儿科CT细微肝脏病灶评估的模拟范式:检测性能与信心
研究基于30例0-10岁儿童腹部增强CT回顾性构建模拟低对比肝病灶(≤6 mm)并加入噪声模拟25%和50%剂量降低,9名放射科医师标注病灶并评分信心。结果显示随剂量降低检测敏感度显著下降(P < .001),但全剂量与25%降剂量信心无差异(P = .866)。
要点
- 随辐射剂量降低,模拟肝病灶检测敏感度显著下降(P < .001)。
- 全剂量与25%降剂量信心无差异(P = .866),读者未察觉敏感度下降。
- 亚专科不影响敏感度或假阳性结果。
核心结论
- 随剂量降低,病灶检测敏感度显著下降,但全剂量与25%降剂量扫描间信心无变化。
- 作者提示读者未察觉敏感度下降,临床降剂量工作应考虑到这一点。
研究设计与样本
- 回顾性收集2012年7月1日至2016年7月1日30例0-10岁儿童腹部增强CT,研究豁免机构审查委员会批准。
- 通过软件数字插入0至3个低对比肝病灶(≤6 mm),并加入噪声模拟容积CT剂量指数降低25%和50%。
- 儿科、腹部和住院放射科医师各3名,分三次通过在线界面阅片90组数据,标注病灶位置并评分信心(0-100分)。
关键影像表现/征象
- 模拟低对比肝病灶直径≤6 mm,通过数字插入并加入噪声模拟剂量降低。
诊断标准与关键数值
- 检测敏感度随辐射剂量降低而显著下降(P < .001)。
- 全剂量与25%降剂量检查的平均信心显著高于50%降剂量检查(P = .011和P = .012),但全剂量与25%降剂量间无差异(P = .866)。
- 剂量不是完成每个病例时间的显著预测因子,亚专科不是敏感度或假阳性结果的显著预测因子。
临床应用与阅片要点
- 作者指出读者未察觉降剂量导致的敏感度下降,临床降剂量工作应考虑到这一点。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To create and validate a systematic observer performance platform for evaluation of simulated liver lesions at pediatric CT and to test this paradigm to measure the effect of radiation dose reduction on detection performance and reader confidence.
MATERIALS AND METHODS: Thirty normal pediatric (from patients aged 0-10 years) contrast material-enhanced, de-identified abdominal CT scans obtained from July 1, 2012, through July 1, 2016, were retrospectively collected from the clinical database. The study was exempt from institutional review board approval. Zero to three simulated, low-contrast liver lesions (≤6 mm) were digitally inserted by using software, and noise was added to simulate reductions in volume CT dose index (representing radiation dose estimation) of 25% and 50%. Pediatric, abdominal, and resident radiologists (three of each) reviewed 90 data sets in three sessions using an online interface, marking each lesion location and rating confidence (scale, 0-100). Statistical analysis was performed by using software.
RESULTS: Mixed-effects models revealed a significant decrease in detection sensitivity as radiation dose decreased (P < .001). The mean confidence of the full-dose and 25% dose reduction examinations was significantly higher than that of the 50% dose reduction examinations (P = .011 and .012, respectively) but not different from one another (P = .866). Dose was not a significant predictor of time to complete each case, and subspecialty was not a significant predictor of sensitivity or false-positive results.
CONCLUSION: Sensitivity for lesion detection significantly decreased as dose decreased; however, confidence did not change between the full-dose and 25% reduced-dose scans. This suggests that readers are unaware of this decrease in performance, which should be accounted for in clinical dose reduction efforts.Keywords: Abdomen/GI, CT, Liver, Observer Performance, Pediatrics, Perception Image© RSNA, 2019.
引用
- Ngo JS, Solomon JB, Samei E, et al. A Simulation Paradigm for Evaluation of Subtle Liver Lesions at Pediatric CT: Performance and Confidence. Radiol Imaging Cancer. 2019. PMID: 33778672. doi:10.1148/rycan.2019190027
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。