文献速递腹部妇产影像CT

计算机断层扫描诊断肠道子宫内膜异位症的诊断效能:一项系统评价与荟萃分析

Diagnostic performance of computed tomography for bowel endometriosis: A systematic review and meta-analysis.
PubMed 文献 · Eur J Radiol · 2019-08-11

该系统评价与荟萃分析检索PubMed和EMBASE至2019年3月28日,纳入12项研究共1091例患者,以腹腔镜后组织病理学为参考标准,评估CT诊断肠道子宫内膜异位症的效能。汇总敏感度为0.92(95%CI 0.83-0.97),特异度为0.95(95%CI 0.88-0.98),存在显著异质性(敏感度I²=92.38%,特异度I²=89.09%)和发表偏倚(P=0.04)。有子宫内膜异位症手术史的患者研究特异度显著高于无此病史者(0.95 vs 0.75)。

要点

  • CT诊断肠道子宫内膜异位症汇总敏感度0.92、特异度0.95,但异质性高(I²>89%)。
  • 有子宫内膜异位症手术史者研究特异度0.95,显著高于无手术史者的0.75。
  • Deeks不对称检验提示发表偏倚(P=0.04),纳入研究数量少,结论需进一步验证。

核心结论

  • CT诊断肠道子宫内膜异位症表现出色,但纳入研究数量少且存在发表偏倚,可能需要进一步研究验证这些结果。

研究设计与样本

  • 系统评价与荟萃分析,检索PubMed和EMBASE至2019年3月28日,纳入12项以腹腔镜后组织病理学为参考标准的CT诊断准确性研究,共1091例患者,采用QUADAS-2评估方法学质量,采用双变量层次汇总受试者工作特征模型汇总敏感度和特异度,并行Meta回归探索异质性。

诊断标准与关键数值

  • 汇总敏感度0.92(95%CI 0.83-0.97),汇总特异度0.95(95%CI 0.88-0.98);有子宫内膜异位症手术史者研究特异度0.95(95%CI 0.91-1.00),无此病史者研究特异度0.75(95%CI 0.43-1.00)。

临床应用与阅片要点

  • 作者认为CT在肠道子宫内膜异位症诊断中表现出色,但指出因纳入研究数量少和发表偏倚,可能需要进一步研究验证结果。

局限性

  • 异质性显著:敏感度I²=92.38%,特异度I²=89.09%。
  • Deeks不对称检验提示发表偏倚(P=0.04)。
  • 纳入研究数量少,可能需要进一步研究验证结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To perform a systematic review and meta-analysis regarding the performance of CT for diagnosis of bowel endometriosis.

MATERIALS AND METHODS: Pubmed and EMBASE were systematically searched up to March 28, 2019. Diagnostic accuracy studies using CT for diagnosis of bowel endometriosis using laparoscopy followed by histopathology as the reference standard were included. Methodological quality of the included studies was evaluated using Quality Assessment of Diagnostic Accuracy Studies-2. Sensitivity and specificity were pooled using hierarchical summary receiver operating modelling. Meta-regression analysis was done to explore heterogeneity.

RESULTS: Twelve studies (1091 patients) were included. Pooled sensitivity and specificity were 0.92 (95% confidence interval [CI], 0.83-0.97) and 0.95 (95% CI, 0.88-0.98), respectively. Substantial heterogeneity was present: I2 = 92.38% for sensitivity and 89.09% for specificity. Deeks' asymmetry test suggested publication bias (p = 0.04). At meta-regression analysis, history of prior surgery for endometriosis was the only significant factor affecting heterogeneity (p < 0.01). Specifically, studies that included patients with such history demonstrated significantly greater specificity than studies that did not (0.95 [95% CI, 0.91-1.00] vs 0.75 [95% CI, 0.43-1.00]).

CONCLUSIONS: CT shows excellent performance in the diagnosis of bowel endometriosis. Due to small number of included studies and publication bias, further studies may be needed to validate these results.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Woo S, Suh CH, Kim H, et al. Diagnostic performance of computed tomography for bowel endometriosis: A systematic review and meta-analysis. Eur J Radiol. 2019. PMID: 31493726. doi:10.1016/j.ejrad.2019.08.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。