酰胺质子转移成像鉴别良性卵巢囊性病变:首次即正确的潜力
这项前瞻性研究纳入18例患者的19个良性卵巢囊性病变(浆液性囊腺瘤4个、黏液性囊腺瘤9个、功能性囊肿6个),采用0.5、1.0、2.0秒三种预饱和脉冲时长行酰胺质子转移成像,并以囊液与肌肉信号强度比值及表观扩散系数作对比。2.0秒预饱和时三组APT信号分别为1.41±0.71%、5.15±1.92%和8.52±1.17%,两两间均有显著差异;ADC仅浆液性与黏液性囊腺瘤间有差异,T1、T2比值三组间无显著差异。作者认为APT成像可能有助于良性卵巢囊性病变的无创诊断。
要点
- 2.0秒预饱和时APT信号在浆液性囊腺瘤、黏液性囊腺瘤与功能性囊肿间两两均有显著差异。
- ADC仅浆液性囊腺瘤与黏液性囊腺瘤间有显著差异,T1、T2比值三组间无显著差异。
- 作者认为APT成像可能有助于良性卵巢囊性病变的无创诊断,较长预饱和脉冲可能提供早期正确诊断。
核心结论
- APT成像可能有助于良性卵巢囊性病变的无创诊断。
- 使用尽可能长的预饱和脉冲时,APT成像可能无需额外随访检查即可对卵巢囊性病变做出早期且正确的诊断。
研究设计与样本
- 前瞻性研究,共纳入18例患者的19个良性卵巢囊性病变:浆液性囊腺瘤4个、黏液性囊腺瘤9个、功能性囊肿6个。
- APT成像采用0.5、1.0和2.0秒三种预饱和脉冲时长,APT信号定义为3.5 ppm处的磁化传递率不对称。
- 以T1、T2加权图像上囊液与肌肉信号强度比值定义T1比值与T2比值,并生成表观扩散系数图。
关键影像表现/征象
- 2.0秒预饱和时APT信号:浆液性囊腺瘤1.41±0.71%、黏液性囊腺瘤5.15±1.92%、功能性囊肿8.52±1.17%。
- APT信号在浆液性囊腺瘤与黏液性囊腺瘤间p<.01、黏液性囊腺瘤与功能性囊肿间p<.05、浆液性囊腺瘤与功能性囊肿间P<.0001均有显著差异。
- 1.0秒预饱和脉冲时获得相似结果。
- ADC值仅在浆液性囊腺瘤(2.91±0.03×10-3 mm2/s)与黏液性囊腺瘤(2.59±0.49×10-3 mm2/s)间有显著差异(p<.05)。
- T1比值与T2比值在三组间均无显著差异。
诊断标准与关键数值
- 2.0秒预饱和时APT信号在浆液性囊腺瘤、黏液性囊腺瘤与功能性囊肿之间两两均有显著差异。
- ADC值仅浆液性囊腺瘤与黏液性囊腺瘤间有显著差异(p<.05)。
- T1比值与T2比值在三组间无显著差异。
临床应用与阅片要点
- 作者认为APT成像可能有助于良性卵巢囊性病变的无创诊断。
- 作者认为使用尽可能长的预饱和脉冲时,APT成像可能无需额外随访检查即可对卵巢囊性病变做出早期且正确的诊断。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To investigate whether amide proton transfer (APT) imaging is useful to differentiate benign ovarian cystic lesions.
MATERIALS AND METHODS: This prospective study enrolled a total of 19 lesions in 18 patients with benign ovarian cystic lesion: serous cystadenoma (SCA), n = 4; mucinous cystadenoma (MCA), n = 9; or functional cyst (FC), n = 6. APT imaging was performed with three different presaturation pulse durations: 0.5, 1.0 and 2.0 s. APT signal was defined as magnetization transfer ratio asymmetry at 3.5 ppm. The SI ratios of cyst to muscle calculated on T1- and T2-weighted images were defined as T1- and T2-ratios. Apparent diffusion coefficient (ADC) maps were also generated. We compared the three cystic lesion groups' APT signals, T1-ratio, T2-ratio, and ADC.
RESULTS: When using 2.0 s of presaturation, the APT signals were 1.41 ± 0.71% in SCA, 5.15 ± 1.92% in MCA and 8.52 ± 1.17% in FC. Significant differences were observed between SCA and MCA (p < .01) and MCA and FC (p < .05), as well as between SCA and FC (P < .0001). When 1.0 s presaturation pulse was used, similar results were obtained. On the other hand, ADC value shows significance only between SCA (2.91±0.03×10-3 mm2/s) and MCA (2.59 ± 0.49 × 10-3 mm2/s, p < .05). Further, there was no significant difference in the T1-ratio, T2-ratio among the three groups.
CONCLUSIONS: APT imaging might be useful for the non-invasive diagnosis of benign ovarian cystic lesions. With the use of the longer presaturation pulse as possible, APT imaging may provide an early and correct diagnosis of ovarian cystic lesions without additional follow-up studies.
引用
- Ishimatsu K, Nishie A, Takayama Y, et al. Amide proton transfer imaging for differentiating benign ovarian cystic lesions: Potential of first time right. Eur J Radiol. 2019. PMID: 31541877. doi:10.1016/j.ejrad.2019.108656
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。