文献速递儿科影像胸部腹部CT

高螺距双源CT作为清醒婴幼儿胸腹部快速评估技术的初步临床经验

Initial clinical experience with high-pitch dual-source CT as a rapid technique for thoraco-abdominal evaluation in awake infants and young children.
PubMed 文献 · Clin Radiol · 2019-09-24

研究纳入53例婴幼儿,在双源128排CT上行高螺距(≥1.5)或标准螺距(<1.5)胸腹部扫描,比较图像质量与辐射剂量。高螺距CT平均SSDE为1.96±1 mGy,标准螺距CT为2.2±1 mGy(p=0.3);客观图像噪声分别为11±3与11±5(p=0.7),均无显著差异。作者认为超快速高螺距CT无需镇静即可完成,可能作为婴幼儿麻醉下MR检查的替代方案。

要点

  • 高螺距CT可在清醒婴幼儿中无需镇静完成胸腹部扫描,图像质量满足诊断。
  • 高螺距CT平均SSDE为1.96±1 mGy,标准螺距CT为2.2±1 mGy,两者差异无统计学意义(p=0.3)。
  • 高螺距CT与标准螺距CT的客观图像噪声分别为11±3与11±5,无显著差异(p=0.7)。

核心结论

  • 超快速高螺距CT无需镇静即可在婴幼儿中完成,作者认为可能作为麻醉下MR检查的替代方案。

研究设计与样本

  • 研究纳入53例儿科患者(年龄24.1±2个月),在双源128排多排CT系统上行胸部或腹部高螺距CT(≥1.5)与标准螺距CT(<1.5),由两名儿科放射科医师评估诊断信心、图像伪影与图像噪声。

诊断标准与关键数值

  • 图像质量由两名儿科放射科医师评估诊断信心、图像伪影和图像噪声。
  • 高螺距CT平均SSDE为1.96±1 mGy,标准螺距CT为2.2±1 mGy(p=0.3)。
  • 高螺距CT客观图像噪声为11±3,标准螺距CT为11±5(p=0.7)。

临床应用与阅片要点

  • 作者认为超快速高螺距CT无需镇静,可能作为婴幼儿麻醉下MR检查的替代方案。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate dual-source high-pitch computed tomography (HPCT) imaging of the chest and abdomen as a rapid scanning technique to obtain diagnostic-quality imaging evaluation of infants and young children without sedation.

MATERIALS AND METHODS: Fifty-three paediatric patients (age 24.1±2 months) who underwent chest or abdomen HPCT (≥1.5) and standard pitch CT (SPCT, <1.5) on a dual-source 128-row multidetector CT system were included in the study. Image quality assessment was performed by two paediatric radiologists for diagnostic confidence, image artefacts, and image noise. Objective image noise was measured.

RESULTS: Most of the CT examinations were performed in children who were >1 year old (n=15 and n=20) followed by ≤1 year old (n=8 and n=10) in SPCT and HPCT, respectively. The mean radiation dose (SSDE) from HPCT was 1.96±1 mGy compared to 2.2±1 mGy for SPCT (p=0.3). No major artefacts were reported and overall image quality of all HPCT examinations was acceptable diagnostically. In addition, objective image noise values were not significantly different between HPCT compared with SPCT (11±3 versus 11±5, p=0.7).

CONCLUSION: Ultra-fast, HPCT can be performed without the need for sedation as a potential alternative to anaesthetised magnetic resonance imaging in infants and young children.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Tabari A, Patino M, Westra SJ, et al. Initial clinical experience with high-pitch dual-source CT as a rapid technique for thoraco-abdominal evaluation in awake infants and young children. Clin Radiol. 2019. PMID: 31561835. doi:10.1016/j.crad.2019.08.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。