锥光束乳腺CT与数字乳腺X线摄影舒适度比较

Comparison of comfort between cone beam breast computed tomography and digital mammography.
PubMed 文献 · Eur J Radiol · 2019-09-16

对409例患者在常规乳腺X线摄影后1周内行锥光束乳腺CT(CBBCT),用11点数字评分量表(NRS-11)评价舒适度(分值越低越舒适)。总体上CBBCT舒适度优于乳腺X线摄影(P<0.05),在非增强和增强扫描、≤44岁和45∼59岁年龄组、BMI 18.5∼23.9、24∼27.9和≥28 kg/m2组及脂肪型和致密型乳腺组中均更舒适(P<0.05);≥60岁组(P=0.5433)和BMI<18.5 kg/m2组(P=0.43)无显著差异。

要点

  • 总体上CBBCT舒适度优于数字乳腺X线摄影(P<0.05),NRS-11分值越低越舒适。
  • ≥60岁组(P=0.5433)和BMI<18.5 kg/m2组(P=0.43)两种检查舒适度无显著差异。
  • 非增强与增强CBBCT、≤44岁和45∼59岁组、BMI 18.5∼23.9/24∼27.9/≥28 kg/m2组及脂肪型和致密型乳腺组中CBBCT均更舒适(P<0.05)。

核心结论

  • CBBCT的舒适度优于数字乳腺X线摄影。

研究设计与样本

  • 对409例患者在常规乳腺X线摄影后1周内行CBBCT,检查完成后患者用11点数字评分量表(NRS-11)评价舒适度。

诊断标准与关键数值

  • 舒适度采用11点数字评分量表(NRS-11)评价,分值越低表示检查越舒适;按CBBCT扫描模式(非增强、增强)、年龄(≤44、45∼59、≥60岁)、BMI(<18.5、18.5∼23.9、24∼27.9、≥28 kg/m2)和乳腺密度(脂肪型、致密型)分组比较。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare the comfort levels of cone beam breast computed tomography (CBBCT) and digital mammography.

MATERIALS AND METHODS: On 409 patients, CBBCT was performed within 1 week after conventional mammography. Patients evaluated their comfort by using an 11-point numerical rating scale (NRS-11) after completing the two examinations. The lower the score was, the more comfortable the examination modality was. The data was divided into different groups according to CBBCT scan mode (non-contrast mode, contrast-enhanced mode), age (≤44, 45∼59 and ≥60), body mass index (BMI) (<18.5 kg/m2, 18.5∼23.9 kg/m2, 24∼27.9 kg/m2 and ≥28 kg/m2), and breast density (fatty-breast, dense-breast) to evaluate the performance of CBBCT comfort in different groups and to analyse the influencing factor of patient comfort. The paired rank sum test was used to compare the comfort between CBBCT and mammography.

RESULTS: Overall, the comfort of CBBCT was better than mammography (P < 0.05). CBBCT was more comfortable than mammography in both non-contrast and contrast-enhanced groups (P < 0.05). CBBCT was more comfortable than mammography in the ≤44, 45∼59 age groups (P < 0.05). There was no significant difference in the ≥60 age group (P = 0.5433). CBBCT was more comfortable than mammography in the BMI groups of 18.5∼23.9 kg/m2, 24∼27.9 kg/m2and ≥28 kg/m2 (P < 0.05). There was no significant difference in the <18.5 kg/m2 group (P = 0.43). CBBCT was more comfortable than mammography in both the fatty-breast and dense-breast groups (P < 0.05).

CONCLUSION: The comfort of CBBCT was better than mammography.

来源:Eur J Radiol,查看原文。版权归原作者所有。