文献速递心血管MR

心脏磁共振评估心肌梗死后非罪犯病变:与血流储备分数比较

Cardiac Magnetic Resonance for Evaluating Nonculprit Lesions After Myocardial Infarction: Comparison With Fractional Flow Reserve.
PubMed 文献 · JACC Cardiovasc Imaging · 2019-09-18

研究纳入77例STEMI合并至少1处中等狭窄非罪犯病变患者,于初次介入后1个月行CMR与FFR检查,以FFR≤0.80为血流动力学梗阻标准;CMR与FFR评估一致性中等至良好,完全定量、半定量与视觉分析诊断效能相似。

要点

  • 以FFR≤0.80为参考,心肌灌注磁共振血流储备AUC 0.82,敏感度82%、特异度71%。
  • 负荷心肌血流量AUC 0.76,敏感度69%、特异度77%。
  • 视觉分析AUC 0.74,完全定量分析未提高诊断效能(所有P>0.05)。

核心结论

  • CMR与FFR在评估STEMI多支病变患者非罪犯病变时一致性中等至良好,完全定量、半定量与视觉分析诊断效能相似。

研究设计与样本

  • 研究纳入77例STEMI合并至少1处中等狭窄(直径狭窄50%至90%)非罪犯病变患者,于初次介入后1个月行CMR和侵入性冠状动脉造影及FFR测量。

关键影像表现/征象

  • CMR成像方案包括负荷与静息灌注、电影成像和晚期钆增强。

诊断标准与关键数值

  • 血流动力学梗阻定义为FFR≤0.80,31例(40%)患者存在血流动力学梗阻性非罪犯病变。
  • 视觉分析AUC为0.74(95%CI:0.62至0.83),敏感度73%、特异度70%。
  • 半定量分析中,负荷信号强度时间曲线相对上升斜率AUC为0.66(95%CI:0.54至0.77),相对上升斜率衍生的心肌血流储备AUC为0.71(95%CI:0.59至0.81)。
  • 完全定量分析未提高诊断效能(所有P>0.05)。
  • 负荷心肌血流量AUC为0.76(95%CI:0.64至0.85),敏感度69%、特异度77%;心肌血流储备AUC为0.82(95%CI:0.71至0.90),敏感度82%、特异度71%。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study sought to determine the agreement between cardiac magnetic resonance (CMR) imaging and invasive measurements of fractional flow reserve (FFR) in the evaluation of nonculprit lesions after ST-segment elevation myocardial infarction (STEMI). In addition, we investigated whether fully quantitative analysis of myocardial perfusion is superior to semiquantitative and visual analysis.

BACKGROUND: The agreement between CMR and FFR in the evaluation of nonculprit lesions in patients with STEMI with multivessel disease is unknown.

METHODS: Seventy-seven patients with STEMI with at least 1 intermediate (diameter stenosis 50% to 90%) nonculprit lesion underwent CMR and invasive coronary angiography in conjunction with FFR measurements at 1 month after primary intervention. The imaging protocol included stress and rest perfusion, cine imaging, and late gadolinium enhancement. Fully quantitative, semiquantitative, and visual analysis of myocardial perfusion were compared against a reference of FFR. Hemodynamically obstructive was defined as FFR ≤0.80.

RESULTS: Hemodynamically obstructive nonculprit lesions were present in 31 (40%) patients. Visual analysis displayed an area under the curve (AUC) of 0.74 (95% confidence interval [CI]: 0.62 to 0.83), with a sensitivity of 73% and a specificity of 70%. For semiquantitative analysis, the relative upslope of the stress signal intensity time curve and the relative upslope derived myocardial flow reserve had respective AUCs of 0.66 (95% CI: 0.54 to 0.77) and 0.71 (95% CI: 0.59 to 0.81). Fully quantitative analysis did not augment diagnostic performance (all p > 0.05). Stress myocardial blood flow displayed an AUC of 0.76 (95% CI: 0.64 to 0.85), with a sensitivity of 69% and a specificity of 77%. Similarly, MFR displayed an AUC of 0.82 (95% CI: 0.71 to 0.90), with a sensitivity of 82% and a specificity of 71%.

CONCLUSIONS: CMR and FFR have moderate-good agreement in the evaluation of nonculprit lesions in patients with STEMI with multivessel disease. Fully quantitative, semiquantitative, and visual analysis yield similar diagnostic performance.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Everaars H, van der Hoeven NW, Janssens GN, et al. Cardiac Magnetic Resonance for Evaluating Nonculprit Lesions After Myocardial Infarction: Comparison With Fractional Flow Reserve. JACC Cardiovasc Imaging. 2019. PMID: 31542525. doi:10.1016/j.jcmg.2019.07.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。