文献速递妇产影像泌尿生殖MR

全实性肿瘤体积的表观扩散系数直方图分析鉴别高级别与低级别浆液性卵巢癌:与Ki-67增殖状态的相关性

Whole solid tumour volume histogram analysis of the apparent diffusion coefficient for differentiating high-grade from low-grade serous ovarian carcinoma: correlation with Ki-67 proliferation status.
PubMed 文献 · Clin Radiol · 2019-08-27

回顾性分析107例高级别浆液性卵巢癌(HGSOC)与19例低级别浆液性卵巢癌(LGSOC)患者的MRI及DWI资料,基于全实性肿瘤体积ROI提取ADC直方图参数。HGSOC的ADC均值、标准差及第10至90百分位数均显著低于LGSOC,偏度显著高于LGSOC,峰度无显著差异;除峰度外各参数与Ki-67指数相关性弱。ADC直方图参数有助于鉴别HGSOC与LGSOC。

要点

  • 基于全实性肿瘤体积ROI的ADC直方图参数有助于鉴别HGSOC与LGSOC,其中ADC均值、标准差及第10至90百分位数在HGSOC中显著降低。
  • 偏度在HGSOC中显著高于LGSOC(p<0.001,AUC=0.773),峰度在两组间无显著差异(p=0.140)。
  • 除峰度外,各直方图参数与Ki-67增殖指数相关性弱(|r|=0.191-0.274,p<0.05)。

核心结论

  • 基于全实性肿瘤体积的ADC直方图参数有助于鉴别高级别与低级别浆液性卵巢癌。

研究设计与样本

  • 回顾性分析经手术和组织学证实的107例HGSOC与19例LGSOC患者,均行常规MRI和DWI检查,采用全实性肿瘤体积ROI提取ADC直方图参数。

诊断标准与关键数值

  • HGSOC较LGSOC的ADC均值(p<0.001)、标准差(p=0.003)及第10、25、50、75、90百分位数(均p<0.001)显著降低,AUC为0.717-0.807;偏度在HGSOC显著升高(p<0.001,AUC=0.773);峰度无显著差异(p=0.140)。

临床应用与阅片要点

  • 阅片时可基于全实性肿瘤体积ROI提取ADC直方图参数,其中均值、标准差及第10至90百分位数在HGSOC中降低、偏度升高,有助于鉴别HGSOC与LGSOC。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To investigate whether apparent diffusion coefficient (ADC) histogram parameters based on whole solid tumour volume could differentiate high-grade (HGSOC) from low-grade serous ovarian carcinoma (LGSOC) and to correlate those parameters with the Ki-67 proliferation index.

MATERIALS AND METHODS: One hundred and seven patients with HGSOCs and 19 patients with LGSOCs confirmed at surgery and histology who underwent conventional magnetic resonance imaging (MRI) and diffusion-weighted imaging (DWI) were analysed retrospectively. ADC histogram parameters (including the mean, standard deviation [SD], 10th, 25th, 50th, 75th, and 90th percentiles, kurtosis, and skewness) were obtained using the whole solid tumour volume region of interest (ROI). The Mann-Whitney U test, Pearson's chi-square test, Fisher's exact test, kappa test, Spearman's correlation, and receiver operating characteristic (ROC) curves were used for statistical analyses.

RESULTS: For ADC histogram parameters, the mean (p<0.001), SD (p=0.003), and all percentiles (10th, 25th, 50th, 75th, and 90th percentile; all p<0.001) were significantly lower in HGSOC than in LGSOC, and the area under the ROC curve (AUC) was 0.717-0.807. Skewness was significantly higher in HGSOC than in LGSOC (p<0.001, AUC = 0.773); however, kurtosis was not significantly different between HGSOC and LGSOC (p=0.140). The 25th and 75th percentiles, SD and 10th percentile, and 75th percentile showed the highest sensitivity of 91.6%, specificity of 79.0%, and accuracy of 88.1%, respectively. All histogram parameters (except for kurtosis) were poorly correlated with the Ki-67 index (|r| = 0.191-0.274, p<0.05).

CONCLUSION: ADC histogram parameters based on whole solid tumour volume can be helpful for differentiating between HGSOC and LGSOC.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Li HM, Zhang R, Gu WY, et al. Whole solid tumour volume histogram analysis of the apparent diffusion coefficient for differentiating high-grade from low-grade serous ovarian carcinoma: correlation with Ki-67 proliferation status. Clin Radiol. 2019. PMID: 31471063. doi:10.1016/j.crad.2019.07.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。