钆塞酸对肝脏动脉多期磁共振成像图像质量的影响:与钆特酸增强MRI的对比研究
回顾性纳入211例患者,比较钆塞酸(108例)与钆特酸(103例)在3.0T单次屏气三重动脉期4D eTHRIVE Keyhole序列上的图像质量。钆塞酸组动脉期图像质量显著低于钆特酸组,但平扫图像评分更优(P<0.001);两组图像质量均从第一至第三动脉期逐渐改善(P<0.003)。
要点
- 钆塞酸增强MRI三重动脉期图像质量显著低于钆特酸增强MRI。
- 钆塞酸组平扫图像评分优于钆特酸组(P<0.001)。
- 两组图像质量均从第一至第三动脉期逐渐改善(P<0.003),第三动脉期最佳。
核心结论
- 静脉注射钆塞酸可能对4D eTHRIVE Keyhole技术三重动脉期MRI的图像质量产生不利影响;第三动脉期图像质量最佳,可作为关键扫描。
研究设计与样本
- 回顾性研究,211例患者按所用对比剂分为钆塞酸组(108例)和钆特酸组(103例),均行3.0T MRI单次屏气三重动脉期4D eTHRIVE Keyhole序列采集。
诊断标准与关键数值
- 采用5分法对平扫及三重动脉期的图像伪影、肝内血管和肝边缘锐利度及整体图像质量进行定性评估;钆塞酸组三重动脉期图像质量显著低于钆特酸组(P<0.001),而钆塞酸组平扫图像评分更优(P<0.001);两组整体图像质量从第一至第三动脉期逐渐改善(P<0.003)。
临床应用与阅片要点
- 作者指出第三动脉期图像质量最佳,可作为关键扫描。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare the effects of gadoxetic acid and gadoteric acid on the image quality of single-breath-hold, triple (first, second, and third) arterial hepatic magnetic resonance imaging (MRI).
METHODS: Two hundred and eleven patients were divided into two groups according to the contrast materials used (gadoxetic acid, 108 patients and gadoteric acid, 103 patients). All 3.0-T MR examinations included triple arterial phase acquisition using the 4D enhanced T1-weighted high-resolution isotropic volume examination (eTHRIVE) keyhole technique. The image qualities of the pre-contrast and triple arterial phases were assessed in terms of image artifacts, sharpness of the intrahepatic vessel and liver edge, and overall image quality with a 5-point scale for qualitative analysis.
RESULTS: The image quality of gadoxetic acid-enhanced liver MRI in the triple arterial phases was significantly degraded compared with that of gadoteric acid-enhanced liver MRI, although better image scores were observed in the pre-contrast images in the gadoxetic acid group (P < 0.001). The overall image quality gradually improved from the first to the third arterial phases in both groups (P < 0.003).
CONCLUSIONS: Intravenous gadoxetic acid could have a detrimental effect on image quality of triple arterial phase MRI with the 4D eTHRIVE Keyhole technique. The third arterial phase images had the best image qualities; thus, they could be used as key scans.
引用
- Sim KC, Park BJ, Han NY, et al. Effects of gadoxetic acid on image quality of arterial multiphase magnetic resonance imaging of liver: comparison study with gadoteric acid-enhanced MRI. Abdom Radiol (NY). 2019. PMID: 31471706. doi:10.1007/s00261-019-02202-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。