文献速递腹部MR

无症状个体肝脏与胰腺偶然性脂肪沉积的相关性研究

Correlation between incidental fat deposition in the liver and pancreas in asymptomatic individuals.
PubMed 文献 · Abdom Radiol (NY) · 2020-01-01

前瞻性纳入58例健康潜在肝供体,行3T MRI单 voxel MRS、双回波Dixon和多回波Dixon,比较肝脏和胰腺质子密度脂肪分数(PDFF)。多回波Dixon在鉴别正常肝脂肪(PDFF≤6%)与轻度脂肪沉积(PDFF 6-33%)时敏感度85%、特异度96%、准确率89%,并显示肝与胰腺脂肪测量间良好相关(r=0.72)。

要点

  • 多回波Dixon鉴别正常与轻度肝脂肪沉积的敏感度85%、特异度96%、准确率89%,优于双回波Dixon的74%、81%、80%。
  • 肝与胰腺PDFF在多回波Dixon上呈良好相关(r=0.72,p=0.0005),提示可单序列同时评估。
  • 双回波与多回波Dixon在肝PDFF测量上相关良好(r=0.82,p<0.0005)。

核心结论

  • 多回波Dixon在肝脏区分正常肝脂肪与轻度升高肝脂肪具有高准确率;多回波Dixon可用于筛查肝脏和胰腺早期脂肪沉积。

研究设计与样本

  • 前瞻性研究,58例健康潜在肝供体,行腹部3T MRI,包括单voxel MRS、双回波Dixon和多回波Dixon;两名独立阅片者在2个Dixon序列上放置ROI获取肝脏和胰腺PDFF;以MRS为参考比较肝脏PDFF。

关键影像表现/征象

  • 肝脏PDFF分别为MRS 6.3±4.2%、双回波Dixon 5.5±3.9%、多回波Dixon 5.1±4.1%。
  • 胰腺平均PDFF分别为双回波Dixon 7.2±2.8%、多回波Dixon 6.7±3.3%。

诊断标准与关键数值

  • 以PDFF≤6%为正常、PDFF 6-33%为轻度脂肪沉积,双回波Dixon鉴别敏感度74%、特异度81%、准确率80%。
  • 以PDFF≤6%为正常、PDFF 6-33%为轻度脂肪沉积,多回波Dixon鉴别敏感度85%、特异度96%、准确率89%。
  • 双回波与多回波Dixon在肝脏PDFF定量上相关良好(r=0.82,p<0.0005)。
  • 双回波与多回波Dixon在胰腺PDFF定量上相关良好(r=0.58,p<0.0005)。
  • 多回波Dixon测得肝脏脂肪与胰腺脂肪之间相关良好(r=0.72,p=0.0005)。

临床应用与阅片要点

  • 多回波Dixon可作为单序列筛查肝脏和胰腺早期脂肪沉积。
  • 多回波Dixon在区分正常与轻度肝脂肪沉积时准确率高于双回波Dixon。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To explore the utility of two different fat quantification methods in the liver and pancreas and to test the accuracy of multi-echo Dixon as a single sequence in detecting early stage of fat deposition.

METHODS: 58 healthy potential liver donors underwent abdominal 3T MRI, prospectively. Single-voxel MR Spectroscopy (MRS), dual-echo Dixon, and multi-echo Dixon were performed. Two independent readers obtained proton density fat fraction (PDFF) of the liver and pancreas by placing ROIs on the 2 Dixon sequences. Correlation between the two PDFF measurements was assessed in the liver and pancreas. Values in the liver were also compared to those obtained by MRS.

RESULTS: PDFF in the liver was 6.3 ± 4.2%, 5.5 ± 3.9%, and 5.1 ± 4.1% by MRS, dual-echo Dixon, and multi-echo Dixon, respectively. Dual-echo Dixon and multi-echo Dixon showed good correlation in PDFF quantification of the liver (r = 0.82, p < 0.0005). Multi-echo Dixon showed a good correlation (r = 0.72, p = 0.0005) between the fat measured in the liver and in the pancreas. To differentiate between normal (PDFF ≤ 6%) and mild fat deposition (PDFF: 6-33%) in the liver, analysis showed sensitivity, specificity, and accuracy of 74%, 81%, and 80% for dual-echo Dixon and 85%, 96%, and 89% for multi-echo Dixon, respectively. Mean PDFF in the pancreas was 7.2 ± 2.8% and 6.7 ± 3.3%, by dual-echo and multi-echo Dixon, respectively. Dual-echo Dixon and multi-echo Dixon showed good correlation in PDFF quantification of the pancreas (r = 0.58, p < 0.0005).

CONCLUSION: Multi-echo Dixon in liver has high accuracy in distinguishing between subjects with normal liver fat and those with mildly elevated liver fat. Multi-echo Dixon can be used to screen for early fat deposition in the liver and pancreas.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Aliyari Ghasabeh M, Shaghaghi M, Khoshpouri P, et al. Correlation between incidental fat deposition in the liver and pancreas in asymptomatic individuals. Abdom Radiol (NY). 2020. PMID: 31482380. doi:10.1007/s00261-019-02206-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。