用于判断表现为部分实性结节的孤立性肺结节侵袭性的影像组学模型
本回顾性研究纳入119例经病理确诊的部分实性磨玻璃结节患者(训练组83例、测试组36例),基于平扫CT提取影像组学特征并构建CT特征模型、影像组学标签模型及联合预测列线图。影像组学标签模型在训练组和测试组的AUC分别为0.854和0.813,联合列线图AUC为0.888。
要点
- 影像组学标签模型区分浸润性腺癌与微浸润性腺癌的测试组AUC为0.813。
- 联合病灶形状与影像组学标签的列线图AUC达0.888。
- CT特征模型中病灶形状和实性成分直径是显著特征,AUC为0.755。
核心结论
- 影像组学标签可为区分浸润性腺癌与微浸润性腺癌提供重要参考,联合CT形态学可显著提升鉴别能力。
- 列线图可能对临床决策具有较高参考价值。
研究设计与样本
- 回顾性研究纳入119例经组织病理学确诊的部分实性磨玻璃结节患者,分为训练组83例和测试组36例。
- 基于平扫CT图像提取影像组学特征,使用R软件处理定性和定量数据。
- 构建并比较CT特征模型、影像组学标签模型和联合预测模型。
关键影像表现/征象
- 从术前CT图像共提取396个影像组学特征。
- MaxIntensity、RMS、ZonePercentage和LongRunEmphasis_angle0_offset7四个特征被确定为构建影像组学标签模型的最佳判别特征。
- 病灶形状和实性成分直径被确认为构建CT特征模型的显著特征。
诊断标准与关键数值
- 影像组学标签模型训练组AUC为0.854(95%CI:0.774~0.934),测试组AUC为0.813(95%CI:0.670~0.955)。
- CT特征模型AUC为0.755(95%CI:0.648~0.843)。
- 联合病灶形状与影像组学标签的列线图AUC为0.888(95%CI:0.82~0.955)。
临床应用与阅片要点
- 影像组学标签模型可作为区分浸润性腺癌与微浸润性腺癌的参考工具。
- 联合CT形态学特征(病灶形状)构建的列线图可能为临床决策提供信息。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: A nomogram model was developed to predict the histological subtypes of lung invasive adenocarcinomas (IAs) and minimally invasive adenocarcinomas (MIAs) that manifest as part-solid ground-glass nodules (GGNs).
MATERIALS AND METHODS: This retrospective study enrolled 119 patients with histopathologically confirmed part-solid GGNs assigned to the training (n=83) or testing cohorts (n=36). Radiomic features were extracted based on the unenhanced computed tomography (CT) images. R software was applied to process the qualitative and quantitative data. The CT features model, radiomic signature model, and combined prediction model were constructed and compared.
RESULTS: A total of 396 radiomic features were extracted from the preoperative CT images, four features including MaxIntensity, RMS, ZonePercentage, and LongRunEmphasis_angle0_offset7 were indicated to be the best discriminators to establish the radiomic signature model. The performance of the model was satisfactory in both the training and testing set with areas under the curve (AUCs) of 0.854 (95% confidence interval [CI]: 0.774 to 0.934) and 0.813 (95% CI: 0.670 to 0.955), respectively. The CT morphology of the lesion shape and diameter of the solid component were confirmed to be a significant feature for building the CT features model, which had an AUC of 0.755 (95% CI: 0.648 to 0.843). A nomogram that integrated lesion shape and radiomic signature was constructed, which contributed an AUC of 0.888 (95% CI: 0.82 to 0.955).
CONCLUSIONS: The radiomic signature could provide an important reference for differentiating IAs from MIAs, and could be significantly enhanced by the addition of CT morphology. The nomogram may be highly informative for making clinical decisions.
引用
- Weng Q, Zhou L, Wang H, et al. A radiomics model for determining the invasiveness of solitary pulmonary nodules that manifest as part-solid nodules. Clin Radiol. 2019. PMID: 31521324. doi:10.1016/j.crad.2019.07.026
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。