文献速递乳腺乳腺X线

立体定向9G真空辅助乳腺活检需要多少份标本

Stereotactic 9-gauge vacuum-assisted breast biopsy, how many specimens are needed?
PubMed 文献 · Eur J Radiol · 2019-09-14

这项前瞻性单中心观察性队列研究纳入120例女性的129个乳腺可疑病灶,行立体定向9G真空辅助活检,每病灶取12份标本。95%(95%CI 90%-98%)的操作在6份标本后获得最终组织病理诊断,9份标本后全部131例操作均确立诊断。作者结论认为取9份标本似乎最佳,一旦取到钙化就终止操作可能导致假阴性。

要点

  • 6份立体定向9G真空辅助活检标本可在95%(95%CI 90%-98%)的操作中确立最终组织病理诊断。
  • 取9份9G标本后全部131例操作均确立最终活检诊断,作者认为取9份似乎最佳。
  • 在41例活检诊断为DCIS或浸润性病变的患者中,有8例操作(20%)在获得诊断性标本之前就已取到钙化。

核心结论

  • 6份立体定向9G真空辅助活检标本可在95%(95%CI 90%-98%)的操作中确立最终组织病理活检诊断;取9份9G标本似乎最佳;一旦取到钙化即终止立体定向真空辅助乳腺活检操作可能导致假阴性结果。

研究设计与样本

  • 前瞻性单中心观察性队列研究,2017年12月至2018年10月纳入120例女性的129个乳腺X线可疑病灶,行立体定向9G真空辅助活检,每病灶获取12份标本,对每份标本单独行X线摄影评估钙化取材情况,并按时间顺序逐一组织学分析,与全部12份标本评估后的最终组织病理结果及手术切除结果比较。

诊断标准与关键数值

  • 在95%(95%CI 90%-98%)的操作中,6份标本后达到最终组织病理活检诊断。
  • 9份标本后全部131例操作均确立最终活检诊断。
  • 41例活检诊断为DCIS或浸润性病变的患者中,8例操作(20%)在获得诊断性标本之前已取到钙化。
  • 30个活检分类为DCIS并切除的病灶中6个(20%)低估了后续切除诊断,4个切除的高危病灶中1个低估。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To determine the minimum number of stereotactic 9-gauge vacuum-assisted biopsy specimens required to establish a final histopathological biopsy diagnosis of mammographically suspicious breast lesions.

METHODS: This prospective single-center observational cohort study included 120 women referred for stereotactic vacuum-assisted biopsy of 129 mammographically suspicious lesions between December 2017 and October 2018. Stereotactic 9-gauge vacuum-assisted biopsy was performed, acquiring twelve specimens per lesion. Calcification retrieval was assessed with individual specimen radiography. Each specimen was histologically analyzed in chronological order and findings were compared with the final histopathological result after assessment of all twelve specimens and with results of surgical excision. Cumulative diagnostic yield per specimen was calculated.

RESULTS: In total, 131 biopsy procedures were performed in 120 women (mean age 59 years). In 95% (95%CI 90%-98%) of the procedures a final histopathological diagnosis was reached after six specimens. After nine specimens the final biopsy diagnosis was established in all 131 cases. In the subgroup of 41 patients with a DCIS or invasive diagnosis at biopsy there were eight procedures (20%) where calcifications were retrieved before the diagnostic specimen was obtained. Underestimation of subsequent resection diagnosis occurred in six out of 30 excised lesions classified as DCIS (20%) and in one out of four excised high-risk lesions.

CONCLUSIONS: With six stereotactic 9-gauge vacuum-assisted biopsy specimens a final histopathological biopsy diagnosis could be established in 95% (95%CI 90%-98%) of the biopsy procedures. Taking nine 9-gauge specimens seems to be optimal. Ending the stereotactic vacuum-assisted breast biopsy procedure as soon as calcifications are retrieved may cause false negative results.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. den Dekker BM, van Diest PJ, de Waard SN, et al. Stereotactic 9-gauge vacuum-assisted breast biopsy, how many specimens are needed? Eur J Radiol. 2019. PMID: 31563108. doi:10.1016/j.ejrad.2019.108665

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。