影响CT胰腺分割深度学习方法成功率的技术与临床因素
该研究在82例门静脉期腹部CT上使用深度卷积神经网络进行胰腺分割,平均Dice相似系数为78%±8%。腹内脂肪、胰腺体积及胰腺周围CT衰减值与分割精度显著相关,而身高、性别及胰腺平均CT衰减值无显著相关。
要点
- 腹内脂肪越多、胰腺周围脂肪累积越明显,胰腺分割Dice相似系数越高。
- 胰腺体积越大、胰腺内CT衰减值标准差越大,分割精度越高。
- 胰腺周围5 mm邻域中位及平均CT衰减值越低,分割精度越高。
核心结论
- 腹内脂肪增加及胰腺内或周围脂肪累积是与更准确胰腺分割相关的主要因素。
- 研究结果可能用于评估特定扫描或数据集的胰腺分割难度,并识别对更具挑战性胰腺分割更有效的方法。
研究设计与样本
- 研究经IRB批准并符合HIPAA,使用深度卷积神经网络在公开数据库中82例门静脉期腹部CT扫描上进行胰腺分割,包括53名男性和29名女性。
- 以Dice相似系数评估分割精度,并与人口学及临床数据、CT技术因素和CT影像表现进行相关性分析。
关键影像表现/征象
- 平均Dice相似系数为78%±8%。
- Dice相似系数与体重指数(r=0.34,p<0.01)、腹内脂肪(r=0.51,p<0.0001)、胰腺体积(r=0.41,p=0.001)、胰腺内CT衰减值标准差(r=0.30,p=0.01)、胰腺紧邻区域中位CT衰减值(r=-0.53,p<0.0001)及平均CT衰减值(r=-0.52,p<0.0001)显著相关。
- Dice相似系数与身高、性别及胰腺平均CT衰减值无显著相关性。
诊断标准与关键数值
- 分割精度以Dice相似系数评估,平均值为78%±8%。
临床应用与阅片要点
- 阅片时可参考腹内脂肪、胰腺体积及胰腺周围CT衰减值等因素预判胰腺分割难度。
- 作者认为研究结果可能用于评估特定扫描或数据集的胰腺分割难度,并识别对更具挑战性胰腺分割更有效的方法。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Accurate pancreas segmentation has application in surgical planning, assessment of diabetes, and detection and analysis of pancreatic tumors. Factors that affect pancreas segmentation accuracy have not been previously reported. The purpose of this study is to identify technical and clinical factors that adversely affect the accuracy of pancreas segmentation on CT.
METHOD AND MATERIALS: In this IRB and HIPAA compliant study, a deep convolutional neural network was used for pancreas segmentation in a publicly available archive of 82 portal-venous phase abdominal CT scans of 53 men and 29 women. The accuracies of the segmentations were evaluated by the Dice similarity coefficient (DSC). The DSC was then correlated with demographic and clinical data (age, gender, height, weight, body mass index), CT technical factors (image pixel size, slice thickness, presence or absence of oral contrast), and CT imaging findings (volume and attenuation of pancreas, visceral abdominal fat, and CT attenuation of the structures within a 5 mm neighborhood of the pancreas).
RESULTS: The average DSC was 78% ± 8%. Factors that were statistically significantly correlated with DSC included body mass index (r = 0.34, p < 0.01), visceral abdominal fat (r = 0.51, p < 0.0001), volume of the pancreas (r = 0.41, p = 0.001), standard deviation of CT attenuation within the pancreas (r = 0.30, p = 0.01), and median and average CT attenuation in the immediate neighborhood of the pancreas (r = -0.53, p < 0.0001 and r = -0.52, p < 0.0001). There were no significant correlations between the DSC and the height, gender, or mean CT attenuation of the pancreas.
CONCLUSION: Increased visceral abdominal fat and accumulation of fat within or around the pancreas are major factors associated with more accurate segmentation of the pancreas. Potential applications of our findings include assessment of pancreas segmentation difficulty of a particular scan or dataset and identification of methods that work better for more challenging pancreas segmentations.
引用
- Bagheri MH, Roth H, Kovacs W, et al. Technical and Clinical Factors Affecting Success Rate of a Deep Learning Method for Pancreas Segmentation on CT. Acad Radiol. 2019. PMID: 31537506. doi:10.1016/j.acra.2019.08.014