采用多压缩策略与全乳腺扫描系统的大应变三维在体乳腺超声弹性成像

Large-Strain 3-D in Vivo Breast Ultrasound Strain Elastography Using a Multi-compression Strategy and a Whole-Breast Scanning System.
PubMed 文献 · Ultrasound Med Biol · 2019-09-21

本研究提出多压缩策略产生大组织变形,并用三维区域生长运动追踪法估计大变形下组织三维运动,先估计逐体积增量位移、剔除离群值后配准累积位移。用一套在体荷瘤乳腺超声数据测试,共10个小应变变形步骤,病灶及周围分别变形约6%和16%,所提方法弹性图CNR和SNR均高于二维追踪法,三个正交视图累积轴向应变图上病灶清晰可见且与B模式图像对应良好。

要点

  • 多压缩策略可产生大于10%的大组织变形,用于获取乳腺组织非线性力学特性。
  • 所提三维追踪法先估计增量位移、剔除离群值再配准累积,避免误差累积。
  • 所提方法弹性图CNR和SNR均高于二维追踪法,累积轴向应变图与B模式对应良好。

核心结论

  • 所提多压缩策略与三维运动估计方法可在体获得大变形下乳腺组织的累积位移场和轴向应变图。
  • 所提方法所得弹性图CNR和SNR均高于二维追踪方法。
  • 在三个正交视图的累积轴向应变图上,乳腺病灶清晰可见,且轴向应变与B模式图像对应良好。

研究设计与样本

  • 本研究为方法学研究,提出多压缩策略和三维区域生长运动追踪方法,并用一套在体荷瘤乳腺超声数据测试。
  • 数据来自一名人类受试者的一套在体荷瘤乳腺超声数据。
  • 共进行10个小应变变形步骤以获得最终累积位移场。
  • 比较对象为所提方法与二维追踪方法。

关键影像表现/征象

  • 在最终累积位移场中,乳腺病灶及其周围组织分别变形约6%和16%。
  • 三个正交视图的累积轴向应变图上乳腺病灶清晰可见。
  • 轴向应变图与B模式图像对应良好。

诊断标准与关键数值

  • 所提方法弹性图的CNR和SNR均高于二维追踪方法所得。
  • 大组织变形示例为大于10%。

局限性

  • 所提方法仅用一套在体荷瘤乳腺超声数据进行了测试。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Non-linear mechanical properties of breast tissue can be employed to diagnose and differentiate breast tumors. To obtain such non-linear mechanical properties, it is necessary to track tissue motion under large deformation. In this study, a multi-compression strategy was utilized to produce large tissue deformation, and a method to estimate 3-D motion of tissue under large deformation was introduced. Given multiple volumes of ultrasound data, the proposed method first estimates volume-to-volume incremental displacements using a 3-D region-growing motion-tracking method. Then, possible outliers among all incremental displacements are removed to avoid error accumulation. Once large displacement errors have been removed, all incremental displacements are registered together to obtain accumulated displacements under large tissue deformation (e.g., >10%). The proposed method was tested with one set of in vivo tumor-bearing ultrasound data acquired from a human subject. A total of 10 small-strain deformation steps were performed to obtain the final accumulated displacement field, in which the breast lesion and its surrounding were deformed by approximately 6% and 16%, respectively. The contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) of the elasticity images obtained with the proposed method were all higher than those obtained with a 2-D tracking method. Furthermore, in three orthogonal views of accumulated axial strain images, the breast lesion was clearly visible with good correspondence between the axial strain and B-mode images.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Wang Y, Bayer M, Jiang J, et al. Large-Strain 3-D in Vivo Breast Ultrasound Strain Elastography Using a Multi-compression Strategy and a Whole-Breast Scanning System. Ultrasound Med Biol. 2019. PMID: 31548103. doi:10.1016/j.ultrasmedbio.2019.08.013