文献速递乳腺乳腺X线

乳腺肿块大小测量比较:合成乳腺X线摄影与全视野数字乳腺X线摄影

Comparison of Mass Size Measurements: Synthesized Mammography Versus Full-Field Digital Mammography.
PubMed 文献 · Acad Radiol · 2019-09-16

研究纳入143例同期接受全视野数字乳腺X线摄影(FFDM)和数字乳腺断层摄影的患者的合成乳腺X线摄影(SM)图像,由两名观察者独立测量肿块最大径。结果显示SM图像上测得的肿块尺寸显著小于FFDM图像,且两种成像技术间的观察者间差异大于FFDM与SM之间的差异。

要点

  • SM图像上测得的乳腺肿块最大径显著小于FFDM图像(p < 0.001)。
  • 两种技术间的观察者间测量差异大于FFDM与SM之间的测量差异。
  • 阅片时需注意SM可能低估肿块大小,报告时应结合FFDM图像综合评估。

核心结论

  • SM图像上测得的肿块尺寸显著小于FFDM图像,且两种成像技术的观察者间差异均大于FFDM与SM之间的差异。

研究设计与样本

  • 研究纳入143例在同一压迫时段内接受FFDM和数字乳腺断层摄影采集的患者,由两名分别具有4年和1年数字乳腺断层摄影及SM图像经验的观察者独立测量肿块大小;两次测量间隔2周,分别仅评估FFDM图像和仅评估SM图像,观察者彼此盲法;测量肿块最大径(毫米);采用配对t检验比较FFDM与SM的尺寸测量差异,组内相关系数分析观察者间一致性,Bland-Altman分析评估成像技术间及观察者间的一致性。

诊断标准与关键数值

  • 观察者1在FFDM和SM图像上的平均肿块大小分别为20.27 ± 14.10 mm和18.50 ± 13.05 mm。
  • 观察者2在FFDM和SM图像上的平均肿块大小分别为21.56 ± 14.84 mm和19.89 ± 13.68 mm。
  • 两名观察者中FFDM与SM的肿块尺寸测量差异均具有统计学意义(p < 0.001)。
  • 观察者1和观察者2在两种成像技术间的测量误差范围(定义为95%一致性界限)分别为±1.96*1.36 mm和±1.96*1.53 mm。
  • 观察者间在SM和FFDM上的测量误差范围(定义为95%一致性界限)分别为±1.96*3.68 mm和±1.96*3.35 mm。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare mass size measurements between synthesized mammography (SM) and full-field digital mammography (FFDM), and to assess interobserver agreement for those measurements.

MATERIALS AND METHODS: One hundred and forty-three patients who underwent FFDM and digital breast tomosynthesis acquisitions during the same compression session were included in the study. Two observers with four-and 1-year experience with digital breast tomosynthesis and SM images, respectively, measured mass sizes independently in two different sessions that were 2 weeks apart, and were blinded to each other. The first session included only FFDM images, and the second session included only SM images. Largest dimension of masses was measured in millimeters. Paired t test was used to compare differences in size measurements between FFDM and SM images. Intraclass correlation coefficient test was used to analyze interobserver agreement. Bland-Altman analyses were performed to evaluate agreements between the imaging techniques and between the observers.

RESULTS: The mean mass sizes on FFDM and SM images were 20.27 ± 14.10 and 18.50 ± 13.05 mm, respectively, for the first observer and 21.56 ± 14.84 and 19.89 ± 13.68 mm, respectively, for the second observer. The mass size measurements were significantly different between FFDM and SM for both observers (p < 0.001). Range of measurement errors, defined as 95% limits of agreements between two imaging techniques for observers 1 and 2 were ±1.96*1.36 mm, and ±1.96*1.53 mm, respectively. Range of measurement errors, defined as 95% limits of agreements between two observers for SM and FFDM were ±1.96*3.68 mm, and ±1.96*3.35 mm, respectively.

CONCLUSION: The measured mass sizes were significantly smaller on SM than FFDM images, and the interobserver differences for both of the imaging techniques were greater than the differences measured between FFDM and SM images.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Şendur HN, Cerit MN, Gültekin S, et al. Comparison of Mass Size Measurements: Synthesized Mammography Versus Full-Field Digital Mammography. Acad Radiol. 2019. PMID: 31537507. doi:10.1016/j.acra.2019.08.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。