文献速递心血管CT

动态CT灌注负荷心肌血流量比值识别血流动力学显著狭窄的冠心病

Stress Myocardial Blood Flow Ratio by Dynamic CT Perfusion Identifies Hemodynamically Significant CAD.
PubMed 文献 · JACC Cardiovasc Imaging · 2019-09-18

本研究前瞻性纳入82例因胸痛拟行有创冠状动脉造影的患者,采用第二代双源CT行负荷动态CT灌注及冠状动脉CTA,以有创血流储备分数≤0.80为参考标准。结果显示,负荷心肌血流量比值(SFR)诊断血流动力学显著狭窄的AUC为0.91,优于负荷心肌血流量(AUC=0.79;P=0.013),与CTA狭窄≥50%联合后AUC达0.91。

要点

  • SFR定义为狭窄动脉负荷心肌血流量与非病变动脉负荷心肌血流量的比值。
  • SFR诊断血流动力学显著狭窄的敏感度62%、特异度91%,阳性预测值85%、阴性预测值73%。
  • 与CTA狭窄≥50%联合,SFR的AUC为0.91,诊断价值优于单独负荷心肌血流量(AUC=0.79;P=0.013)。

核心结论

  • 动态CT灌注计算SFR是一种识别限流性冠状动脉狭窄的新方法,诊断准确。

研究设计与样本

  • 前瞻性研究,纳入82例因胸痛拟行有创冠状动脉造影的患者,共101支血管(单支或双支病变),采用第二代双源CT行负荷动态CT灌注后行冠状动脉CTA,以有创血流储备分数≤0.80为参考标准。

诊断标准与关键数值

  • SFR定义为狭窄动脉负荷心肌血流量与非病变动脉负荷心肌血流量的比值;以有创血流储备分数≤0.80为血流动力学显著狭窄标准;SFR诊断缺血敏感度62%、特异度91%、阳性预测值85%、阴性预测值73%;CTA狭窄≥50%敏感度95%、特异度43%;SFR联合CTA狭窄≥50%的AUC为0.91,负荷心肌血流量AUC为0.79(P=0.013)。

临床应用与阅片要点

  • 在负荷动态CT灌注联合冠状动脉CTA检查中,可计算SFR辅助识别血流动力学显著狭窄,其特异度高于CTA狭窄≥50%,敏感度低于CTA狭窄≥50%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this study was to evaluate the diagnostic accuracy of stress myocardial blood flow ratio (SFR), a novel parameter derived from stress dynamic computed tomographic perfusion (CTP), for the detection of hemodynamically significant coronary stenosis.

BACKGROUND: A comprehensive cardiac computed tomographic protocol combining coronary computed tomographic angiography (CTA) and CTP can provide a simultaneous assessment of both coronary artery anatomy and ischemia.

METHODS: Patients with chest pain scheduled for invasive angiography were prospectively enrolled in this study. Stress dynamic CTP was performed followed by coronary CTA using a second-generation dual-source computed tomographic system. At subsequent invasive angiography, fractional flow reserve was performed to identify hemodynamically significant stenosis. For each coronary territory, SFR was defined as the ratio of hyperemic myocardial blood flow (MBF) in an artery with stenosis to hyperemic MBF in a nondiseased artery. The diagnostic accuracy of SFR to identify hemodynamically significant stenosis was determined against the reference standard of invasive fractional flow reserve ≤0.80.

RESULTS: A total of 82 patients (mean age 58.5 ± 10 years) with 101 vessels with either 1- or 2-vessel disease were included. By FFR, 48 (47.5%) vessels were deemed hemodynamically significant. Hyperemic MBF and SFR were lower for vessels with hemodynamically significant lesions (95.1 ± 32.4 ml/100 ml/min vs. 142.5 ± 31.2 ml/100 ml/min and 0.66 ± 0.14 vs. 0.90 ± 0.07, respectively; p < 0.01 for both). When compared with ≥50% stenosis by CTA, the specificity for detecting ischemia by SFR increased from 43% to 91%, while the sensitivity decreased from 95% to 62%. Accordingly, the positive and negative predictive values were 85% and 73%, respectively. The combination of stenosis ≥50% by CTA and SFR resulted in an area under the curve of 0.91, which was significantly higher compared with hyperemic MBF (area under the curve = 0.79; p = 0.013).

CONCLUSIONS: Calculation of SFR by dynamic CTP provides a novel and accurate method to identify flow-limiting coronary stenosis.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Yang J, Dou G, He B, et al. Stress Myocardial Blood Flow Ratio by Dynamic CT Perfusion Identifies Hemodynamically Significant CAD. JACC Cardiovasc Imaging. 2019. PMID: 31542524. doi:10.1016/j.jcmg.2019.06.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。