文献速递心血管CT

光谱光子计数CT用于冠状动脉支架成像:评估界定支架内再狭窄的潜在临床影响

Spectral Photon-Counting Computed Tomography for Coronary Stent Imaging: Evaluation of the Potential Clinical Impact for the Delineation of In-Stent Restenosis.
PubMed 文献 · Invest Radiol · 2020-01-01

本研究在体模中评估光谱光子计数CT(SPCCT)与临床双层CT(DLCT)对冠状动脉支架内再狭窄的显示能力,结果显示SPCCT在定性评估和残余管腔显示上优于DLCT,但图像噪声和对比噪声比DLCT更优。

要点

  • SPCCT MonoE 40 keV图像对支架内残余管腔的显示最佳,10枚支架中7枚可清晰界定。
  • DLCT无法界定任何支架的残余管腔。
  • SPCCT图像噪声和对比噪声比劣于DLCT,但支架内管腔直径测量值更高。

核心结论

  • SPCCT可无创评估支架内再狭窄,对多数支架能可靠显示残余管腔,对全部支架能明确识别或怀疑狭窄;而DLCT无法显示任何支架的残余管腔。

研究设计与样本

  • 体模研究,将软斑块样再狭窄(45 HU,约占支架管腔50%)置入10枚不同冠状动脉支架(直径3 mm),使用研究原型SPCCT与临床双层CT(DLCT;IQon;Philips)以可比采集和重建参数扫描,重建常规多能(PolyE)及4种能量水平(40、60、90、120 keV)的单能(MonoE)图像。

关键影像表现/征象

  • SPCCT对狭窄及邻近残余管腔的定性 delineation 评分显著优于DLCT,最佳重建图像的主观评分DLCT PolyE为2.80±0.42,SPCCT MonoE 40 keV为4.25±1.03。
  • SPCCT和DLCT均能在10枚支架中9枚清晰检出狭窄、10枚怀疑狭窄。
  • SPCCT在10枚支架中7枚可清晰界定狭窄旁残余管腔,测量值为0.64±0.11 mm(占测得支架管腔的34.97%);DLCT无法界定任何支架的残余管腔。
  • SPCCT测得的支架内管腔直径在所有重建中均显著高于DLCT,以MonoE 40 keV最佳(SPCCT:1.80±0.17 mm;DLCT:1.50±0.31 mm)。
  • 图像噪声和对比噪声比DLCT优于SPCCT(对比噪声比:DLCT MonoE 40为31.58±12.54;SPCCT MonoE 40为4.64±1.30)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: In-stent restenosis (ISR) is one of the main long-term complications after coronary stent placement, and the ability to evaluate ISR noninvasively using coronary computed tomography (CT) angiography remains challenging. For this application, spectral photon-counting CT (SPCCT) has the potential to increase image quality and reduce artifacts due to its advanced detector technology.Our study aimed to verify the technical and clinical potential of a novel SPCCT prototype using an ISR phantom setup.

MATERIALS AND METHODS: Soft plaque-like restenosis (45 HU; approximately 50% of the stent lumen) were inserted into 10 different coronary stents (3 mm diameter), which were placed in a vessel phantom and filled with a contrast agent (400 HU). A research prototype SPCCT and a clinical dual-layer CT (DLCT; IQon; Philips) with comparable acquisition and reconstruction parameters were used to scan the phantoms. Conventional polyenergetic (PolyE) and monoenergetic (MonoE) images with 4 different energy levels (40, 60, 90, 120 keV) were reconstructed. Qualitative (delineation of the stenosis and adjacent residual lumen using a 5-point Likert scale) and quantitative (image noise, visible lumen diameter, lumen diameter adjacent to the stenosis, contrast-to-noise ratio of the restenosis) parameters were evaluated for both systems.

RESULTS: The qualitative results averaged over all reconstructions were significantly superior for SPCCT compared with DLCT (eg, subjective rating of the best reconstruction of each scanner: DLCT PolyE: 2.80 ± 0.42 vs SPCCT MonoE 40 keV: 4.25 ± 1.03). Stenosis could be clearly detected in 9 and suspected in 10 of the 10 stents with both SPCCT and DLCT. The residual lumen next to the stenosis was clearly delineable in 7 of 10 stents (0.64 ± 0.11 mm or 34.97% of the measured stent lumen) with SPCCT, while it was not possible to delineate the residual lumen for all stents using DLCT. The measured diameter of the lumen within the stent was significantly higher for SPCCT compared with DLCT in all reconstructions with the best results for the MonoE 40 keV images (SPCCT: 1.80 ± 0.17 mm; DLCT: 1.50 ± 0.31 mm). The image noise and the contrast-to-noise ratio were better for DLCT than for SPCCT (contrast-to-noise ratio: DLCT MonoE 40: 31.58 ± 12.54; SPCCT MonoE 40: 4.64 ± 1.30).

CONCLUSIONS: Spectral photon-counting CT allowed for the noninvasive evaluation of ISR with reliable results regarding the residual lumen for most tested stents and the clear identification or suspicion of stenosis for all stents. In contrast, the residual lumen could not be detected for a single stent using DLCT.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Bratke G, Hickethier T, Bar-Ness D, et al. Spectral Photon-Counting Computed Tomography for Coronary Stent Imaging: Evaluation of the Potential Clinical Impact for the Delineation of In-Stent Restenosis. Invest Radiol. 2020. PMID: 31524765. doi:10.1097/RLI.0000000000000610

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。