given structured FAST MRI reader training (median 4 h: 32 min). They then prospectively interpreted 125 FAST MRIs (250 breasts: 194 normal and 56 cancer) comprising a consecutive series of screening MRIs enriched with additional cancer cases from 2015, providing 2000 interpretations. Readers were blinded to other readers' opinions and to clinical information. Categorisation followed the NHSBSP MRI reporting categorisation, with categories 4 and 5 considered indicative of cancer. Diagnostic accuracy (reference standard: histology or 2 years' follow-up) and agreement between readers were determined.
RESULTS: The accuracy achieved by Group 2 (847/1000 (85%; 95% confidence interval (CI) 82-87%)) was 5% less than that of Group 1 (898/1000 (90%; 95% CI 88-92)). Good inter-reader agreement was seen between both Group 1 readers (κ = 0.66; 95% CI 0.61-0.71) and Group 2 readers (κ = 0.63; 95% CI 0.58-0.68). The median time taken to interpret each FAST MRI was Group 1: 34 s (range 3-351) and Group 2: 77 s (range 11-321).
CONCLUSION: Brief structured training enabled multiprofessional mammogram readers to achieve similar accuracy at FAST MRI interpretation to consultant radiologists experienced at breast MRI interpretation.
ADVANCES IN KNOWLEDGE: FAST MRI could be feasible from a training-the-workforce perspective for screening within NHSBSP.
引用
- Jones LI, Geach R, Harding SA, et al. Can mammogram readers swiftly and effectively learn to interpret first post-contrast acquisition subtracted (FAST) MRI, a type of abbreviated breast MRI?: a single centre data-interpretation study. Br J Radiol. 2019. PMID: 31559859. doi:10.1259/bjr.20190663
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。