无症状个体肝脏与胰腺偶然性脂肪沉积的相关性研究
前瞻性纳入58例健康潜在肝供体,行3T MRI单 voxel MRS、双回波Dixon和多回波Dixon,比较肝脏和胰腺质子密度脂肪分数(PDFF)。多回波Dixon在鉴别正常肝脂肪(PDFF≤6%)与轻度脂肪沉积(PDFF 6-33%)时敏感度85%、特异度96%、准确率89%,并显示肝与胰腺脂肪测量间良好相关(r=0.72)。
要点
- 多回波Dixon鉴别正常与轻度肝脂肪沉积的敏感度85%、特异度96%、准确率89%,优于双回波Dixon的74%、81%、80%。
- 肝与胰腺PDFF在多回波Dixon上呈良好相关(r=0.72,p=0.0005),提示可单序列同时评估。
- 双回波与多回波Dixon在肝PDFF测量上相关良好(r=0.82,p<0.0005)。
核心结论
- 多回波Dixon在肝脏区分正常肝脂肪与轻度升高肝脂肪具有高准确率;多回波Dixon可用于筛查肝脏和胰腺早期脂肪沉积。
研究设计与样本
- 前瞻性研究,58例健康潜在肝供体,行腹部3T MRI,包括单voxel MRS、双回波Dixon和多回波Dixon;两名独立阅片者在2个Dixon序列上放置ROI获取肝脏和胰腺PDFF;以MRS为参考比较肝脏PDFF。
关键影像表现/征象
- 肝脏PDFF分别为MRS 6.3±4.2%、双回波Dixon 5.5±3.9%、多回波Dixon 5.1±4.1%。
- 胰腺平均PDFF分别为双回波Dixon 7.2±2.8%、多回波Dixon 6.7±3.3%。
诊断标准与关键数值
- 以PDFF≤6%为正常、PDFF 6-33%为轻度脂肪沉积,双回波Dixon鉴别敏感度74%、特异度81%、准确率80%。
- 以PDFF≤6%为正常、PDFF 6-33%为轻度脂肪沉积,多回波Dixon鉴别敏感度85%、特异度96%、准确率89%。
- 双回波与多回波Dixon在肝脏PDFF定量上相关良好(r=0.82,p<0.0005)。
- 双回波与多回波Dixon在胰腺PDFF定量上相关良好(r=0.58,p<0.0005)。
- 多回波Dixon测得肝脏脂肪与胰腺脂肪之间相关良好(r=0.72,p=0.0005)。
临床应用与阅片要点
- 多回波Dixon可作为单序列筛查肝脏和胰腺早期脂肪沉积。
- 多回波Dixon在区分正常与轻度肝脂肪沉积时准确率高于双回波Dixon。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To explore the utility of two different fat quantification methods in the liver and pancreas and to test the accuracy of multi-echo Dixon as a single sequence in detecting early stage of fat deposition.
METHODS: 58 healthy potential liver donors underwent abdominal 3T MRI, prospectively. Single-voxel MR Spectroscopy (MRS), dual-echo Dixon, and multi-echo Dixon were performed. Two independent readers obtained proton density fat fraction (PDFF) of the liver and pancreas by placing ROIs on the 2 Dixon sequences. Correlation between the two PDFF measurements was assessed in the liver and pancreas. Values in the liver were also compared to those obtained by MRS.
RESULTS: PDFF in the liver was 6.3 ± 4.2%, 5.5 ± 3.9%, and 5.1 ± 4.1% by MRS, dual-echo Dixon, and multi-echo Dixon, respectively. Dual-echo Dixon and multi-echo Dixon showed good correlation in PDFF quantification of the liver (r = 0.82, p < 0.0005). Multi-echo Dixon showed a good correlation (r = 0.72, p = 0.0005) between the fat measured in the liver and in the pancreas. To differentiate between normal (PDFF ≤ 6%) and mild fat deposition (PDFF: 6-33%) in the liver, analysis showed sensitivity, specificity, and accuracy of 74%, 81%, and 80% for dual-echo Dixon and 85%, 96%, and 89% for multi-echo Dixon, respectively. Mean PDFF in the pancreas was 7.2 ± 2.8% and 6.7 ± 3.3%, by dual-echo and multi-echo Dixon, respectively. Dual-echo Dixon and multi-echo Dixon showed good correlation in PDFF quantification of the pancreas (r = 0.58, p < 0.0005).
CONCLUSION: Multi-echo Dixon in liver has high accuracy in distinguishing between subjects with normal liver fat and those with mildly elevated liver fat. Multi-echo Dixon can be used to screen for early fat deposition in the liver and pancreas.
引用
- Aliyari Ghasabeh M, Shaghaghi M, Khoshpouri P, et al. Correlation between incidental fat deposition in the liver and pancreas in asymptomatic individuals. Abdom Radiol (NY). 2020. PMID: 31482380. doi:10.1007/s00261-019-02206-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。