文献速递心血管CT

血流动力学显著性冠状动脉狭窄的检测:CT心肌灌注与机器学习CT血流储备分数的对比

Detection of Hemodynamically Significant Coronary Stenosis: CT Myocardial Perfusion versus Machine Learning CT Fractional Flow Reserve.
PubMed 文献 · Radiology · 2019-09-24

前瞻性纳入86例稳定型心绞痛患者共157支目标血管,所有患者均在2周内完成动态CT心肌灌注成像、冠状动脉CT血管成像和有创传统冠状动脉造影血流储备分数检查。以有创血流储备分数为参考,心肌血流量(阈值99 mL/100 mL/min)的AUC为0.97,优于机器学习CT血流储备分数的0.85(P < .001);心肌血流量特异度和诊断准确率亦更高。

要点

  • 动态CT心肌灌注成像的心肌血流量以99 mL/100 mL/min为阈值,AUC达0.97,优于机器学习CT血流储备分数的0.85。
  • 心肌血流量特异度93%高于机器学习CT血流储备分数68%(P < .001),诊断准确率94%高于78%(P = .04)。
  • 两种方法敏感度相似(96% vs 88%,P = .11),但心肌血流量可在较低辐射剂量下完成评估。

核心结论

  • 动态CT心肌灌注成像能够帮助准确评估冠状动脉狭窄的血流动力学意义,且辐射剂量较低。
  • 动态CT心肌灌注成像得出的心肌血流量在识别引起缺血的病变方面优于机器学习CT血流储备分数。

研究设计与样本

  • 前瞻性研究,2017年1月2日至2018年10月17日连续纳入稳定型心绞痛参与者,最终分析86例(平均年龄67岁±12,67例男性)共157支目标血管。
  • 所有参与者均在2周内完成动态CT心肌灌注成像、冠状动脉CT血管成像和有创传统冠状动脉造影血流储备分数检查。
  • 采用受试者工作特征曲线分析评估诊断效能,以有创传统冠状动脉造影血流储备分数为参考标准。

关键影像表现/征象

  • 缺血节段心肌血流量低于非缺血节段和参考节段(参考节段定义为无狭窄血管供血区域):75 mL/100 mL/min±20 vs 148 mL/100 mL/min±22 和 169 mL/100 mL/min±34,均P < .001。
  • 血流动力学显著病变的CT血流储备分数低于血流动力学非显著病变:0.68±0.1 vs 0.83±0.1,P < .001。

诊断标准与关键数值

  • 心肌血流量以99 mL/100 mL/min为阈值,AUC为0.97,优于机器学习CT血流储备分数的AUC 0.85(P < .001)。
  • 基于血管的特异度:心肌血流量93% vs 机器学习CT血流储备分数68%(P < .001)。
  • 基于血管的诊断准确率:心肌血流量94% vs 机器学习CT血流储备分数78%(P = .04)。
  • 敏感度:心肌血流量96% vs 机器学习CT血流储备分数88%(P = .11)。

临床应用与阅片要点

  • 动态CT心肌灌注成像得出的心肌血流量可作为评估冠状动脉狭窄血流动力学意义的参数,阈值99 mL/100 mL/min。
  • 心肌血流量与机器学习CT血流储备分数敏感度相似,但心肌血流量特异度和诊断准确率更高。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Direct intraindividual comparison of dynamic CT myocardial perfusion imaging (MPI) and machine learning (ML)-based CT fractional flow reserve (FFR) has not been explored for diagnosing hemodynamically significant coronary artery disease. Purpose To investigate the diagnostic performance of dynamic CT MPI and ML-based CT FFR for functional assessment of coronary stenosis. Materials and Methods Between January 2, 2017, and October 17, 2018, consecutive participants with stable angina were prospectively enrolled. All participants underwent dynamic CT MPI coronary CT angiography and invasive conventional coronary angiography (CCA) FFR within 2 weeks. Receiver operating characteristic (ROC) curve analysis was used to assess diagnostic performance. Results Eighty-six participants (mean age, 67 years ± 12 [standard deviation]; 67 men) with 157 target vessels were included for final analysis. The mean radiation doses for dynamic CT MPI and coronary CT angiography were 3.6 mSv ± 1.1 and 2.7 mSv ± 0.8, respectively. Myocardial blood flow (MBF) was lower in ischemic segments compared with nonischemic segments and reference segments (defined as the territory of vessels without stenosis) (75 mL/100 mL/min ± 20 vs 148 mL/100 mL/min ± 22 and 169 mL/100 mL/min ± 34, respectively, both P < .001). Similarly, CT FFR was also lower for hemodynamically significant lesions than for hemodynamically nonsignificant lesions (0.68 ± 0.1 vs 0.83 ± 0.1, respectively, P < .001). MBF had the largest area under the ROC curve (AUC) (using 99 mL/100 mL/min as a cutoff) among all parameters, outperforming ML-based CT FFR (AUC = 0.97 vs 0.85, P < .001). The vessel-based specificity and diagnostic accuracy of MBF were higher than those of ML-based CT FFR (93% vs 68%, P < .001 and 94% vs 78%, respectively, P = .04) whereas the sensitivity of both methods was similar (96% vs 88%, respectively, P = .11). Conclusion Dynamic CT myocardial perfusion imaging was able to help accurately evaluate the hemodynamic significance of coronary stenosis using a reduced amount of radiation. In addition, the myocardial blood flow derived from dynamic CT myocardial perfusion imaging outperformed machine learning-based CT fractional flow reserve for identifying lesions causing ischemia. © RSNA, 2019 Online supplemental material is available for this article.See also the editorial by Loewe in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Li Y, Yu M, Dai X, et al. Detection of Hemodynamically Significant Coronary Stenosis: CT Myocardial Perfusion versus Machine Learning CT Fractional Flow Reserve. Radiology. 2019. PMID: 31549943. doi:10.1148/radiol.2019190098

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。