文献速递腹部外周血管泌尿生殖CT

使用ASiR-V的低剂量CT血管造影用于潜在活体肾供者:图像质量与诊断准确性的前瞻性分析

Low-dose CT angiography using ASiR-V for potential living renal donors: a prospective analysis of image quality and diagnostic accuracy.
PubMed 文献 · Eur Radiol · 2019-08-30

这项前瞻性研究纳入80例潜在活体肾供者,随机采用ASiR-V低剂量或标准方案多期CT血管造影评估肾血管解剖,以手术为参考标准。低剂量CT的体型特异性剂量估计为9.5±0.8 mGy,显著低于标准CT的22.7±4.1 mGy(p<0.001),辐射剂量降低58.2%;低剂量CT的CNR和SNR均显著高于标准CT(p<0.001),定性图像质量相似(p>0.05);两种方法均能准确预测肾血管解剖。

要点

  • 低剂量CT血管造影的体型特异性剂量估计为9.5±0.8 mGy,标准CT血管造影为22.7±4.1 mGy,低剂量方案辐射剂量降低58.2%(p<0.001)。
  • 低剂量CT的CNR和SNR均显著高于标准CT(p<0.001),定性图像质量两者相似(p>0.05)。
  • 低剂量CT对肾血管数目或早期分支血管的准确率为96.6%,对左侧腰升静脉引流入左肾静脉的准确率为85.7%,与标准CT的100%相比均无显著差异(p>0.05)。

核心结论

  • 使用ASiR-V的低剂量CT血管造影可用于评估潜在活体肾供者的肾血管解剖。

研究设计与样本

  • 前瞻性研究,100例潜在活体肾供者中80例入组,随机采用ASiR-V低剂量或标准方案行多期CT血管造影(平扫、动脉期、静脉期),以手术确认作为肾血管解剖的参考标准。

诊断标准与关键数值

  • 低剂量CT血管造影体型特异性剂量估计9.5±0.8 mGy,标准CT血管造影22.7±4.1 mGy(p<0.001),低剂量CT辐射剂量降低58.2%;低剂量CT的CNR和SNR均显著高于标准CT(p<0.001),定性图像质量两者相似(p>0.05);80例中44例(55.0%)行肾切除术,标准CT对所有变量的准确率为100%,低剂量CT对肾血管数目或早期分支血管的准确率为96.6%、对左侧腰升静脉引流入左肾静脉的准确率为85.7%,各项比较p>0.05。

临床应用与阅片要点

  • 原文结论为使用ASiR-V的低剂量CT血管造影可用于评估潜在活体肾供者的肾血管解剖。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess image quality and diagnostic accuracy of low-dose computed tomography (CT) angiography using adaptive statistical iterative reconstruction V (ASiR-V) for evaluating the anatomy of renal vasculature in potential living renal donors.

MATERIALS AND METHODS: Eighty of 100 potential living renal donors were prospectively enrolled and underwent multiphase CT angiography (e.g., unenhanced, arterial, and venous phases) to evaluate the kidney for donation. Either low-dose using ASiR-V or standard protocol was randomly applied. Image quality was analyzed qualitatively and quantitatively with contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR). Renal artery and vein number, early branching vessel from renal arteries, and drainage of left-sided ascending lumbar vein to left renal vein were assessed. Reference standard for renal vasculature was surgical confirmation.

RESULTS: Size-specific dose estimate of low-dose CT angiography (9.5 ± 0.8 mGy) was significantly lower than standard CT angiography (22.7 ± 4.1 mGy) (p < 0.001). Thus, radiation dose was reduced by 58.2% with low-dose CT. Both CNR and SNR of low-dose CT were significantly higher than those of standard CT (p < 0.001). Between the two CT methods, image quality was similar qualitatively (p > 0.05). Of 80 participants, 44 (55.0%) underwent nephrectomy. Both CT methods accurately predicted the anatomy of renal vasculature (standard CT, 100% for all variables; low-dose CT, 96.6% for renal vessel number or early branching vessel and 85.7% for drainage of left-sided ascending lumbar vein to left renal vein; p > 0.05 for all comparisons).

CONCLUSION: Low-dose CT angiography using ASiR-V is useful to evaluate renal vasculature for potential living renal donors.

KEY POINTS: • In this prospective study, adaptive statistical iterative reconstruction V (ASiR-V) allowed 58.2% dose reduction while maintaining diagnostic image quality for renal vessels. • As compared with the standard protocol, the dose with ASiR-V was significantly lower (9.5 ± 0.8 mGy) than with standard computed tomography (CT) angiography (22.7 ± 4.1 mGy). • Low-dose CT using ASiR-V is useful for living donor evaluation before nephrectomy.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Han WK, Na JC, Park SY, et al. Low-dose CT angiography using ASiR-V for potential living renal donors: a prospective analysis of image quality and diagnostic accuracy. Eur Radiol. 2019. PMID: 31471753. doi:10.1007/s00330-019-06423-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。