文献速递技术与安全骨肌泌尿生殖CT

全身扫描用面阵探测器立位CT的研制:体模研究、工作流程效能、重力对人体影响及潜在临床价值

Development of Upright Computed Tomography With Area Detector for Whole-Body Scans: Phantom Study, Efficacy on Workflow, Effect of Gravity on Human Body, and Potential Clinical Impact.
PubMed 文献 · Invest Radiol · 2020-01-01

本研究研制了15秒内完成全躯干三维扫描的立位CT,体模显示其噪声、空间分辨率和CT值与仰卧位CT相当。32名无症状志愿者前瞻性同日接受立位与仰卧位CT,立位CT总进出时间较仰卧位减少56%,立位下上腔静脉面积缩小80%、下腔静脉面积增大37%,膀胱颈和肛直肠交界显著下降,女性膀胱颈下降更明显。立位CT在3例患者中显示了常规CT未显现的腰椎椎间孔狭窄、膀胱脱垂和腹股沟疝。

要点

  • 立位CT可在15秒内完成全躯干三维扫描,体模噪声、空间分辨率和CT值与仰卧位CT相当。
  • 立位CT总进出时间41±9秒,较仰卧位91±15秒减少56%(P<0.001)。
  • 立位下上腔静脉面积较仰卧位缩小80%,下腔静脉面积增大37%,主动脉面积无显著差异。

核心结论

  • 立位CT物理特性与仰卧位CT相当,显著缩短检查进出时间。
  • 重力对腔静脉面积的影响因体位而异,立位下上腔静脉缩小、下腔静脉增大,主动脉无显著变化。
  • 立位下盆底显著下降,女性膀胱颈下降较男性更明显。
  • 立位CT可能有助于常见功能性疾病(腰椎滑脱、盆底脱垂、腹股沟疝)的客观诊断及分级或临床意义判断。

研究设计与样本

  • 体模研究比较仰卧位与立位CT的噪声特性、空间分辨率和CT值。
  • 32名无症状志愿者(48.4±11.5岁)前瞻性同日接受相同扫描协议的立位和仰卧位CT。
  • 对志愿者进行问卷调查,评估使用立柱的稳定性(封闭式问题)及每次检查全程的安全性和舒适性(均采用5分制)。
  • 采用Wilcoxon符号秩检验和Mann-Whitney U检验评估总进出时间及重力对大循环和盆底的影响。
  • 大循环评估上腔静脉或升主动脉、膈肌水平、下腔静脉或腹主动脉3个点的面积;盆底评估膀胱颈和肛直肠交界至耻尾线的距离。

关键影像表现/征象

  • 立位CT噪声特性、空间分辨率和CT值与仰卧位CT相当。
  • 立位下上腔静脉面积39.9±17.4 mm较仰卧位195.4±52.2 mm缩小80%(P<0.001)。
  • 立位下膈肌水平面积428.3±87.9 mm与仰卧位426.1±82.0 mm相似(P=0.866)。
  • 立位下下腔静脉面积346.6±96.9 mm较仰卧位252.5±93.1 mm增大37%(P<0.001)。
  • 立位下主动脉3个水平面积与仰卧位无显著差异。

诊断标准与关键数值

  • 体模评估指标包括噪声特性、空间分辨率和CT值。
  • 志愿者问卷采用5分制评估安全性和舒适性,平均评分分别为4.2和3.8。
  • 盆底评估采用膀胱颈至耻尾线和肛直肠交界至耻尾线的距离。

临床应用与阅片要点

  • 所有志愿者均回答使用立柱稳定,大多数报告整个立位CT检查过程感觉安全(平均4.2分)和舒适(平均3.8分)。
  • 立位CT在3例患者中显示了腰椎椎间孔狭窄、膀胱脱垂和腹股沟疝,并以常规CT未显现的方式明确了疾病分级或临床意义。
  • 立位CT总进出时间41±9秒较仰卧位91±15秒减少56%(P<0.001)。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Multiple human systems are greatly affected by gravity, and many disease symptoms are altered by posture. However, the overall anatomical structure and pathophysiology of the human body while standing has not been thoroughly analyzed due to the limitations of various upright imaging modalities, such as low spatial resolution, low contrast resolution, limited scan range, or long examination time. Recently, we developed an upright computed tomography (CT), which enables whole-torso cross-sectional scanning with 3-dimensional acquisition within 15 seconds. The purpose of this study was to evaluate the performance, workflow efficacy, effects of gravity on a large circulation system and the pelvic floor, and potential clinical impact of upright CT.

MATERIALS AND METHODS: We compared noise characteristics, spatial resolution, and CT numbers in a phantom between supine and upright CT. Thirty-two asymptomatic volunteers (48.4 ± 11.5 years) prospectively underwent both CT examinations with the same scanning protocols on the same day. We conducted a questionnaire survey among these volunteers who underwent the upright CT examination to determine their opinions regarding the stability of using the pole throughout the acquisition (closed question), as well as safety and comfortability throughout each examination (both used 5-point scales). The total access time (sum of entry time and exit time) and gravity effects on a large circulation system and the pelvic floor were evaluated using the Wilcoxon signed-rank test and the Mann-Whitney U test. For a large circulation system, the areas of the vena cava and aorta were evaluated at 3 points (superior vena cava or ascending aorta, at the level of the diaphragm, and inferior vena cava or abdominal aorta). For the pelvic floor, distances were evaluated from the bladder neck to the pubococcygeal line and the anorectal junction to the pubococcygeal line. We also examined the usefulness of the upright CT in patients with functional diseases of spondylolisthesis, pelvic floor prolapse, and inguinal hernia.

RESULTS: Noise characteristics, spatial resolution, and CT numbers on upright CT were comparable to those of supine CT. In the volunteer study, all volunteers answered yes regarding the stability of using the pole, and most reported feeling safe (average rating of 4.2) and comfortable (average rating of 3.8) throughout the upright CT examination. The total access time for the upright CT was significantly reduced by 56% in comparison with that of supine CT (upright: 41 ± 9 seconds vs supine: 91 ± 15 seconds, P < 0.001). In the upright position, the area of superior vena cava was 80% smaller than that of the supine position (upright: 39.9 ± 17.4 mm vs supine: 195.4 ± 52.2 mm, P < 0.001), the area at the level of the diaphragm was similar (upright: 428.3 ± 87.9 mm vs supine: 426.1 ± 82.0 mm, P = 0.866), and the area of inferior vena cava was 37% larger (upright: 346.6 ± 96.9 mm vs supine: 252.5 ± 93.1 mm, P < 0.001), whereas the areas of aortas did not significantly differ among the 3 levels. The bladder neck and anorectal junction significantly descended (9.4 ± 6.0 mm and 8.0 ± 5.6 mm, respectively, both P < 0.001) in the standing position, relative to their levels in the supine position. This tendency of the bladder neck to descend was more prominent in women than in men (12.2 ± 5.2 mm in women vs 6.7 ± 5.6 mm in men, P = 0.006). In 3 patients, upright CT revealed lumbar foraminal stenosis, bladder prolapse, and inguinal hernia; moreover, it clarified the grade or clinical significance of the disease in a manner that was not apparent on conventional CT.

CONCLUSIONS: Upright CT was comparable to supine CT in physical characteristics, and it significantly reduced the access time for examination. Upright CT was useful in clarifying the effect of gravity on the human body: gravity differentially affected the volume and shape of the vena cava, depending on body position. The pelvic floor descended significantly in the standing position, compared with its location in the supine position, and the descent of the bladder neck was more prominent in women than in men. Upright CT could potentially aid in objective diagnosis and determination of the grade or clinical significance of common functional diseases.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Jinzaki M, Yamada Y, Nagura T, et al. Development of Upright Computed Tomography With Area Detector for Whole-Body Scans: Phantom Study, Efficacy on Workflow, Effect of Gravity on Human Body, and Potential Clinical Impact. Invest Radiol. 2020. PMID: 31503082. doi:10.1097/RLI.0000000000000603

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。