前列腺癌与良性前列腺增生的鉴别:体素内不相干运动与单指数模型直方图分析比较,以MR引导下靶向穿刺活检为病理参考
纳入30例患者(16个前列腺癌病灶、20个良性前列腺增生结节),以MR引导下穿刺活检为病理参考,比较IVIM与单指数模型直方图参数鉴别前列腺癌与良性前列腺增生的诊断效能。结果显示两种模型均有诊断价值,IVIM模型似乎并不优于单指数模型,二者联合未增加显著信息。
要点
- 前列腺癌的D直方图均值、75th、90th及最大值显著低于良性前列腺增生。
- D最大值、f均值、ADC最小值的诊断效能较高,AUC分别为0.925、0.881、0.969。
- IVIM模型与单指数模型诊断效能无显著差异,二者联合未提高诊断效能。
核心结论
- IVIM与单指数模型的直方图分析均是鉴别前列腺癌与良性前列腺增生的有用方法。
- IVIM模型的诊断效能似乎并不优于单指数模型。
- IVIM与单指数模型联合并未比单一模型增加显著信息。
研究设计与样本
- 研究纳入30例患者,分析16个前列腺癌病灶和20个良性前列腺增生结节。
- DWI图像经Matlab R2015b软件处理,采用IVIM和单指数模型定量D、D*、f和ADC。
- 以MR引导下靶向穿刺活检作为病理参考标准。
诊断标准与关键数值
- D直方图均值、75th、90th及最大值在前列腺癌显著低于良性前列腺增生。
- D*最小值及10th在前列腺癌显著低于良性前列腺增生。
- f直方图均值、最小值、10th、25th、50th、75th、90th、最大值及偏度在前列腺癌与良性前列腺增生间差异显著。
- ADC直方图均值、最小值、10th、25th、50th、75th、90th、最大值及峰度在前列腺癌显著低于良性前列腺增生。
- D最大值AUC=0.925、f均值AUC=0.881、ADC最小值AUC=0.969,诊断效能高于其他参数。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the diagnostic performance of histogram analysis of intravoxel incoherent motion (IVIM) parameters for differentiating prostate cancer (PCa) from benign prostatic hyperplasia (BPH), and compare with the monoexponential model, with in-bore MR-guided biopsy as pathological reference.
METHODS: Thirty patients were included in this study. DWI images were processed with Matlab R2015b software by IVIM and monoexponential model for quantitation of diffusion coefficient (D), pseudo diffusion coefficient (D*), perfusion fraction (f), and apparent diffusion coefficient (ADC). The multiparametric data were compared between PCa and BPH group. Correlations between parameters and Gleason scores of PCa were assessed with Spearman rank test. ROC analysis was used to evaluate and compare the diagnostic ability of each parameter for discriminating PCa from BPH. Logistic regression model was used to evaluate the diagnostic performance of combination of different histogram parameters.
RESULTS: Sixteen PCa lesions and 20 BPH nodules were analyzed in this study. For IVIM-derived D, the histogram mean, 75th, 90th, and max of PCa were significantly lower than BPH. PCa had significantly lower min and 10th D* than BPH. For f, histogram mean, min, 10th, 25th, 50th, 75th, 90th, max and skew showed significant differences between PCa and BPH. For ADC, PCa were significantly lower than BPH in terms of histogram mean, min, 10th, 25th, 50th, 75th, 90th, max and kurtosis. Histogram mean D and min, 25th D* show significantly negative correlation with Gleason score (r = - 0.582, - 0.534, - 0.554, respectively). Histogram max D and mean f and min ADC showed higher diagnostic performance than other parameters (AUC = 0.925, 0.881, 0.969, respectively). The IVIM model (combined with max D, min D* and mean f) (AUC = 0.950 [0.821, 0.995]) didn't show significant difference from the monoexponential model (AUC = 0.969 [0.849, 0.999], p = 0.23). Besides, combination of the IVIM and monoexponential model didn't improve diagnostic performance compared with the single model (p = 0.362 and 0.763, respectively).
CONCLUSIONS: Histogram analyses of IVIM and monoexponential model were both useful methods for discriminating PCa from BPH. The diagnostic performance of IVIM model seemed to be not superior to that of monoexponential model. Combination of IVIM and monoexponential model did not add significant information to the single model alone.
引用
- Cui Y, Li C, Liu Y, et al. Differentiation of prostate cancer and benign prostatic hyperplasia: comparisons of the histogram analysis of intravoxel incoherent motion and monoexponential model with in-bore MR-guided biopsy as pathological reference. Abdom Radiol (NY). 2020. PMID: 31549212. doi:10.1007/s00261-019-02227-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。