文献速递妇产影像腹部MR

常规DWI能否准确评估子宫内膜癌的大小

Can conventional DWI accurately assess the size of endometrial cancer?
PubMed 文献 · Abdom Radiol (NY) · 2020-01-01

本研究纳入34例子宫内膜癌患者,比较T2WI与常规DWI在定性诊断敏感度及肿瘤大小测量准确性的差异。T2WI-DWI定性诊断敏感度97%高于单独T2WI的85%(p=0.046);T2WI测量肿瘤大小与大体手术标本无显著差异,而cDWI测量值偏小(P=0.002),在G2/3级及最大径≥3cm病灶中cDWI准确性显著下降。

要点

  • T2WI-DWI联合定性诊断子宫内膜癌敏感度97%,高于单独T2WI的85%(p=0.046)。
  • T2WI测量肿瘤长径和横径与大体手术标本无显著差异,cDWI测量值偏小(P=0.002)。
  • G2/3级或最大径≥3cm的病灶,cDWI测值准确性显著下降,T2WI仍与标本一致。

核心结论

  • cDWI可高敏感度检出子宫内膜癌,但对G2/3级及大病灶测值偏小,T2WI测值与所有病灶实际大小一致,肿瘤异质性可能是cDWI测值不准的原因。

研究设计与样本

  • 纳入34例子宫内膜癌患者,均行根治性子宫切除术并于术前接受MRI检查,以术后病理为参考标准,比较T2WI与cDWI定性诊断敏感度及肿瘤大小测量值与大体积手术标本的差异。

关键影像表现/征象

  • 子宫内膜癌不同区域ADC值表现为从肿瘤中央区向外周区ADC均值逐渐升高、ADC范围逐渐增宽。

诊断标准与关键数值

  • 定性诊断敏感度:T2WI-DWI联合97% vs 单独T2WI 85%(p=0.046)。
  • 全部病灶肿瘤大小:T2WI长径3.90 cm、横径2.88 cm vs 大体标本长径4.00 cm、横径3.06 cm(PLD=0.579;PHD=0.261);cDWI长径3.01 cm、横径2.54 cm vs 大体标本(PLD=0.002;PHD=0.002)。
  • G1级或最大径<3 cm亚组:T2WI与cDWI测值均与大体标本无显著差异。
  • G2+3级或最大径≥3 cm亚组:T2WI仍与大体标本一致,cDWI准确性显著下降。

临床应用与阅片要点

  • 阅片测量子宫内膜癌肿瘤大小时,T2WI测值与大体标本一致,cDWI在G2/3级及最大径≥3 cm病灶中测值偏小。
  • 定性诊断可结合T2WI与DWI,联合敏感度高于单独T2WI。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare T2-weighted image (T2WI) and conventional Diffusion-weighted image (cDWI) of magnetic resonance imaging (MRI) for sensitivity of qualitative diagnosis and accuracy of tumor size (TS) measurement in endometrial cancer (EC). Meanwhile, the effect of the lesion size itself and tumor grade on the ability of T2WI and cDWI of TS assessment was explored. Ultimately, the reason of deviation on size evaluation was studied.

MATERIALS AND METHODS: 34 patients with EC were enrolled. They were all treated with radical hysterectomy and performed MR examinations before operation. Firstly, the sensitivity of T2WI alone and T2WI-DWI in qualitative diagnosis of EC were compared according to pathology. Secondly, TS on T2WI and cDWI described with longitudinal (LD) and horizontal diameter (HD) were compared to macroscopic surgical specimen (MSS) quantitatively in the entire lesions and the subgroup lesions which grouped by postoperative tumor size itself and tumor grade. Thirdly, the discrepancy of mean ADC values (ADC mean) and range ADC values (ADC range) between different zones of EC were explored.

RESULTS: For qualitative diagnosis, the sensitivity of T2WI-DWI (97%) was higher than T2WI alone (85%) (p = 0.046).For TS estimation, no significant difference (PLD = 0.579; PHD = 0.261) was observed between T2WI (LDT2WI = 3.90 cm; HDT2WI = 2.88 cm) and MSS (LD = 4.00 cm; HD = 3.06 cm), whereas TS of cDWI (LDDWI = 3.01 cm; HDDWI = 2.54 cm) were smaller than MSS (PLD = 0.002; PHD = 0.002) in all lesions. In subgroup of tumor with G1 (grade 1) and small lesion (defined as maximum diameter < 3 cm), both T2WI and cDWI were not significantly different from MSS; In subgroup of tumor with G2 + 3 (grade 2 and grade 3) and big lesion (maximum diameter ≥ 3 cm), T2WI matched well with MSS still, but DWI lost accuracy significantly. The result of ADC values between different zones of tumor showed ADC mean of EC rose from central zone to peripheral zone of tumor gradually and ADC range widened gradually.

CONCLUSION: cDWI can detect EC very sensitively. The TS on cDWI was smaller than the fact for the ECs with G2/3 and big size. The TS of T2WI was in accordance with the actual size for all ECs. The heterogeneity may be responsible for the inaccuracy of cDWI.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Song Y, Shang H, Ma Y, et al. Can conventional DWI accurately assess the size of endometrial cancer? Abdom Radiol (NY). 2020. PMID: 31511958. doi:10.1007/s00261-019-02220-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。